Summary
RS-232C control protocol for the Viewsonic CDX5562-series commercial display / digital signage. Specifies 9-byte framed Set/Get command packets, fixed 9600 8N1 serial, DSUB 9-pin (or 2.5 mm barrel) connection, and an IR pass-through mode that forwards RCU key codes to the host.
Transport
protocols:
- serial
serial:
baud_rate: 9600 # source: "9600bps (fixed)"
data_bits: 8 # source: "8 bits (fixed)"
parity: none # source: "Parity: None (fixed)"
stop_bits: 1 # source: "Stop Bits: 1 (fixed)"
flow_control: none # UNRESOLVED: flow control not stated in source
connector: DSUB-9 male # source: "DSUB 9-Pin Male"; 2.5 mm barrel documented as special case
cable: null-modem (crossover) # source: "Use of crossover (null modem) cable required"
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # inferred: power on/off commands present
- routable # inferred: input-select commands present
- queryable # inferred: Get-Function queries present
- levelable # inferred: volume/brightness/contrast/treble/bass control present
Actions
All Set/Get commands share the same 9-byte frame:
Length ID Type Command Value1 Value2 Value3 CR
0x38 0x3n m 0x67/0x73 0xnn 0x3n 0x3n 0x3n 0x0D
Where Length is the ASCII byte 0x38 (the digit "8"); ID is two ASCII digits "01"–"98" (broadcast "99" receives no reply); Type is "s" (0x73) for Set or "g" (0x67) for Get; Command is one ASCII byte; Value[1..3] is three ASCII bytes (Set) or "000" (Get); CR is 0x0D. Set reply is 5 bytes: 0x34 ID "+"|"-" 0x0D. Get reply is 9 bytes: 0x38 ID "r"|"-" Command V1 V2 V3 0x0D. Acknowledgement is "+" (0x2B), rejection is "-" (0x2D).
Example (Set Brightness = 76 on display ID 02): bytes 38 30 32 73 24 30 37 36 0D.
# --- Set-Function commands (command type "s") ---
- id: set_power
label: Power On/Off (Standby)
kind: action
command: "8{id}s!{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID ("01"-"98"; "99" = broadcast, no reply)
- name: value
type: string
description: Three ASCII bytes - "000" = STBY, "001" = ON
notes: Command code ASCII "!" (0x21). Source: "Power on/off (standby)".
- id: set_input_select
label: Input Select
kind: action
command: "8{id}s\"{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - 000:TV, 001:AV, 002:S-Video, 003:YPbPr,
004:HDMI1, 014:HDMI2, 024:HDMI3, 034:HDMI4, 005:DVI,
006:VGA1, 016:VGA2, 026:VGA3, 007:Slot-in PC (OPS/SDM)/HDBT,
008:Internal memory, 009:DP, 00A:Embedded/Main (Android).
Source notes the 2nd digit of duplicate source codes flags an extension.
notes: Command code ASCII '"' (0x22).
- id: set_brightness
label: Brightness
kind: action
command: "8{id}s${value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "$" (0x24).
- id: set_power_lock
label: Power Lock
kind: action
command: "8{id}s4{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000" = Unlock, "001" = Lock
notes: Command code ASCII "4" (0x34). Source: "*See note in details".
- id: set_volume
label: Volume
kind: action
command: "8{id}s5{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - "000"-"100" for absolute level,
"900" = Volume down (-1), "901" = Volume up (+1)
notes: Command code ASCII "5" (0x35).
- id: set_mute
label: Mute
kind: action
command: "8{id}s6{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000" = OFF, "001" = ON (mute)
notes: Command code ASCII "6" (0x36).
- id: set_button_lock
label: Button Lock
kind: action
command: "8{id}s8{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000" = Unlock, "001" = Lock
notes: Command code ASCII "8" (0x38). Source: "*See note in details".
- id: set_menu_lock
label: Menu Lock
kind: action
command: "8{id}s>{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000" = Unlock, "001" = Lock
notes: Command code ASCII ">" (0x3E). Source: "*See note in details".
- id: set_remote_control
label: Remote Control Mode
kind: action
command: "8{id}sB{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - "000" = Disable, "001" = Enable,
"002" = Pass-through. Pass-through: display bypasses RCU
code to connected device via RS232 but does not react itself.
notes: Command code ASCII "B" (0x42).
- id: set_contrast
label: Contrast
kind: action
command: "8{id}s#{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "#" (0x23).
- id: set_sharpness
label: Sharpness
kind: action
command: "8{id}s%{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "%" (0x25).
- id: set_color
label: Color
kind: action
command: "8{id}s&{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "&" (0x26).
- id: set_tint
label: Tint
kind: action
command: "8{id}s'{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "'" (0x27).
- id: set_color_mode
label: Color Mode
kind: action
command: "8{id}s){value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=Normal, "001"=Warm, "002"=Cold, "003"=Personal
notes: Command code ASCII ")" (0x29).
- id: set_surround_sound
label: Surround Sound
kind: action
command: "8{id}s-{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000" = Off, "001" = On
notes: Command code ASCII "-" (0x2D).
- id: set_bass
label: Bass
kind: action
command: "8{id}s.{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "." (0x2E).
- id: set_treble
label: Treble
kind: action
command: "8{id}s/{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100"
notes: Command code ASCII "/" (0x2F).
- id: set_balance
label: Balance
kind: action
command: "8{id}s0{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"100" (050 = central)
notes: Command code ASCII "0" (0x30).
- id: set_picture_size
label: Picture Size
kind: action
command: "8{id}s1{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=FULL (16:9), "001"=NORMAL (4:3), "002"=REAL (1:1). Source marks REAL as "3.1.0".
notes: Command code ASCII "1" (0x31).
- id: set_osd_language
label: OSD Language
kind: action
command: "8{id}s2{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=English, "001"=French, "002"=Spanish (model-dependent extension)
notes: Command code ASCII "2" (0x32).
- id: set_pip_mode
label: PIP Mode
kind: action
command: "8{id}s9{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=OFF, "001"=PIP (POP), "002"=PBP
notes: Command code ASCII "9" (0x39).
- id: set_pip_sound_select
label: PIP Sound Select
kind: action
command: "8{id}s:{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=Main, "001"=PIP (POP)
notes: Command code ASCII ":" (0x3A).
- id: set_pip_position
label: PIP Position
kind: action
command: "8{id}s;{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=Up, "001"=Down, "002"=Left, "003"=Right
notes: Command code ASCII ";" (0x3B).
- id: set_pip_input
label: PIP Input
kind: action
command: "8{id}s7{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - same code table as set_input_select
notes: Command code ASCII "7" (0x37). Source marks command as "37*2.9" (likely a version note).
- id: set_number
label: Number
kind: action
command: "8{id}s@{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "000"-"009"
notes: Command code ASCII "@" (0x40).
- id: set_keypad
label: Key Pad
kind: action
command: "8{id}sA{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - "000"=UP, "001"=DOWN, "002"=LEFT,
"003"=RIGHT, "004"=ENTER, "005"=INPUT, "006"=MENU/(EXIT),
"007"=EXIT
notes: Command code ASCII "A" (0x41).
- id: set_tiling_mode
label: Tiling Mode (video wall)
kind: action
command: "8{id}sP{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=OFF, "001"=ON
notes: Command code ASCII "P" (0x50).
- id: set_tiling_compensation
label: Tiling Compensation (bezel width)
kind: action
command: "8{id}sQ{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - "000"=OFF, "001"=ON
notes: Command code ASCII "Q" (0x51).
- id: set_tiling_h_by_v
label: Tiling H by V Monitors
kind: action
command: "8{id}sR{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - 2nd digit is H monitor count
("1"-"9"), 3rd digit is V monitor count ("1"-"9").
Example "132" = 1 H x 3 V.
notes: Command code ASCII "R" (0x52).
- id: set_tiling_position
label: Tiling Position
kind: action
command: "8{id}sS{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes, "001"-"025" - screen position to copy to the addressed display
notes: Command code ASCII "S" (0x53).
- id: set_date
label: Date (Year/Month/Day)
kind: action
command: "8{id}sV{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - prefix with field tag then 2 digits:
Y17-Y99 for Year (last 2 digits of 20YY),
M01-M12 for Month, D01-D31 for Day.
notes: Command code ASCII "V" (0x56).
- id: set_time
label: Time (Hour/Min/Sec)
kind: action
command: "8{id}sW{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: |
Three ASCII bytes - prefix with field tag then 2 digits:
H00-H23 (24-hr Hour), M00-M59 (Minute), S00-S59 (Second).
notes: Command code ASCII "W" (0x57).
# --- Get-Function commands (command type "g") ---
- id: get_contrast
label: Get Contrast
kind: query
command: "8{id}ga0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "a" (0x61). Response value range "000"-"100".
- id: get_brightness
label: Get Brightness
kind: query
command: "8{id}gb0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "b" (0x62). Response value range "000"-"100".
- id: get_sharpness
label: Get Sharpness
kind: query
command: "8{id}gc0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "c" (0x63). Response value range "000"-"100".
- id: get_color
label: Get Color
kind: query
command: "8{id}gd0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "d" (0x64). Response value range "000"-"100".
- id: get_tint
label: Get Tint
kind: query
command: "8{id}ge0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "e" (0x65). Response value range "000"-"100".
- id: get_volume
label: Get Volume
kind: query
command: "8{id}gf0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "f" (0x66). Response value range "000"-"100".
- id: get_mute
label: Get Mute
kind: query
command: "8{id}gg0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "g" (0x67). Response "000"=OFF, "001"=ON.
- id: get_input_select
label: Get Input Select
kind: query
command: "8{id}gj0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "j" (0x6A). Response range per set_input_select table (source truncated at "000~").
- id: get_power_status
label: Get Power Status (ON/STBY)
kind: query
command: "8{id}gl0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "l" (0x6C). Response "000"=STBY, "001"=ON.
- id: get_remote_control
label: Get Remote Control Mode
kind: query
command: "8{id}gn0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "n" (0x6E). Response "000"=Disable, "001"=Enable, "002"=Pass-through.
- id: get_power_lock
label: Get Power Lock
kind: query
command: "8{id}go0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "o" (0x6F). Response "000"=Unlock, "001"=Lock.
- id: get_button_lock
label: Get Button Lock
kind: query
command: "8{id}gp0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "p" (0x70). Response "000"=Unlock, "001"=Lock.
- id: get_menu_lock
label: Get Menu Lock
kind: query
command: "8{id}gq0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "q" (0x71). Response "000"=Unlock, "001"=Lock.
- id: get_pip_mode
label: Get PIP Mode
kind: query
command: "8{id}gt0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "t" (0x74). Response "000"=OFF, "001"=PIP (POP), "002"=PBP.
- id: get_pip_input
label: Get PIP Input
kind: query
command: "8{id}gu0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "u" (0x75). Response range per set_input_select table (source truncated at "000 ~").
- id: get_tiling_mode
label: Get Tiling Mode
kind: query
command: "8{id}gv0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "v" (0x76). Response "000"=OFF, "001"=ON.
- id: get_tiling_compensation
label: Get Tiling Compensation
kind: query
command: "8{id}gw0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "w" (0x77). Response "000"=OFF, "001"=ON.
- id: get_tiling_h_by_v
label: Get Tiling H by V Monitors
kind: query
command: "8{id}gx0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: |
Command code ASCII "x" (0x78). Response: 2nd digit = H monitors
"1"-"9", 3rd digit = V monitors "1"-"9".
- id: get_tiling_position
label: Get Tiling Position
kind: query
command: "8{id}gy0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "y" (0x79). Response "000"=OFF, "001"-"025"=position.
- id: get_ack
label: Get ACK (link test)
kind: query
command: "8{id}gz0000x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
notes: Command code ASCII "z" (0x7A). Used to test the communication link. Response always "000".
- id: get_thermal
label: Get Thermal (temperature)
kind: query
command: "8{id}g0{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - typically "000"
notes: |
Command code ASCII "0" (0x30). Specific models only.
Response "000"-"100" = 0 to +100 deg C, "-01" to "-99" = -1 to -99 deg C.
- id: get_power_on_off_log
label: Get Power On/Off Log
kind: query
command: "8{id}g1{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - typically "000"
notes: Command code ASCII "1" (0x31). Specific models only. Response format referenced by source note.
- id: get_date
label: Get Date (Year/Month/Day)
kind: query
command: "8{id}g2{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - typically "000"
notes: |
Command code ASCII "2" (0x32). Specific models only.
Response prefix indicates field: "Y17"-"Y99" Year, "M01"-"M12" Month,
"D01"-"D31" Day.
- id: get_time
label: Get Time (Hour/Min/Sec)
kind: query
command: "8{id}g3{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - typically "000"
notes: |
Command code ASCII "3" (0x33). Specific models only.
Response prefix indicates field: "H00"-"H23" Hour, "M00"-"M59" Minute,
"S00"-"S59" Second.
- id: get_rs232_version
label: Get RS232 Protocol Version
kind: query
command: "8{id}g6{value}0x0D"
params:
- name: id
type: string
description: Two-ASCII-digit display ID
- name: value
type: string
description: Three ASCII bytes - typically "000"
notes: |
Command code ASCII "6" (0x36). Response range "001~" - version
formatted as "0.0.1" through "9.9.9".
Feedbacks
- id: power_state
type: enum
values: [stby, on]
source: get_power_status
- id: mute_state
type: enum
values: [off, on]
source: get_mute
- id: input_source
type: string
description: |
Three-ASCII-byte code per set_input_select table (000/001/002/003/004/014/024/034/005/006/016/026/007/008/009/00A).
source: get_input_select
- id: remote_control_mode
type: enum
values: [disable, enable, pass_through]
source: get_remote_control
- id: lock_state
type: enum
values: [unlock, lock]
source: get_power_lock / get_button_lock / get_menu_lock
- id: tiling_mode_state
type: enum
values: [off, on]
source: get_tiling_mode
- id: tiling_compensation_state
type: enum
values: [off, on]
source: get_tiling_compensation
- id: tiling_geometry
type: string
description: Three ASCII bytes - 2nd digit H monitors (1-9), 3rd digit V monitors (1-9)
source: get_tiling_h_by_v
- id: tiling_position_state
type: string
description: "000"=OFF or "001"-"025" position
source: get_tiling_position
- id: pip_mode_state
type: enum
values: [off, pip_pop, pbp]
source: get_pip_mode
- id: pip_input_state
type: string
description: Three-ASCII-byte code per set_input_select table
source: get_pip_input
- id: ack_link
type: string
description: Always "000" when link is healthy
source: get_ack
- id: thermal_celsius
type: integer
description: |
0-100 from response "000"-"100"; negative 1-99 from response "-01"-"-99".
Specific models only.
source: get_thermal
- id: rs232_version
type: string
description: Protocol version string in 0.0.1 - 9.9.9 format
source: get_rs232_version
- id: set_command_ack
type: enum
values: [valid, invalid]
description: |
Valid (Command Type "+", 0x2B) or invalid (Command Type "-", 0x2D)
reply to any Set command. Reply is 5 bytes: 0x34 ID 0x2B|0x2D 0x0D.
source: set-command reply
- id: ir_pass_through_key
type: string
description: |
Unsolicited 7-byte packet (Command Type "p", 0x70) sent when the
display is in Remote Control Pass-through mode. Packet layout:
0x36 ID 0x70 RCU_Code1 RCU_Code2 0x0D. RCU_Code2 is the MSB,
RCU_Code1 the LSB. See the IR code table in the source document
for the full key-to-code map (1=0x01 ... 0=0x0A, VOL+=0x10,
VOL-=0x11, MUTE=0x12, POWER=0x15, SOURCES=0x16, MENU=0x1A,
UP=0x1B, DOWN=0x1C, LEFT=0x1D, RIGHT=0x1E, OK=0x1F, EXIT=0x20,
RED/F1=0x2C, GREEN/F2=0x2D, YELLOW/F3=0x2E, BLUE/F4=0x2F, ...).
source: IR pass-through reply
Variables
- id: contrast
type: integer
range: [0, 100]
description: Contrast level
source: get_contrast / set_contrast
- id: brightness
type: integer
range: [0, 100]
description: Brightness level
source: get_brightness / set_brightness
- id: sharpness
type: integer
range: [0, 100]
description: Sharpness level
source: get_sharpness / set_sharpness
- id: color
type: integer
range: [0, 100]
description: Color saturation level
source: get_color / set_color
- id: tint
type: integer
range: [0, 100]
description: Tint level
source: get_tint / set_tint
- id: volume
type: integer
range: [0, 100]
description: |
Volume level. Use set_volume values 900/901 for relative -1/+1 steps.
source: get_volume / set_volume
- id: bass
type: integer
range: [0, 100]
source: set_bass
- id: treble
type: integer
range: [0, 100]
source: set_treble
- id: balance
type: integer
range: [0, 100]
description: 050 = central
source: set_balance
- id: color_mode
type: enum
values: [normal, warm, cold, personal]
source: set_color_mode
- id: surround_sound
type: enum
values: [off, on]
source: set_surround_sound
- id: picture_size
type: enum
values: [full_16_9, normal_4_3, real_1_1]
source: set_picture_size
- id: osd_language
type: enum
values: [english, french, spanish]
description: Model-dependent - may be extended
source: set_osd_language
- id: date
type: object
description: |
Year/Month/Day, each field a 2-digit decimal. Set/get via single
command code (sV / g2) with a Y/M/D prefix in the value/response.
fields: [year, month, day]
source: set_date / get_date
- id: time
type: object
description: |
Hour (00-23, 24-hr)/Minute(00-59)/Second(00-59). Set/get via
single command code (sW / g3) with a H/M/S prefix in the
value/response.
fields: [hour, minute, second]
source: set_time / get_time
- id: number_input
type: integer
range: [0, 9]
description: Numeric keypad entry 000-009
source: set_number
Events
- id: ir_pass_through
description: |
When the display is in Remote Control Pass-through mode (set via
set_remote_control value 002), the display forwards every RCU key
press to the host as a 7-byte packet:
0x36 ID 0x70 RCU_MSB RCU_LSB 0x0D
where ID is the display ID and the two RCU bytes encode the
pressed key (see source IR code table). POWER key has a special
sequence - see Safety section.
packet_format: "0x36 {id} 0x70 {rcu_msb} {rcu_lsb} 0x0D"
- id: set_command_reply
description: |
Every Set command produces a 5-byte reply:
0x34 ID 0x2B 0x0D (valid, "+" = 0x2B)
0x34 ID 0x2D 0x0D (invalid, "-" = 0x2D)
packet_format: "0x34 {id} 0x2B|0x2D 0x0D"
- id: get_command_reply
description: |
Every Get command produces a 9-byte reply on success (Command
Type "r", 0x72): 0x38 ID 0x72 CMD V1 V2 V3 0x0D. On error the
reply collapses to 5 bytes: 0x34 ID 0x2D 0x0D ("-" = invalid).
packet_format: "0x38 {id} 0x72 {cmd} {v1} {v2} {v3} 0x0D"
Macros
# Multi-step sequences described explicitly in source.
# UNRESOLVED: source does not document composite macros; only single-command
# Set/Get functions and the IR pass-through mode are specified. IR press-and-hold
# for VOLUME UP/DOWN "will repeatedly output when you press and hold the keys"
# is the only multi-frame behaviour noted (treat as repeated single-key events).
Safety
confirmation_required_for:
- set_power # source: power on/off (standby)
interlocks:
- id: power_lock
description: |
When set_power_lock is enabled (value 001), the display ignores the
POWER key. IR pass-through of the POWER key is also suppressed in
this state.
source: set_power_lock; IR pass-through note 2-3
- id: power_ir_sequence
description: |
In IR pass-through mode, POWER has a special two-step sequence:
(a) display OFF + IR POWER -> display turns ON, then forwards POWER
code to host;
(b) display ON + IR POWER -> display forwards POWER code to host,
then turns OFF.
The PC host receives the POWER code in both cases and can decide
whether to keep the display on.
source: IR pass-through note 2-1, 2-2
# UNRESOLVED: source contains no electrical-safety, fire, or shock warnings;
# no firmware downgrade or recovery procedure is documented.
Notes
Command frame (9 bytes). Every Set and Get command follows the layout Length ID Type Command V1 V2 V3 CR where Length is the literal ASCII byte 0x38 (digit "8"), ID is two ASCII digits "01"–"98", Type is "s" / "g" / "+" / "-" / "r" / "p", Command is one ASCII byte per the tables, V1–V3 are three ASCII bytes, and CR is 0x0D. Get sends V1–V3 as "000"; the response echoes the actual value. Set reply is 5 bytes; Get reply is 9 bytes (or 5 bytes on error).
ID 99 broadcast. Sending to ID "99" writes all displays; no reply is generated. With multiple displays, only the unit with ID "01" is required to acknowledge on the host's behalf.
Source table duplication. The Get-Function tables list four commands (contrast/sharpness/color/tint) in both the "Basic function" and "Optional function" tables with identical opcodes. They are the same commands; the spec lists them once each. The same is true of the four tiling Get commands (mode/compensation/H-by-V/position), which also appear in both tables.
Set-Date / Set-Time are single commands with field-tagged values. The Set-Date Year/Month/Day and Set-Time Hour/Min/Sec each use a single command code (V / W) with a Y/M/D or H/M/S prefix in the value bytes. The spec exposes them as one action with the prefix documented in params.
Exceptions for VT2405LED-1 and VT3205LED. The source notes that those models (not part of the CDX5562 series) have a different "Power on" reply (0x32 0x2B 0x0D = "2+<CR>") and a different "Power STBY status" reply (0x36 0x72 0x6C 0x30 0x30 0x30 0x0D = "6rl000<CR>"). These exceptions are not applicable to the CDX5562 series and are listed here only for completeness.
Cable and connector. Source specifies a crossover (null-modem) DB9 cable, male connector on the display. A 2.5 mm barrel connector variant is documented as a special case with tip=TXD, ring=RXD, sleeve=GND.
Volume relative steps. Volume "900" decrements by 1 and "901" increments by 1; absolute volume is "000"–"100".
Tiling H-by-V value format. The 2nd ASCII digit of the value specifies H monitor count and the 3rd digit specifies V monitor count, each "1"–"9". Example "132" = 1 H x 3 V.
Provenance
source_domains:
- viewsonicglobal.com
- manualslib.com
- viewsonic.com
source_urls:
- https://www.viewsonicglobal.com/public/products_download/user_guide/CD/CDX5560_CDX5562/CDX5560_CDX5562_UG_ENG.pdf
- "https://www.manualslib.com/manual/3900742/Viewsonic-Cdx5562.html#manual"
- https://www.viewsonic.com/us/cdx5562.html
retrieved_at: 2026-04-29T10:24:07.729Z
last_checked_at: 2026-06-02T22:16:08.457Z
Verification Summary
verdict: verified
checked_at: 2026-06-02T22:16:08.457Z
matched_actions: 57
action_count: 57
confidence: medium
summary: "All 57 spec actions traced to source (dip-safe re-verify). (5 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "firmware version compatibility not stated; model-family coverage (e.g. CDX5562 vs CDX5562-1 sub-variants) not enumerated beyond product label."
- "flow control not stated in source"
- "source does not document composite macros; only single-command"
- "source contains no electrical-safety, fire, or shock warnings;"
- "firmware version compatibility not stated in source; per-model availability of get_thermal / get_power_on_off_log / get_date / get_time is flagged in source as \"For specific models only\" but the model list is not enumerated; flow control (RTS/CTS, XON/XOFF) is not stated; maximum packet rate / inter-frame timing is not stated."