Summary
Broadcast audio delay system supporting RS-232/RS-485 serial control and TCP/IP network control via port 5443. Web interface on port 80 with Adobe Flash GUI on port 5444. Parallel GPIO via DB-25. Bi-directional data delay streams on ports 5445–5448. Commands are ASCII, case-sensitive, terminated by <LF>. Responses use ! (success) or ? (error) prefixes. No password on port 5443; web interface uses pdmweb/password auth.
Transport
protocols:
- tcp
- serial
addressing:
port: 5443 # TCP command port; no password required on this port
base_url: http:// # Web interface on port 80
serial:
baud_rate: null # UNRESOLVED: baud rate configurable 1200-115200, no default stated in source
data_bits: null
parity: null
stop_bits: null
auth:
tcp:
type: none # inferred: source explicitly states "no further password checking" on port 5443
http:
type: password
credentials:
username: pdmweb
password: pdmwebBnnn # default; Bnnn = module code from Information screen
serial:
type: none # inferred: no auth procedure for serial in source
Traits
- queryable # inferred from get Depth, get PeakInput, get PeakOutput, get TemperatureC/F examples
- routable # inferred: input/output routing via data delay streams (ports 5445-5448)
Actions
- id: down
label: Down
kind: action
params:
- name: argument
type: string
description: Event name (Build, Exit, Cough, Dump, Bypass, Cue1-Cue8, Flag1-Flag8)
- id: up
label: Up
kind: action
params:
- name: argument
type: string
description: Event name
- id: trigger
label: Trigger
kind: action
params:
- name: argument
type: string
description: Momentary activation of argument (same as down+up)
- id: get
label: Get
kind: action
params:
- name: variable
type: string
description: Variable to query (Depth, PeakInput, PeakOutput, TemperatureC, TemperatureF)
- id: help
label: Help
kind: action
params: []
- id: help_command
label: Help Command
kind: action
params:
- name: command
type: string
description: Specific command to get help for
- id: enable
label: Enable
kind: action
params:
- name: event
type: string
description: EventName(s) to enable reporting; use "All" for all events
- id: disable
label: Disable
kind: action
params:
- name: event
type: string
description: EventName(s) to disable reporting; use "All" for all
Feedbacks
- id: command_success
type: enum
values:
- "!"
description: "PDM acknowledges command received and acted upon"
- id: command_error
type: enum
values:
- "?"
description: "PDM doesn't understand command or cannot act upon it"
- id: output_event
type: string
description: "Event message format: @NameOfEvent[=1 or =0]<LF>. Boolean absent for momentary events."
variables:
- DelaySafe
- DelayFull
- DelayEmpty
- DelayUnsafe
- Bypass
- Muted
- Building
- Exiting
- BuildTrig
- DumpTrig
- EmptyTrig
- FullTrig
- Cue1-Cue8
- Flag1-Flag8
- BuildLamp
- ExitLamp
- DumpLamp
- CoughLamp
- All
- id: welcome
type: string
description: "@Welcome to PDM xxxx<LF> sent on boot or socket connection (xxxx = serial number)"
Variables
- id: Depth
type: number
unit: seconds
description: Current audio delay length in seconds and tenths
- id: PeakInput
type: number
unit: dBFS
description: Peak input level, both channels
- id: PeakOutput
type: number
unit: dBFS
description: Peak output level, both channels
- id: TemperatureC
type: number
unit: degrees Celsius
description: Internal temperature in whole degrees Celsius
- id: TemperatureF
type: number
unit: degrees Fahrenheit
description: Internal temperature in whole degrees Fahrenheit
Events
# PDM sends unsolicited Output Events when enabled.
# Boolean =1 or =0 sent only for ongoing states; absent for momentary events.
- id: DelaySafe
type: boolean
description: Memory now has enough audio to cover at least one complete dump
- id: DelayFull
type: boolean
description: Delay memory is now full
- id: DelayEmpty
type: boolean
description: Memory is empty
- id: DelayUnsafe
type: boolean
description: Memory contains audio but not full dump increment
- id: Bypass
type: boolean
description: PDM is in bypass mode
- id: Muted
type: boolean
description: PDM output is muted
- id: Building
type: boolean
description: PDM is building up a delay
- id: Exiting
type: boolean
description: PDM is exiting a delay
- id: BuildTrig
type: momentary
description: BUILD button pressed
- id: DumpTrig
type: momentary
description: DUMP button pressed
- id: EmptyTrig
type: momentary
description: Memory just completely emptied
- id: FullTrig
type: momentary
description: Memory just completely filled
- id: Cue1-Cue8
type: momentary
description: Cue point n reached
- id: Flag1-Flag8
type: boolean
description: Flag point n state
- id: BuildLamp
type: boolean
description: BUILD button lamp state
- id: ExitLamp
type: boolean
description: EXIT button lamp state
- id: DumpLamp
type: boolean
description: DUMP button lamp state
- id: CoughLamp
type: boolean
description: COUGH button lamp state
Macros
# UNRESOLVED: no explicit multi-step macros described in source
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings or interlock procedures stated in source
Notes
- Port 5443 TCP has no password after connection — source warns: "Use a firewall, or keep your PDM on a dedicated (closed) network, for protection."
- Web interface (port 80) uses
pdmweb/password auth; default password ispdmwebBnnn(Bnnn = module code from Information screen). - RS-232 can serve only one function at a time: either control OR data delay, not both.
- Data delay streams: Stream A input port 5445, Stream B input port 5446; Stream A output port 5447, Stream B output port 5448.
- RS-232 TX/RX on DB-25 pins 2/3. RS-485 differential on pins 8–12.
- Carriage Return (ASCII 13) is ignored by the system; Line Feed (ASCII 10) terminates commands.
- Commands are case-sensitive, all lower-case.
- GPIO trigger pulse length configurable 100–1000 ms (default 250 ms) in Hardware GPIO configuration.
- Cue marks generate 250 ms triggers (configurable 100–1000 ms); Flag marks reflect continuous logic state.
Provenance
source_domains:
- telosalliance-uat.s3.amazonaws.com
source_urls:
- https://telosalliance-uat.s3.amazonaws.com/public/25-Seven/PDM/25Seven-Manual-PDM-2.4a-C1914012.pdf
retrieved_at: 2026-04-30T01:59:33.876Z
last_checked_at: 2026-06-02T22:15:40.601Z
Verification Summary
verdict: verified
checked_at: 2026-06-02T22:15:40.601Z
matched_actions: 8
action_count: 8
confidence: medium
summary: "All 8 spec actions traced to source (dip-safe re-verify). (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "RS-232 baud rate not stated in source (source only says \"choose standard values between 1200 and 115200 baud\")"
- "baud rate configurable 1200-115200, no default stated in source"
- "no explicit multi-step macros described in source"
- "no safety warnings or interlock procedures stated in source"
- "RS-232 baud rate, data bits, parity, stop bits not stated in source (configurable 1200–115200 only)"
- "firmware version not stated in source"
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0