SymNet Composer v2.0 control protocol for Symetrix Prism Series DSPs (and other Composer-based units: Edge, Radius, Radius AEC, xControl). Provides ASCII text command/response control over RS-232, TCP/IP, and UDP/IP. Commands reference user-assigned controller numbers defined in SymNet Composer software.
Transport
protocols:
- serial
- tcp
- udp
addressing:
port: 48631
serial:
baud_rate: 57600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # inferred: unit supports reboot via R! command; not a literal power on/off command in source
- routable # inferred: input/output selector controllers documented
- queryable # inferred: GS, GSB, GPR, GSYSS, RI, V query commands present
- levelable # inferred: fader/volume controller commands documented
Actions
# CRITICAL: each named opcode in the source = one action. Parameter ranges
# (e.g. CS controller position 0-65535) do not multiply into separate actions.
- id: controller_set
label: Controller Set (CS)
kind: action
command: "CS {controller_number} {controller_position}"
params:
- name: controller_number
type: integer
description: Decimal controller number (1-10000) assigned in SymNet Composer
- name: controller_position
type: integer
description: 16-bit value (0-65535)
- id: controller_change
label: Change Controller (CC)
kind: action
command: "CC {controller_number} {dec_inc} {amount}"
params:
- name: controller_number
type: integer
description: Decimal controller number (1-10000)
- name: dec_inc
type: integer
description: 0 = decrement, 1 = increment
- name: amount
type: integer
description: Increment/decrement amount (0-65535)
- id: get_controller
label: Get Controller (GS)
kind: query
command: "GS {controller_number}"
params:
- name: controller_number
type: integer
description: Decimal controller number (1-10000)
- id: get_controller_with_number
label: Get Controller with Controller Number (GS2)
kind: query
command: "GS2 {controller_number}"
params:
- name: controller_number
type: integer
description: Decimal controller number (1-10000)
- id: get_preset
label: Get Preset (GPR)
kind: query
command: "GPR"
- id: get_controller_block
label: Get Controller Block (GSB)
kind: query
command: "GSB {controller_number} {block_size}"
params:
- name: controller_number
type: integer
description: Starting decimal controller number (1-10000)
- name: block_size
type: integer
description: Number of consecutive controllers (max 256)
- id: get_controller_block_with_number
label: Get Controller Block with Controller Number (GSB2)
kind: query
command: "GSB2 {controller_number} {block_size}"
params:
- name: controller_number
type: integer
description: Starting decimal controller number (1-10000)
- name: block_size
type: integer
description: Number of consecutive controllers (max 256)
- id: get_controller_block_with_number_echo
label: Get Controller Block with Controller Number, Echo (GSB3)
kind: query
command: "GSB3 {controller_number} {block_size}"
params:
- name: controller_number
type: integer
description: Starting decimal controller number (1-10000)
- name: block_size
type: integer
description: Number of consecutive controllers (max 256)
- id: load_preset
label: Load Preset (LP)
kind: action
command: "LP {preset_number}"
params:
- name: preset_number
type: integer
description: Preset number (1-1000)
- id: flash_unit_leds
label: Flash Unit LEDs (FU)
kind: action
command: "FU [{cycles}]"
params:
- name: cycles
type: integer
description: Number of on/off cycles; 0 halts flashing; default 8
- id: set_system_string
label: Set System String (SSYSS)
kind: action
command: "SSYSS {unit}.{resource}.{enum}.{card}.{channel}={value}"
params:
- name: unit
type: integer
description: Unit enumerator (e.g. 1 for unit labeled Edge-1)
- name: resource
type: integer
description: Resource number (1000=speed dial number, 1001=speed dial name, 1004=telephone digits for direct dial)
- name: enum
type: integer
description: Zero-based enum (0-19 for speed dials 1-20)
- name: card
type: integer
description: Card slot (0-3 for A-D)
- name: channel
type: integer
description: Zero-based channel (0 where not applicable)
- name: value
type: string
description: String value to set
- id: get_system_string
label: Get System String (GSYSS)
kind: query
command: "GSYSS {unit}.{resource}.{enum}.{card}.{channel}"
params:
- name: unit
type: integer
description: Unit enumerator
- name: resource
type: integer
description: Resource number (1000-1006)
- name: enum
type: integer
description: Zero-based enum (0-19 for speed dials)
- name: card
type: integer
description: Card slot (0-3 for A-D)
- name: channel
type: integer
description: Zero-based channel
- id: push_global_enable_disable
label: Global Push Enable/Disable (PU)
kind: action
command: "PU {on_off} [{low} [{high}]]"
params:
- name: on_off
type: integer
description: 0=OFF, 1=ON
- name: low
type: integer
description: Optional lowest controller number (1-10000)
- name: high
type: integer
description: Optional highest controller number (1-10000)
- id: push_enable
label: Push Enable (PUE)
kind: action
command: "PUE [{low} [{high}]]"
params:
- name: low
type: integer
description: Optional lowest controller number (1-10000)
- name: high
type: integer
description: Optional highest controller number (1-10000)
- id: push_disable
label: Push Disable (PUD)
kind: action
command: "PUD [{low} [{high}]]"
params:
- name: low
type: integer
description: Optional lowest controller number (1-10000)
- name: high
type: integer
description: Optional highest controller number (1-10000)
- id: get_push_enabled_controllers
label: Get Push-enabled Controllers (GPU)
kind: query
command: "GPU [{low} [{high}]]"
params:
- name: low
type: integer
description: Optional lowest controller number (1-10000)
- name: high
type: integer
description: Optional highest controller number (1-10000)
- id: push_refresh
label: Push Refresh (PUR)
kind: action
command: "PUR [{low} [{high}]]"
params:
- name: low
type: integer
description: Optional lowest controller number (1-10000)
- name: high
type: integer
description: Optional highest controller number (1-10000)
- id: push_clear
label: Push Clear (PUC)
kind: action
command: "PUC [{low} [{high}]]"
params:
- name: low
type: integer
description: Optional lowest controller number (1-10000)
- name: high
type: integer
description: Optional highest controller number (1-10000)
- id: set_push_interval
label: Set Push Interval (PUI)
kind: action
command: "PUI {milliseconds}"
params:
- name: milliseconds
type: integer
description: Push interval in ms (20-30000)
- id: set_push_threshold
label: Set Push Threshold (PUT)
kind: action
command: "PUT [{parameter_thresh} [{meter_thresh}]]"
params:
- name: parameter_thresh
type: integer
description: Optional parameter threshold (0-65535)
- name: meter_thresh
type: integer
description: Optional meter threshold (0-65535)
- id: set_baud
label: Set Baud (SB)
kind: action
command: "SB {baud}"
params:
- name: baud
type: integer
description: Baud rate; one of 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
- id: set_quiet_mode
label: Set Quiet Mode (SQ)
kind: action
command: "SQ {on_off}"
params:
- name: on_off
type: integer
description: 0=OFF, 1=ON
- id: set_echo_mode
label: Set Echo Mode (EH)
kind: action
command: "EH {on_off}"
params:
- name: on_off
type: integer
description: 0=OFF, 1=ON
- id: nop
label: NOP (No Operation)
kind: action
command: "NOP"
- id: quit_tcp_session
label: Quit TCP/IP Session (Q!)
kind: action
command: "Q!"
- id: get_ip_address
label: Get IP Address (RI)
kind: query
command: "RI"
- id: get_version
label: Get Version (V)
kind: query
command: "V"
- id: reboot
label: Reboot Device (R!)
kind: action
command: "R!"
- id: prefix_echo
label: Echo Mode Prefix ($e)
kind: action
command: "$e {command}"
params:
- name: command
type: string
description: Command to execute with one-time echo
- id: prefix_verbose
label: Verbose Mode Prefix ($v)
kind: action
command: "$v {command}"
params:
- name: command
type: string
description: Command to execute with one-time verbose response
- id: prefix_quiet
label: Quiet Mode Prefix ($q)
kind: action
command: "$q {command}"
params:
- name: command
type: string
description: Command to execute with one-time quiet response
Feedbacks
- id: ack
label: ACK
type: string
values: ["ACK"]
- id: nak
label: NAK
type: string
values: ["NAK"]
description: Returned when command is interpreted but fails for any reason (e.g. controller number does not exist, invalid block size, Q! sent on non-TCP connection)
- id: pushed_data
label: Pushed Controller Data
type: string
description: Format "#<CONTROLLER NUMBER>=<CONTROLLER POSITION><CR>"; 5-digit zero-padded number and position; up to 64 strings per push batch
- id: push_settings
label: Push Settings (GPU 0)
type: string
description: Global=0/1 then five 5-digit values: global lower limit, global upper limit, parameter threshold, meter threshold, push interval in ms
Variables
# Per-controller 16-bit values (0-65535) interpreted according to the parameter
# type assigned in SymNet Composer (fader, button, input/output selector, meter,
# LED, ratio, frequency, width/Q, attack/release/hold, pan, delay, gain,
# threshold, depth, etc.). The mapping is site-specific.
- id: controller_value
label: Controller Position
type: integer
range: 0-65535
description: Universal 16-bit value; interpretation depends on the controller's assigned parameter type in SymNet Composer
Events
- id: pushed_change
label: Pushed Parameter Change
description: Unsolicited GSB2-format data sent out RS-232 and Ethernet (UDP+TCP) when a push-enabled controller's underlying parameter changes. Default push interval 100ms. Up to 64 strings per interval.
- id: pushed_system_string
label: Pushed System String
description: Unsolicited system string pushes (speed dial name/number changes, etc.) enabled via Tools->Site Preferences "Enable System String Pushing". Sent out RS-232 and Ethernet.
Macros
# UNRESOLVED: no explicit multi-step macro sequences documented in source.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings, interlocks, or power-on sequencing procedures
# documented in the source. Source notes the rear panel reset button erases
# accessory port settings and "should only be used as a last resort since it
# also resets many other settings" but does not document a formal safety
# procedure.
Notes
- Protocol is text/ASCII; commands terminated with carriage return (, ASCII 13). Commands may optionally include a zero-termination character on input but not on output.
- Same command syntax works identically over RS-232, TCP/IP, and UDP/IP — the Ethernet protocol is the RS-232 command protocol carried over an Ethernet network.
- TCP/IP control uses no Telnet options or escape sequences. Up to 4 concurrent TCP telnet sessions; a 5th connection evicts the least recently used session.
- UDP responses go to the last received IP:port (saved in non-volatile memory across power cycles). TCP must re-initiate after power cycle.
- RS-232 default: 57600 baud, 8 data bits, 1 stop bit, no parity, no flow control. Echo OFF, Quiet Mode ON at startup. SB/SQ/EH commands modify these at runtime; settings persist across power cycles but are overridden by the next pushed Site File.
- Push is globally enabled at power-on; individual controllers must also be enabled via PUE (or have "Enable Push" set in SymNet Composer). Baud 115200 recommended if pushing a large volume of data.
- Controller numbers 1-10000, assigned per-site in SymNet Composer. A value of 0 generally means "minimum" and 65535 means "maximum" for the assigned parameter type; 16-bit resolution is quantized to parameter granularity on read-back.
- Fader formula: Volume dB = -72 + 84 * (controller_position/65535); OFF when position=0. Generic: MIN + (MAX-MIN) * (position/65535).
- The "Firmware Version" example in the V command section shows Prism/Edge/Radius-class firmware (Dante, ARC-Web, RS-232 firmware V1.55, etc.); version example is illustrative, not authoritative for any specific unit.
- This spec is derived from the SymNet Composer v2.0 control protocol document which is shared by Edge, Radius, Radius AEC, xControl, and other Composer-based units (including Prism per vendor FAQ). Prism-specific command extensions or limitations are not documented in the source.
Provenance
source_domains:
- usermanual.wiki
- symetrixinc.com
- d3b79pswu7f4ma.cloudfront.net
- manuals.plus
source_urls:
- https://usermanual.wiki/Document/SymNetComposercp.1610368993.pdf
- https://www.symetrixinc.com/wp-content/uploads/2023/05/Symetrix_PROTOCOL_Jupiter_cp2.pdf
- https://d3b79pswu7f4ma.cloudfront.net/pdf-download/Jupiter-Control-Protocol.pdf
- https://manuals.plus/symetrix/prism-8x8-programmable-digital-signal-processor-manual.pdf
- https://manuals.plus/m/7892b80f0f9db39d2bd22283ff673072d1be514180c65f0d403de81d6549808e_optim.pdf
retrieved_at: 2026-06-12T00:06:56.335Z
last_checked_at: 2026-06-12T20:01:01.754Z
Verification Summary
verdict: verified
checked_at: 2026-06-12T20:01:01.754Z
matched_actions: 31
action_count: 31
confidence: medium
summary: "All 31 spec actions match their literal wire-level counterparts in the source; transport values (port 48631, baud 57600, 8N1, no flow control) all confirmed; source catalogue is fully represented by the spec. (4 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "Prism-specific firmware version, model subvariants, and any Prism-only command extensions not documented in the generic Composer v2.0 protocol."
- "no explicit multi-step macro sequences documented in source."
- "no safety warnings, interlocks, or power-on sequencing procedures"
- "Prism-specific model variants (e.g. Prism 4x4, Prism 8x8), firmware compatibility ranges, voltage/current/power specs, and any Prism-only command extensions."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0