Summary
The Stewart Filmscreen BRIC is a motorised masking controller for projection screens. This spec covers its RS-232C serial command set, including per-channel motor up/down/stop, nine programmable presets, and preset storage. Communication is via a fixed-format dot-delimited message on an RJ45 jack (connector J6).
Transport
protocols:
- serial
serial:
baud_rate: 19200
data_bits: 8
parity: none
stop_bits: 1
flow_control: none # source column "Hand-Shaking" = None
auth:
type: none # inferred: no auth procedure in source
Connector: RJ45 jack (J6) on BRIC controller. Pinout for DB-9 interface cable construction: Pin 1 RTS, Pin 2 CTS, Pin 3 GND, Pin 4 TX, Pin 5 GND, Pin 6 RX, Pin 7 +485, Pin 8 -485. Source does not state any port number; this is a direct-attached serial link, not a TCP port.
Traits
# Inferred from command set:
- powerable # UNRESOLVED: no explicit power on/off commands in source
- routable # UNRESOLVED: no input routing commands in source
- queryable # UNRESOLVED: no query commands in source
Actions
# All command keys from Table 1 enumerated.
# Message format: #<XX>.<YY><CR>
# where XX = unique address (factory default 01, valid 01-04 per syntax table)
# YY = command key
# <CR> = carriage return (0x0D). Source explicitly states "definitely not a LINE FEED".
- id: channel_a_up
label: Channel A Up
kind: action
command: "#{address}.UA" # followed by CR (0x0D)
params:
- name: address
type: string
description: Unique unit address. Factory default 01. Valid range 01-04 per syntax table.
default: "01"
- id: channel_b_up
label: Channel B Up
kind: action
command: "#{address}.UB"
params:
- name: address
type: string
default: "01"
- id: channel_c_up
label: Channel C Up / Close
kind: action
command: "#{address}.UC"
params:
- name: address
type: string
default: "01"
- id: channel_a_down
label: Channel A Down
kind: action
command: "#{address}.DA"
params:
- name: address
type: string
default: "01"
- id: channel_b_down
label: Channel B Down
kind: action
command: "#{address}.DB"
params:
- name: address
type: string
default: "01"
- id: channel_c_down
label: Channel C Down
kind: action
command: "#{address}.DC"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_0
label: Move to Preset 0 (Home)
kind: action
command: "#{address}.M0"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_1
label: Move to Preset 1
kind: action
command: "#{address}.M1"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_2
label: Move to Preset 2
kind: action
command: "#{address}.M2"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_3
label: Move to Preset 3
kind: action
command: "#{address}.M3"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_4
label: Move to Preset 4
kind: action
command: "#{address}.M4"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_5
label: Move to Preset 5
kind: action
command: "#{address}.M5"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_6
label: Move to Preset 6
kind: action
command: "#{address}.M6"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_7
label: Move to Preset 7
kind: action
command: "#{address}.M7"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_8
label: Move to Preset 8
kind: action
command: "#{address}.M8"
params:
- name: address
type: string
default: "01"
- id: move_to_preset_9
label: Move to Preset 9
kind: action
command: "#{address}.M9"
params:
- name: address
type: string
default: "01"
- id: preset_0_not_implemented
label: Preset 0 (Not Implemented)
kind: action
command: "#{address}.P0"
params:
- name: address
type: string
default: "01"
notes: Source lists P0 as "Not Implemented".
- id: store_preset_1
label: Store Preset 1
kind: action
command: "#{address}.P1"
params:
- name: address
type: string
default: "01"
- id: store_preset_2
label: Store Preset 2
kind: action
command: "#{address}.P2"
params:
- name: address
type: string
default: "01"
- id: store_preset_3
label: Store Preset 3
kind: action
command: "#{address}.P3"
params:
- name: address
type: string
default: "01"
- id: store_preset_4
label: Store Preset 4
kind: action
command: "#{address}.P4"
params:
- name: address
type: string
default: "01"
- id: store_preset_5
label: Store Preset 5
kind: action
command: "#{address}.P5"
params:
- name: address
type: string
default: "01"
- id: store_preset_6
label: Store Preset 6
kind: action
command: "#{address}.P6"
params:
- name: address
type: string
default: "01"
- id: store_preset_7
label: Store Preset 7
kind: action
command: "#{address}.P7"
params:
- name: address
type: string
default: "01"
- id: store_preset_8
label: Store Preset 8
kind: action
command: "#{address}.P8"
params:
- name: address
type: string
default: "01"
- id: store_preset_9
label: Store Preset 9
kind: action
command: "#{address}.P9"
params:
- name: address
type: string
default: "01"
- id: stop_motor_a
label: Stop Motor Channel A
kind: action
command: "#{address}.SA"
params:
- name: address
type: string
default: "01"
- id: stop_motor_b
label: Stop Motor Channel B
kind: action
command: "#{address}.SB"
params:
- name: address
type: string
default: "01"
- id: stop_motor_c
label: Stop Motor Channel C
kind: action
command: "#{address}.SC"
params:
- name: address
type: string
default: "01"
Feedbacks
# UNRESOLVED: source documents no query commands and no response/acknowledgement strings.
# All Actions in source are one-way fire-and-forget motor commands.
Variables
# UNRESOLVED: source does not document any settable parameters beyond per-command payload (address byte).
Events
# UNRESOLVED: source documents no unsolicited notifications.
Macros
# UNRESOLVED: source documents no multi-step sequences.
# Implicit behaviour noted: "the Door if provided (usually Channel C), it will close automatically
# when both Screen and Mask are thoroughly retracted." - this is device-internal, not user-invoked.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: source does not document explicit safety warnings, interlock procedures,
# or power-on sequencing requirements.
Notes
- Message terminator is CR (0x0D) only. Source explicitly states "definitely not a LINE FEED".
- Address byte XX: factory default 01. Syntax table lists 01/02/03/04 as unique addresses; multi-BRIC systems may have factory-assigned non-default addresses.
- Serial parameters (19200/8/N/1, no handshaking) are fixed at the device and cannot be changed via software.
- Pinout for host-side DB-9 interface cable: BRIC J6 pins — 1 RTS, 2 CTS, 3 GND, 4 TX, 5 GND, 6 RX, 7 +485, 8 -485. Source leaves DB-9 host pinout to the integrator.
- P0 is reserved and listed as "Not Implemented" by the manufacturer.
- The "M" command set moves the mask to a stored preset; the "P" command set stores the current position as a preset. M0 = home position.
Provenance
source_domains:
- convergingsystems.com
- applicationmarket.crestron.com
source_urls:
- https://www.convergingsystems.com/bin/doc/bric/bric_programmerstoolkit_V0100.pdf
- https://applicationmarket.crestron.com/content/Help/Stewart_Filmscreen/stewart_filmscreen_bric_v1_0_help.pdf
retrieved_at: 2026-06-01T23:15:20.502Z
last_checked_at: 2026-06-04T06:32:24.202Z
Verification Summary
verdict: verified
checked_at: 2026-06-04T06:32:24.202Z
matched_actions: 29
action_count: 29
confidence: medium
summary: "All 29 spec actions matched literally to Table 1 command keys; transport parameters verified against protocol specification. (10 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "firmware version not stated in source. Address range beyond 01-04 (max 04) implied by syntax table but not stated."
- "no explicit power on/off commands in source"
- "no input routing commands in source"
- "no query commands in source"
- "source documents no query commands and no response/acknowledgement strings."
- "source does not document any settable parameters beyond per-command payload (address byte)."
- "source documents no unsolicited notifications."
- "source documents no multi-step sequences."
- "source does not document explicit safety warnings, interlock procedures,"
- "feedback/response strings, query commands, event notifications, macros, and safety interlocks are not documented in the source."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0