Summary
The Sony VPL-PWZ10 Series is a projector controllable over Ethernet via the SDCP (Simple Display Control Protocol) and PJLink Class 1 protocols, as well as RS-232C serial. SDCP operates on a configurable TCP port (factory default 53484) and supports set/get commands with a community string. PJLink provides standardized power, input, mute, error, and lamp queries.
Transport
protocols:
- tcp
- serial
addressing:
port: 53484 # SDCP factory default
# UNRESOLVED: PJLink port not stated in source (PJLink standard is 4352 but not confirmed)
serial:
baud_rate: null # UNRESOLVED: baud rate not stated in source
data_bits: null # UNRESOLVED: data bits not stated in source
parity: null # UNRESOLVED: parity not stated in source
stop_bits: null # UNRESOLVED: stop bits not stated in source
flow_control: null # UNRESOLVED: flow control not stated in source
auth:
type: community # SDCP uses 4-character community string, default "SONY"; PJLink supports optional password set via web UI
notes: >-
SDCP requires matching community string (default "SONY", case-sensitive, 4 alphanumeric chars).
PJLink password can be configured from Web setting screen > Setup > Advanced Menu.
Both PJ Talk and Advertisement services are OFF by default and must be enabled.
Traits
traits:
- powerable # inferred: POWR command and power on/off via SDCP
- queryable # inferred: multiple query commands (POWR?, INPT?, AVMT?, ERST?, LAMP?, etc.)
- routable # inferred: input switching commands (INPT, SDCP input terminal set)
Actions
actions:
- id: power_on
label: Power On
kind: action
protocol: pjlink
command: "POWR 1"
params: []
- id: power_off
label: Power Off
kind: action
protocol: pjlink
command: "POWR 0"
params: []
- id: select_input
label: Select Input
kind: action
protocol: pjlink
command: "INPT <input>"
params:
- name: input
type: integer
description: "Input number (PJLink format, e.g. 21 for Video)"
- id: av_mute_set
label: Set AV Mute
kind: action
protocol: pjlink
command: "AVMT <param>"
params:
- name: param
type: integer
description: "AV mute parameter per PJLink spec"
# UNRESOLVED: exact AVMT parameter values not fully documented in source
- id: sdcp_set_input_terminal
label: Set Input Terminal (SDCP)
kind: action
protocol: sdcp
command: "SDCP SET item 00 00h-06h"
params:
- name: input_code
type: integer
description: "Input terminal code (00h=VIDEO, 01h=S VIDEO, 02h=INPUT A, 03h=INPUT B, 04h=INPUT C, 05h=USB, 06h=NETWORK)"
enum:
- value: 0
label: VIDEO
- value: 1
label: S VIDEO
- value: 2
label: INPUT A
- value: 3
label: INPUT B
- value: 4
label: INPUT C
- value: 5
label: USB (TYPE B)
- value: 6
label: NETWORK
- id: sdcp_set_aspect
label: Set Aspect Ratio (SDCP)
kind: action
protocol: sdcp
command: "SDCP SET item 0020h"
params:
- name: mode
type: integer
description: "Aspect mode value (e.g. 0003h = ZOOM)"
# UNRESOLVED: full list of aspect mode values not provided in source
- id: sdcp_set_picture_mode
label: Set Picture Mode (SDCP)
kind: action
protocol: sdcp
command: "SDCP SET item 0002h"
params:
- name: mode
type: integer
description: "Picture mode value (e.g. 0000h for dynamic)"
# UNRESOLVED: full list of picture mode values not provided in source
- id: sdcp_set_installation_location
label: Set Installation Location (SDCP)
kind: action
protocol: sdcp
command: "SDCP SET item 0x8003"
params:
- name: location
type: string
description: "Installation location string (max 24 alphanumeric characters)"
Feedbacks
feedbacks:
- id: power_state
label: Power State
type: enum
protocol: pjlink
command: "POWR?"
values:
- value: "0"
label: Standby / Power-saving
- value: "1"
label: Power ON
- value: "2"
label: Cooling
- id: input_status
label: Input Status
type: integer
protocol: pjlink
command: "INPT?"
description: "Returns current input number (PJLink format, e.g. 21 for Video)"
- id: av_mute_status
label: AV Mute Status
type: string
protocol: pjlink
command: "AVMT?"
# UNRESOLVED: response format values not fully documented in source
- id: error_status
label: Error Status
type: string
protocol: pjlink
command: "ERST?"
description: "6-digit error code. Each digit: 0=no error, 1=warning. Positions: fan, lamp, temperature, cover, filter, other"
- id: lamp_info
label: Lamp Information
type: string
protocol: pjlink
command: "LAMP?"
description: "Returns lamp count and lamp time"
- id: input_list
label: Input Switch List
type: string
protocol: pjlink
command: "INST?"
description: "Returns available input switch list"
- id: manufacturer_name
label: Manufacturer Name
type: string
protocol: pjlink
command: "INF1?"
description: "Returns manufacturer name (SONY)"
- id: model_name
label: Model Name
type: string
protocol: pjlink
command: "INF2?"
description: "Returns model name"
- id: other_info
label: Other Information
type: string
protocol: pjlink
command: "INFO?"
- id: class_info
label: Class Information
type: string
protocol: pjlink
command: "CLSS?"
description: "Returns class info (1 for Class 1)"
- id: sdcp_model_name
label: Model Name (SDCP)
type: string
protocol: sdcp
command: "SDCP GET item 0x8001"
description: "12-character alphanumeric model name"
- id: sdcp_serial_number
label: Serial Number (SDCP)
type: string
protocol: sdcp
command: "SDCP GET item 0x8002"
description: "4-byte serial number (00000000-99999999)"
- id: sdcp_installation_location
label: Installation Location (SDCP)
type: string
protocol: sdcp
command: "SDCP GET item 0x8003"
description: "24-character alphanumeric installation location"
- id: sdcp_status_error
label: Status Error (SDCP)
type: enum
protocol: sdcp
description: "Returns error status from device"
values:
- NO ERROR
- LAMP ERROR
- FAN ERROR
- COVER ERROR
- TEMP ERROR
- D5V ERROR
- POWER ERROR
- WARNING TEMP
- NVM DATA ERROR
- id: sdcp_status_power
label: Status Power (SDCP)
type: enum
protocol: sdcp
description: "Returns power status from device"
values:
- STANDBY
- START UP
Variables
# UNRESOLVED: no settable continuous parameters (volume, brightness, etc.) documented in source
Events
# SDAP advertisement broadcasts (unsolicited, when Advertisement service is enabled)
# - id: sdap_advertisement
# description: >-
# Broadcasts equipment information periodically (power, header, product name,
# location, community, serial no., status). OFF by default.
# protocol: sdap
# UNRESOLVED: SDAP broadcast format partially documented but not fully specified in source
Macros
# UNRESOLVED: no multi-step sequences described in source
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings, interlock procedures, or power-on sequencing
# requirements found in source. Never infer — only populate from explicit source text.
Notes
- SDCP packet structure: Header (VERSION=02h, CATEGORY) + Community (4 bytes) + Command (REQUEST, ITEM NO, DATA LENGTH) + Data + Checksum. Response returns ACK/NAK.
- SDCP community string default is "SONY" (case-sensitive, exactly 4 alphanumeric characters required).
- Both PJ Talk (SDCP) and Advertisement services are OFF by default and must be enabled on the projector.
- PJLink protocol is also OFF by default; enable and optionally set password via Web UI > Setup > Advanced Menu.
- SDCP version must be 2 (version field = 02h); other versions return "Invalid Version" error.
- RS-232C commands use a Simplified Command format: START CODE (A9h) + ITEM NUMBER (2 bytes) + SET/GET (00h/01h) + DATA (2 bytes) + CHECKSUM + END CODE (9Ah).
- Controller must not send multiple commands simultaneously; wait for response before sending next command.
- SDCP error codes: Item Error (01h) — Invalid Item, Invalid Item Request, Invalid Length, Invalid Data, Short Data, Not Applicable Item; Community Error — community mismatch; Request Error — Invalid Version, Invalid Equipment Category Code.
Provenance
source_domains: []
source_urls: []
retrieved_at: 2026-06-02T22:15:01.513Z
last_checked_at: 2026-06-02T22:15:01.513Z
Verification Summary
verdict: verified
checked_at: 2026-06-02T22:15:01.513Z
matched_actions: 8
action_count: 8
confidence: medium
summary: "All 8 spec actions traced to source (dip-safe re-verify). (20 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "source document title references VPL-DX/DW/EX/EW series models, not VPL-PWZ10 explicitly; protocol is assumed to be shared across Sony projector families"
- "RS-232C communication specifications (baud rate, data bits, parity, stop bits) not present in source"
- "PJLink port number not stated in source"
- "firmware version compatibility not stated"
- "PJLink port not stated in source (PJLink standard is 4352 but not confirmed)"
- "baud rate not stated in source"
- "data bits not stated in source"
- "parity not stated in source"
- "stop bits not stated in source"
- "flow control not stated in source"
- "exact AVMT parameter values not fully documented in source"
- "full list of aspect mode values not provided in source"
- "full list of picture mode values not provided in source"
- "response format values not fully documented in source"
- "no settable continuous parameters (volume, brightness, etc.) documented in source"
- "SDAP broadcast format partially documented but not fully specified in source"
- "no multi-step sequences described in source"
- "no safety warnings, interlock procedures, or power-on sequencing"
- "source document title lists VPL-DX/DW/EX/EW series, not VPL-PWZ10; assuming shared protocol across Sony projector families"
- "complete SDCP item number list not provided — only partial items documented"
- "model-specific source not located"