Summary
RS-232C serial control spec for the Sonifex S2-MT Meterbridge Timer Panel. Covers time-code synchronisation source selection, RS-232 port configuration (baud/data/stop/parity), RS-232 output string format, RS-232 input string format, date display format, and timer event configuration. Communication is via 9-pin D-type RS-232 port using ASCII text strings terminated with \r\n.
Transport
protocols:
- serial
serial:
baud_rate: 9600 # default per source option 4 sub-option 0; configurable 9600/19200/38400/57600/115200
data_bits: 8 # default per source option 1 sub-option 1; configurable 7 or 8
stop_bits: 1 # default per source option 2 sub-option 0; configurable 1 or 2
parity: none # default per source option 3 sub-option 0; configurable none/even/odd
flow_control: none # inferred: source notes only pins 2 and 3 used; no RTS/CTS flow control mentioned
auth:
type: none # inferred: no auth procedure in source
Traits
# - queryable (RS-232 output string provides status)
Actions
# Time Code Synchronisation Source (Option 0)
- id: set_time_code_source_none
label: Set Time Code Source - None
kind: action
command: "OPTION 0,0" # local configuration, no RS-232 payload documented
params: []
- id: set_time_code_source_msf
label: Set Time Code Source - MSF Radio Time Code
kind: action
command: "OPTION 0,1" # local configuration, no RS-232 payload documented
params: []
- id: set_time_code_source_dcf
label: Set Time Code Source - DCF Radio Time Code
kind: action
command: "OPTION 0,2" # local configuration, no RS-232 payload documented
params: []
- id: set_time_code_source_smpte
label: Set Time Code Source - SMPTE/EBU Time Code
kind: action
command: "OPTION 0,3" # local configuration, no RS-232 payload documented
params: []
- id: set_time_code_source_rs232
label: Set Time Code Source - RS232 Time Code String
kind: action
command: "OPTION 0,4" # local configuration, no RS-232 payload documented
params: []
# RS-232 Data Bits (Option 1)
- id: set_rs232_data_bits_7
label: Set RS-232 Data Bits - 7
kind: action
command: "OPTION 1,0"
params: []
- id: set_rs232_data_bits_8
label: Set RS-232 Data Bits - 8
kind: action
command: "OPTION 1,1"
params: []
# RS-232 Stop Bits (Option 2)
- id: set_rs232_stop_bits_1
label: Set RS-232 Stop Bits - 1
kind: action
command: "OPTION 2,0"
params: []
- id: set_rs232_stop_bits_2
label: Set RS-232 Stop Bits - 2
kind: action
command: "OPTION 2,1"
params: []
# RS-232 Parity (Option 3)
- id: set_rs232_parity_none
label: Set RS-232 Parity - None
kind: action
command: "OPTION 3,0"
params: []
- id: set_rs232_parity_even
label: Set RS-232 Parity - Even
kind: action
command: "OPTION 3,1"
params: []
- id: set_rs232_parity_odd
label: Set RS-232 Parity - Odd
kind: action
command: "OPTION 3,2"
params: []
# RS-232 Baud Rate (Option 4)
- id: set_rs232_baud_9600
label: Set RS-232 Baud Rate - 9600
kind: action
command: "OPTION 4,0"
params: []
- id: set_rs232_baud_19200
label: Set RS-232 Baud Rate - 19200
kind: action
command: "OPTION 4,1"
params: []
- id: set_rs232_baud_38400
label: Set RS-232 Baud Rate - 38400
kind: action
command: "OPTION 4,2"
params: []
- id: set_rs232_baud_57600
label: Set RS-232 Baud Rate - 57600
kind: action
command: "OPTION 4,3"
params: []
- id: set_rs232_baud_115200
label: Set RS-232 Baud Rate - 115200
kind: action
command: "OPTION 4,4"
params: []
# RS-232 Output Enable (Option 5)
- id: set_rs232_output_disable
label: Set RS-232 Output - Disable
kind: action
command: "OPTION 5,0"
params: []
- id: set_rs232_output_enable
label: Set RS-232 Output - Enable
kind: action
command: "OPTION 5,1"
params: []
# Date Display Format (Option 6)
- id: set_date_format_dd_mm_yy
label: Set Date Display Format - dd/mm/yy
kind: action
command: "OPTION 6,0"
params: []
- id: set_date_format_dd_yy_mm
label: Set Date Display Format - dd/yy/mm
kind: action
command: "OPTION 6,1"
params: []
- id: set_date_format_mm_dd_yy
label: Set Date Display Format - mm/dd/yy
kind: action
command: "OPTION 6,2"
params: []
- id: set_date_format_mm_yy_dd
label: Set Date Display Format - mm/yy/dd
kind: action
command: "OPTION 6,3"
params: []
- id: set_date_format_yy_dd_mm
label: Set Date Display Format - yy/dd/mm
kind: action
command: "OPTION 6,4"
params: []
- id: set_date_format_yy_mm_dd
label: Set Date Display Format - yy/mm/dd
kind: action
command: "OPTION 6,5"
params: []
# Timer 1 Display Behaviour (Option 7)
- id: set_timer1_no_display
label: Set Timer 1 - On event do not display
kind: action
command: "OPTION 7,0"
params: []
- id: set_timer1_display1
label: Set Timer 1 - On event show to display 1
kind: action
command: "OPTION 7,1"
params: []
- id: set_timer1_display2
label: Set Timer 1 - On event show to display 2
kind: action
command: "OPTION 7,2"
params: []
# Timer 1 Event Option (Option 8)
- id: set_timer1_event_restart
label: Set Timer 1 Event - Restart
kind: action
command: "OPTION 8,0"
params: []
- id: set_timer1_event_split
label: Set Timer 1 Event - Split
kind: action
command: "OPTION 8,1"
params: []
# Timer 2 Display Behaviour (Option 9)
- id: set_timer2_no_display
label: Set Timer 2 - On event do not display
kind: action
command: "OPTION 9,0"
params: []
- id: set_timer2_display1
label: Set Timer 2 - On event show to display 1
kind: action
command: "OPTION 9,1"
params: []
- id: set_timer2_display2
label: Set Timer 2 - On event show to display 2
kind: action
command: "OPTION 9,2"
params: []
# Timer 2 Event Option (Option 10)
- id: set_timer2_event_restart
label: Set Timer 2 Event - Restart
kind: action
command: "OPTION 10,0"
params: []
- id: set_timer2_event_split
label: Set Timer 2 Event - Split
kind: action
command: "OPTION 10,1"
params: []
# Mic Timer Display Behaviour (Option 11)
- id: set_mic_timer_no_display
label: Set Mic Timer - On event do not display
kind: action
command: "OPTION 11,0"
params: []
- id: set_mic_timer_display1
label: Set Mic Timer - On event show to display 1
kind: action
command: "OPTION 11,1"
params: []
- id: set_mic_timer_display2
label: Set Mic Timer - On event show to display 2
kind: action
command: "OPTION 11,2"
params: []
# Mic Timer Control (Option 12)
- id: set_mic_timer_auto
label: Set Mic Timer Control - Auto
kind: action
command: "OPTION 12,0"
params: []
- id: set_mic_timer_manual
label: Set Mic Timer Control - Manual
kind: action
command: "OPTION 12,1"
params: []
# Freeze Time (Option 13)
- id: set_freeze_time_1s
label: Set Freeze Time - 1 second
kind: action
command: "OPTION 13,0"
params: []
- id: set_freeze_time_2s
label: Set Freeze Time - 2 seconds
kind: action
command: "OPTION 13,1"
params: []
- id: set_freeze_time_3s
label: Set Freeze Time - 3 seconds
kind: action
command: "OPTION 13,2"
params: []
- id: set_freeze_time_4s
label: Set Freeze Time - 4 seconds
kind: action
command: "OPTION 13,3"
params: []
- id: set_freeze_time_5s
label: Set Freeze Time - 5 seconds
kind: action
command: "OPTION 13,4"
params: []
# Time Setting (Option 14)
- id: set_time_disallow_locked
label: Set Time Setting - Disallow while locked
kind: action
command: "OPTION 14,0"
params: []
- id: set_time_allow_locked
label: Set Time Setting - Allow while locked
kind: action
command: "OPTION 14,1"
params: []
# SMPTE/EBU Timecode Settings (Option 15)
- id: set_smpte_ignore_date
label: Set SMPTE/EBU - Ignore date
kind: action
command: "OPTION 15,0"
params: []
- id: set_smpte_date_format_1
label: Set SMPTE/EBU - Date Format 1
kind: action
command: "OPTION 15,1"
params: []
- id: set_smpte_date_format_2
label: Set SMPTE/EBU - Date Format 2
kind: action
command: "OPTION 15,2"
params: []
- id: set_smpte_date_format_3
label: Set SMPTE/EBU - Date Format 3
kind: action
command: "OPTION 15,3"
params: []
# RS-232 I/O
- id: send_time_code_input
label: Send Time Code Input String
kind: action
command: "\"dd/mm/yy,hh:mm:ss\\r\\n\""
params:
- name: date
type: string
description: Date string in configured display format
- name: time
type: string
description: Time string hh:mm:ss
- id: query_status_output
label: Receive RS-232 Status Output
kind: query
command: "\"dd/mm/yy,hh:mm:ss,A,B,C,D,hh:mm:ss.tt,hh:mm:ss.tt,hh:mm:ss.tt\\r\\n\""
params: []
Feedbacks
- id: rs232_output_string
type: string
description: >-
Output emitted when RS-232 output enabled. Format:
"dd/mm/yy,hh:mm:ss,A,B,C,D,hh:mm:ss.tt,hh:mm:ss.tt,hh:mm:ss.tt\r\n"
where A=date format, B=time code source, C=lock status (0=not locked,
1=signal/not locked, 2=locked), D=timecode presence (0=no signal,
1=signal present), then Timer1, Timer2, MicTimer.
- id: lock_status
type: enum
values: [not_locked, signal_not_locked, locked]
- id: time_code_source
type: enum
values: [none, msf, dcf, smpte_ebu, rs232]
Variables
# UNRESOLVED: source documents configuration as menu options (local button press),
# not as RS-232 commands. No variable parameters exposed over the serial link
# beyond the date/time string input.
Events
# UNRESOLVED: source describes event-triggered timer behaviour but does not
# document unsolicited RS-232 event notifications.
Macros
# UNRESOLVED: source does not document multi-step RS-232 sequences.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: source contains no safety warnings, interlock procedures, or
# power-on sequencing requirements.
Notes
User supplied device name "Sonifex S2 Cds" but source document describes the S2-MT Meterbridge Timer Panel. Spec authored against the S2-MT source.
Source documents configuration options (options 0-15) accessed via local front-panel button sequence (hold lower-timer Mode button 5s, increment options, set sub-option with Start/Stop & Reset, final press stores). RS-232 port is used for time-code string I/O and status output, not for menu configuration; no RS-232 commands for setting options 0-15 are documented.
RS-232 input: ASCII string "dd/mm/yy,hh:mm:ss\r\n" (date format depends on option 6 setting).
RS-232 output: ASCII string "dd/mm/yy,hh:mm:ss,A,B,C,D,hh:mm:ss.tt,hh:mm:ss.tt,hh:mm:ss.tt\r\n" emitted periodically when output enabled (option 5 sub-option 1).
Only pins 2 (RX) and 3 (TX) of the 9-pin D-type connector are used per source.
Action command fields for options 0-15 are placeholders showing the conceptual operation, not literal RS-232 byte sequences. Source does not document an RS-232 command protocol for these configuration actions.
Spec drafted. Caveat: source doc = S2-MT Meterbridge Timer Panel, not "S2 Cds" as supplied. Flagged in Notes.
## Provenance
```yaml
source_domains:
- ad56550c.delivery.rocketcdn.me
- cdn.abicart.com
source_urls:
- https://ad56550c.delivery.rocketcdn.me/wp-content/uploads/products/S2-CDS/s2_hb.pdf
- https://cdn.abicart.com/shop/ws42/76342/art41/159887241-5fe61b-sonifex_s2_manual.pdf
retrieved_at: 2026-07-22T05:08:55.986Z
last_checked_at: 2026-07-22T07:46:35.075Z
Verification Summary
verdict: verified
checked_at: 2026-07-22T07:46:35.075Z
matched_actions: 53
action_count: 53
confidence: medium
summary: "All 53 actions verified against source options and I/O formats; transport parameters confirmed. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "user supplied device name \"S2 Cds\" but source document describes the S2-MT Meterbridge Timer Panel. Spec authored against S2-MT source."
- "no safety warnings, interlocks, or power-on sequencing requirements present in source."
- "source documents configuration as menu options (local button press),"
- "source describes event-triggered timer behaviour but does not"
- "source does not document multi-step RS-232 sequences."
- "source contains no safety warnings, interlock procedures, or"
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0