Summary
8×8 matrix switcher supporting RS-232C serial control. Controls input/output routing (6 inputs → 4 outputs), power, front panel lock, and device reset. Serial config: 9600 bps, 8N1, no flow control.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: UNRESOLVED # source does not state this (was inferred none: no auth procedure in source)
Traits
- powerable
- routable
- queryable
Actions
- id: power_on
label: Power On
kind: action
params: []
- id: power_off
label: Power Off
kind: action
params: []
- id: set_channel_1
label: Set Channel 1 Source
kind: action
params:
- name: input
type: integer
description: Source input number (01-06)
- id: set_channel_2
label: Set Channel 2 Source
kind: action
params:
- name: input
type: integer
description: Source input number (01-06)
- id: set_channel_3
label: Set Channel 3 Source
kind: action
params:
- name: input
type: integer
description: Source input number (01-06)
- id: set_channel_4
label: Set Channel 4 Source
kind: action
params:
- name: input
type: integer
description: Source input number (01-06)
- id: lock_on
label: Lock Front Panel On
kind: action
params: []
- id: lock_off
label: Lock Front Panel Off
kind: action
params: []
- id: reset
label: Reset Device
kind: action
params: []
- id: ask_status
label: Ask Status
kind: action
params: []
Feedbacks
- id: power_on_ack
label: Power On Acknowledge
type: string
values:
- SBaLonaK
query_command: SBSYSmon
- id: power_off_ack
label: Power Off Acknowledge
type: string
values:
- SBaLoFaK
query_command: SBSYSmoF
- id: channel_1_updated
label: Channel 1 Updated
type: string
values:
- SBUdxxo1 # xx = source input 01-06
query_command: SBIxxo01
- id: channel_2_updated
label: Channel 2 Updated
type: string
values:
- SBUdxxo2 # xx = source input 01-06
query_command: SBIxxo02
- id: channel_3_updated
label: Channel 3 Updated
type: string
values:
- SBUdxxo4 # xx = source input 01-06
query_command: SBIxxo03
- id: channel_4_updated
label: Channel 4 Updated
type: string
values:
- SBUdxxo3 # xx = source input 01-06
query_command: SBIxxo04
- id: lock_on_ack
label: Lock On Acknowledge
type: string
values:
- SBSYSLoK
query_command: SBSYSmLK
- id: lock_off_ack
label: Lock Off Acknowledge
type: string
values:
- SBSYSULK
query_command: SBSYSmUK
- id: reset_ack
label: Reset Acknowledge
type: string
values:
- SBRStaCK
query_command: SBaLLRSt
- id: status_ack
label: Status Acknowledge
type: string
values:
- SBStataK
query_command: SBaSKSta
- id: inout_state
label: IN/OUT State
type: string
values:
- SBUD0000XXYY # XX = input port 01-06, YY = output port 01-06
query_command: SBaSKSta
note: Sent sequentially after SBASKSTA request. All 10 feedback commands sent in sequence after status request.
Variables
# UNRESOLVED: no discrete queryable parameters other than status request
Events
# UNRESOLVED: no unsolicited event documentation
Macros
# UNRESOLVED: no explicit multi-step sequences documented
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings or interlock procedures in source
Notes
On power-on reset, all destinations set to Source 1. When front panel is locked, all status changes are made via RS-232 only. The device sends all 10 feedback commands sequentially after receiving the status request.
Provenance
source_domains:
- shinybowusa.com
- startelektronik.com.tr
source_urls:
- https://shinybowusa.com/PDF/RS232_V1.0.pdf
- https://www.startelektronik.com.tr/pdf/shinybow/SB5608/SB5608_Kullanim_Klavuzu.pdf
retrieved_at: 2026-05-21T22:03:44.223Z
last_checked_at: 2026-10-07T13:27:18.352Z
Verification Summary
verdict: verified
checked_at: 2026-10-07T13:27:18.352Z
matched_actions: 21
action_count: 21
confidence: medium
summary: "All 21 units match source commands (10 controller commands, 10 feedback replies, IN/OUT state); serial settings verbatim; source generic 'all devices except SB-5688'. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "full command syntax (byte-level structure) not detailed beyond ASCII mnemonics. UNRESOLVED: device applies to all models except SB-5688."
- "no discrete queryable parameters other than status request"
- "no unsolicited event documentation"
- "no explicit multi-step sequences documented"
- "no safety warnings or interlock procedures in source"
- "byte-level command packet structure not detailed — only ASCII mnemonics provided. UNRESOLVED: whether device auto-reports state changes (unsolicited) not confirmed."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0