Summary
Shinybow SB-5582 is a 6x4 component matrix switcher controlled over RS-232. This spec covers the RS-232 protocol version 1.0 documented in the vendor manual (Encl00RS23200a0, FEB 2016), which applies to all Shinybow devices except SB-5688. The protocol uses 8-byte ASCII commands at 9600 bps for power, input/output routing, front-panel lock, reset, and status query.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: UNRESOLVED # source does not state this (was inferred none: no auth procedure in source)
Traits
- powerable # inferred from SBSYSMON / SBSYSMOF power commands
- routable # inferred from SBIxxOyy channel routing commands
- queryable # inferred from SBASKSTA status query
Actions
- id: power_on
label: Power On
kind: action
command: "SBSYSMON"
params: []
- id: power_off
label: Power Off
kind: action
command: "SBSYSMOF"
params: []
- id: route_input_to_output_1
label: Channel 1 Setting (route input to output 1)
kind: action
command: "SBI{xx}O01"
params:
- name: xx
type: string
description: Input number, zero-padded two-digit ASCII, 01-06
enum: ["01", "02", "03", "04", "05", "06"]
- id: route_input_to_output_2
label: Channel 2 Setting (route input to output 2)
kind: action
command: "SBI{xx}O02"
params:
- name: xx
type: string
description: Input number, zero-padded two-digit ASCII, 01-06
enum: ["01", "02", "03", "04", "05", "06"]
- id: route_input_to_output_3
label: Channel 3 Setting (route input to output 3)
kind: action
command: "SBI{xx}O03"
params:
- name: xx
type: string
description: Input number, zero-padded two-digit ASCII, 01-06
enum: ["01", "02", "03", "04", "05", "06"]
- id: route_input_to_output_4
label: Channel 4 Setting (route input to output 4)
kind: action
command: "SBI{xx}O04"
params:
- name: xx
type: string
description: Input number, zero-padded two-digit ASCII, 01-06
enum: ["01", "02", "03", "04", "05", "06"]
- id: front_panel_lock_on
label: Front Panel Lock Toggle On
kind: action
command: "SBSYSMLK"
params: []
notes: When locked on, all status changes only via RS-232.
- id: front_panel_lock_off
label: Front Panel Lock Toggle Off
kind: action
command: "SBSYSMUK"
params: []
- id: reset_all
label: Reset
kind: action
command: "SBALLRST"
params: []
notes: Resets device; all destinations set to Source 1.
- id: ask_status
label: Ask Status
kind: query
command: "SBASKSTA"
params: []
notes: |
Triggers a multi-frame feedback sequence: device replies with reset-ack,
power state (1st/2nd), then IN/OUT state for each channel, then lock
state (7th/8th), in that order.
Feedbacks
- id: power_on_ack
label: Power On Acknowledge
command: "SBALONAK"
type: enum
values: [received]
description: Acknowledges system power-on command.
- id: power_off_ack
label: Power Off Acknowledge
command: "SBALOFAK"
type: enum
values: [received]
description: Acknowledges system power-off command.
- id: channel_1_updated
label: Channel 1 Updated
command: "SBUD{xx}O1"
type: string
description: 1st output signal changed; xx = selected source (01-06).
- id: channel_2_updated
label: Channel 2 Updated
command: "SBUD{xx}O2"
type: string
description: 2nd output signal changed; xx = selected source (01-06).
- id: channel_3_updated
label: Channel 3 Updated
command: "SBUD{xx}O4" # verbatim from source: row 5 of feedback table uses O4 for "Channel 3 Updated"
type: string
description: |
3rd output signal changed; xx = selected source (01-06).
NOTE: source table lists this token as "SBUDxxO4" under "Channel 3 Updated"
and "SBUDxxO3" under "Channel 4 Updated" - preserved verbatim from source.
This is a likely vendor documentation swap; behaviour on real hardware
not verified.
- id: channel_4_updated
label: Channel 4 Updated
command: "SBUD{xx}O3" # verbatim from source: row 6 of feedback table uses O3 for "Channel 4 Updated"
type: string
description: |
4th output signal changed; xx = selected source (01-06).
See note on channel_3_updated regarding source table ordering.
- id: lock_on
label: Lock On
command: "SBSYSLOK"
type: enum
values: [locked]
description: Reports front panel is locked.
- id: lock_off
label: Lock Off
command: "SBSYSULK"
type: enum
values: [unlocked]
description: Reports front panel lock released.
- id: reset_ack
label: Reset Acknowledge
command: "SBRSTACK"
type: enum
values: [received]
description: Acknowledges reset command.
- id: status_ack
label: Status Acknowledge
command: "SBSTATAK"
type: enum
values: [received]
description: Acknowledges ask-status command (first frame of multi-frame status reply).
- id: in_out_state
label: IN/OUT State
command: "SBUD0000{xx}{yy}"
type: string
description: |
Per-channel input/output mapping reported as part of the ask-status
response sequence. xx = input port (01-06), yy = output port (01-06).
Variables
# UNRESOLVED: no separately settable parameters beyond the routing/power/lock
# actions above are documented in the refined source.
Events
# UNRESOLVED: source documents feedback frames sent in response to commands;
# no unsolicited (non-request-driven) event notifications are described.
Macros
# UNRESOLVED: no multi-step macro sequences described in source.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings, interlock procedures, or power-on sequencing
# requirements present in the refined RS-232 protocol excerpt.
Notes
- Wire-level framing: every command is exactly 8 ASCII bytes; the first six bytes carry the action token and the remaining two bytes carry the action parameter (e.g.
O01..O04channel selector,xxinput selector). - The protocol header states it "applies to all devices except SB-5688", confirming SB-5582 is covered.
- The
SBASKSTAquery returns a multi-frame reply: reset-ack, power state, per-channel IN/OUT mapping (SBUD0000xxyy), then lock state — emitted sequentially by the device. - Feedback tokens
SBUDxxO4(labelled "Channel 3 Updated") andSBUDxxO3(labelled "Channel 4 Updated") appear swapped in the vendor table; preserved verbatim because the spec must not silently correct documented payloads. Validate on real hardware before relying on either channel-3 or channel-4 feedback parsing. - Source document part number:
Encl00RS23200a0, dated FEB 2016, RS-232 protocol version 1.0.
Provenance
source_domains:
- shinybowusa.com
source_urls:
- https://shinybowusa.com/PDF/RS232_V1.0.pdf
retrieved_at: 2026-06-02T19:51:08.682Z
last_checked_at: 2026-10-01T10:58:40.794Z
Verification Summary
verdict: verified
checked_at: 2026-10-01T10:58:40.794Z
matched_actions: 10
action_count: 10
confidence: medium
summary: "All 10 spec action units map to the 10 source controlling commands; transport (9600, 8N1, no flow) matches; coverage 10/10. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "physical serial connector pinout not in refined excerpt; firmware version compatibility not stated."
- "no separately settable parameters beyond the routing/power/lock"
- "source documents feedback frames sent in response to commands;"
- "no multi-step macro sequences described in source."
- "no safety warnings, interlock procedures, or power-on sequencing"
- "firmware version compatibility range; physical DB9 pinout; command inter-character / inter-command timing; behaviour when an unknown command is received."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0