Summary
Matrix switcher with 6 inputs and 4 outputs. RS-232C serial control at 9600 bps 8-N-1. Supports per-output input selection, front panel lock, power on/off, and device reset.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Traits
powerable: true # power on/off commands present
routable: true # per-output input routing commands present
queryable: true # status query command present
Actions
- id: power_on
label: Power On
kind: action
params: []
- id: power_off
label: Power Off
kind: action
params: []
- id: set_channel_1
label: Set Channel 1 Input
kind: action
params:
- name: input
type: integer
description: Source input number (1-6)
range: [1, 6]
- id: set_channel_2
label: Set Channel 2 Input
kind: action
params:
- name: input
type: integer
description: Source input number (1-6)
range: [1, 6]
- id: set_channel_3
label: Set Channel 3 Input
kind: action
params:
- name: input
type: integer
description: Source input number (1-6)
range: [1, 6]
- id: set_channel_4
label: Set Channel 4 Input
kind: action
params:
- name: input
type: integer
description: Source input number (1-6)
range: [1, 6]
- id: lock_on
label: Lock Front Panel On
kind: action
params: []
- id: lock_off
label: Lock Front Panel Off
kind: action
params: []
- id: reset
label: Reset Device
kind: action
params: []
- id: ask_status
label: Ask Status
kind: action
params: []
Feedbacks
- id: power_on_ack
label: Power On Acknowledge
response: SBaLonaK
- id: power_off_ack
label: Power Off Acknowledge
response: SBaLoFaK
- id: channel_1_updated
label: Channel 1 Updated
response: SBUdxxo1
params:
- name: input
type: integer
description: Selected source (1-6)
- id: channel_2_updated
label: Channel 2 Updated
response: SBUdxxo2
params:
- name: input
type: integer
description: Selected source (1-6)
- id: channel_3_updated
label: Channel 3 Updated
response: SBUdxxo4
params:
- name: input
type: integer
description: Selected source (1-6)
- id: channel_4_updated
label: Channel 4 Updated
response: SBUdxxo3
params:
- name: input
type: integer
description: Selected source (1-6)
- id: lock_on_status
label: Lock On Status
response: SBSYSLoK
- id: lock_off_status
label: Lock Off Status
response: SBSYSULK
- id: reset_ack
label: Reset Acknowledge
response: SBRStaCK
- id: status_ack
label: Status Acknowledge
response: SBStataK
Variables
# UNRESOLVED: no standalone settable parameters documented
Events
# UNRESOLVED: no unsolicited event notifications documented
Macros
# UNRESOLVED: no multi-step macros documented
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings or interlock procedures in source
Notes
After receiving SBASKSTA, device sends 10 sequential feedback responses: power ack, lock status, reset ack, status ack, then IN/OUT state commands (SBUD0000XXYY where XX=input 01–06, YY=output 01–04).
Provenance
source_domains:
- shinybowusa.com
- manualslib.com
source_urls:
- https://www.shinybowusa.com/PDF/RS232_V1.0.pdf
- "https://www.manualslib.com/manual/1854379/Shinybow-Usa-8x2-Multivideo-To-Vga-Switcher-Series.html?page=8"
retrieved_at: 2026-05-21T21:31:27.380Z
last_checked_at: 2026-05-31T21:21:14.612Z
Verification Summary
verdict: verified
checked_at: 2026-05-31T21:21:14.612Z
matched_actions: 10
action_count: 10
confidence: medium
summary: "All 10 spec actions matched distinct source control commands; transport params verified; complete bidirectional coverage. (7 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "no standalone settable parameters documented"
- "no unsolicited event notifications documented"
- "no multi-step macros documented"
- "no safety warnings or interlock procedures in source"
- "firmware version compatibility not stated in source"
- "RS-232 connector pinout not stated in source"
- "command timing or inter-command delay requirements not stated in source"