Summary
Sharp/NEC projector control spec covering RS-232C serial and TCP/IP (wired/wireless LAN) control. Uses a binary framed command protocol with checksummed hex payloads (BDT140013 Rev 7.1). Covers power, input switching, mute, picture/volume/lens adjustment, status queries, and lens memory control.
Transport
protocols:
- tcp
- serial
addressing:
port: 7142
serial:
baud_rate: null # UNRESOLVED: default baud not stated; source lists supported set 115200/38400/19200/9600/4800 bps
data_bits: 8
parity: none
stop_bits: 1
flow_control: none # UNRESOLVED: flow control not stated (RTS/CTS pins present on connector)
auth:
type: none # inferred: no auth procedure in source
Traits
traits:
- powerable # inferred: POWER ON / POWER OFF commands present
- routable # inferred: INPUT SW CHANGE command present
- queryable # inferred: many status/information request commands present
- levelable # inferred: PICTURE ADJUST / VOLUME ADJUST commands present
Actions
# Protocol framing: each command is a hex byte sequence. Framing bytes
# (first byte = message-type/op marker), ID1 (control ID), ID2 (model code),
# and CKS (checksum = low byte of sum of all preceding bytes) are part of the
# wire format. ID1/ID2 are runtime-substituted; CKS is computed. Payloads below
# are copied verbatim from the source.
# Model code ID2: UNRESOLVED (varies by model; not stated for Me651).
- id: error_status_request
label: Error Status Request (009)
kind: query
command: "00h 88h 00h 00h 00h 88h"
params: []
- id: power_on
label: Power On (015)
kind: action
command: "02h 00h 00h 00h 00h 02h"
params: []
- id: power_off
label: Power Off (016)
kind: action
command: "02h 01h 00h 00h 00h 03h"
params: []
- id: input_sw_change
label: Input SW Change (018)
kind: action
command: "02h 03h 00h 00h 02h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Input terminal value (e.g. 06h = video port); see Appendix "Supplementary Information by Command". Exact values UNRESOLVED - referenced but not listed in this excerpt.
- id: picture_mute_on
label: Picture Mute On (020)
kind: action
command: "02h 10h 00h 00h 00h 12h"
params: []
- id: picture_mute_off
label: Picture Mute Off (021)
kind: action
command: "02h 11h 00h 00h 00h 13h"
params: []
- id: sound_mute_on
label: Sound Mute On (022)
kind: action
command: "02h 12h 00h 00h 00h 14h"
params: []
- id: sound_mute_off
label: Sound Mute Off (023)
kind: action
command: "02h 13h 00h 00h 00h 15h"
params: []
- id: onscreen_mute_on
label: Onscreen Mute On (024)
kind: action
command: "02h 14h 00h 00h 00h 16h"
params: []
- id: onscreen_mute_off
label: Onscreen Mute Off (025)
kind: action
command: "02h 15h 00h 00h 00h 17h"
params: []
- id: picture_adjust
label: Picture Adjust (030-1)
kind: action
command: "03h 10h 00h 00h 05h <DATA01> FFh <DATA02> <DATA03> <DATA04> <CKS>"
params:
- name: DATA01
type: integer
description: "Adjustment target: 00h=Brightness, 01h=Contrast, 02h=Color, 03h=Hue, 04h=Sharpness"
- name: DATA02
type: integer
description: "Adjustment mode: 00h=absolute, 01h=relative"
- name: DATA03
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA04
type: integer
description: Adjustment value (high-order 8 bits)
- id: volume_adjust
label: Volume Adjust (030-2)
kind: action
command: "03h 10h 00h 00h 05h 05h 00h <DATA01> <DATA02> <DATA03> <CKS>"
params:
- name: DATA01
type: integer
description: "Adjustment mode: 00h=absolute, 01h=relative"
- name: DATA02
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA03
type: integer
description: Adjustment value (high-order 8 bits)
- id: aspect_adjust
label: Aspect Adjust (030-12)
kind: action
command: "03h 10h 00h 00h 05h 18h 00h 00h <DATA01> 00h <CKS>"
params:
- name: DATA01
type: integer
description: Value set for the aspect; see Appendix "Supplementary Information by Command". Exact values UNRESOLVED - referenced but not listed in this excerpt.
- id: other_adjust
label: Other Adjust (030-15)
kind: action
command: "03h 10h 00h 00h 05h <DATA01> <DATA02> <DATA03> <DATA04> <DATA05> <CKS>"
params:
- name: DATA01
type: integer
description: "Adjustment target high byte (96h = LAMP ADJUST / LIGHT ADJUST when DATA02=FFh)"
- name: DATA02
type: integer
description: "Adjustment target low byte (FFh for LAMP/LIGHT ADJUST)"
- name: DATA03
type: integer
description: "Adjustment mode: 00h=absolute, 01h=relative"
- name: DATA04
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA05
type: integer
description: Adjustment value (high-order 8 bits)
- id: information_request
label: Information Request (037)
kind: query
command: "03h 8Ah 00h 00h 00h 8Dh"
params: []
- id: filter_usage_information_request
label: Filter Usage Information Request (037-3)
kind: query
command: "03h 95h 00h 00h 00h 98h"
params: []
- id: lamp_information_request_3
label: Lamp Information Request 3 (037-4)
kind: query
command: "03h 96h 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: "Lamp selector: 00h=Lamp 1, 01h=Lamp 2 (two-lamp models only)"
- name: DATA02
type: integer
description: "Content: 01h=lamp usage time (seconds), 04h=lamp remaining life (%)"
- id: carbon_savings_information_request
label: Carbon Savings Information Request (037-6)
kind: query
command: "03h 9Ah 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "00h=Total Carbon Savings, 01h=Carbon Savings during operation"
- id: remote_key_code
label: Remote Key Code (050)
kind: action
command: "02h 0Fh 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: "Key code low byte (WORD type). Source key codes include: 02h=POWER ON, 03h=POWER OFF, 05h=AUTO, 06h=MENU, 07h=UP, 08h=DOWN, 09h=RIGHT, 0Ah=LEFT, 0Bh=ENTER, 0Ch=EXIT, 0Dh=HELP, 0Fh=MAGNIFY UP, 10h=MAGNIFY DOWN, 13h=MUTE, 29h=PICTURE, 4Bh=COMPUTER1, 4Ch=COMPUTER2, 4Fh=VIDEO1, 51h=S-VIDEO1, 84h=VOLUME UP, 85h=VOLUME DOWN, 8Ah=FREEZE, A3h=ASPECT, D7h=SOURCE, EEh=LAMP MODE/ECO"
- name: DATA02
type: integer
description: Key code high byte (00h for all listed codes)
- id: shutter_close
label: Shutter Close (051)
kind: action
command: "02h 16h 00h 00h 00h 18h"
params: []
- id: shutter_open
label: Shutter Open (052)
kind: action
command: "02h 17h 00h 00h 00h 19h"
params: []
- id: lens_control
label: Lens Control (053)
kind: action
command: "02h 18h 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: "Lens axis: 06h=Periphery Focus (other axis values referenced via Appendix)"
- name: DATA02
type: integer
description: "Content: 00h=Stop, 01h=drive +1s, 02h=drive +0.5s, 03h=drive +0.25s, 7Fh=drive plus (continuous), 81h=drive minus (continuous), FDh=drive -0.25s, FEh=drive -0.5s, FFh=drive -1s"
- id: lens_control_request
label: Lens Control Request (053-1)
kind: query
command: "02h 1Ch 00h 00h 02h <DATA01> 00h <CKS>"
params:
- name: DATA01
type: integer
description: Lens axis selector (same values as 053 DATA01)
- id: lens_control_2
label: Lens Control 2 (053-2)
kind: action
command: "02h 1Dh 00h 00h 04h <DATA01> <DATA02> <DATA03> <DATA04> <CKS>"
params:
- name: DATA01
type: integer
description: "Lens axis (FFh = Stop; if Stop, DATA02-04 not referenced)"
- name: DATA02
type: integer
description: "Adjustment mode: 00h=absolute, 02h=relative"
- name: DATA03
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA04
type: integer
description: Adjustment value (high-order 8 bits)
- id: lens_memory_control
label: Lens Memory Control (053-3)
kind: action
command: "02h 1Eh 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "Operation: 00h=MOVE, 01h=STORE, 02h=RESET"
- id: reference_lens_memory_control
label: Reference Lens Memory Control (053-4)
kind: action
command: "02h 1Fh 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "Operation: 00h=MOVE, 01h=STORE, 02h=RESET (applies to profile set via 053-10)"
- id: lens_memory_option_request
label: Lens Memory Option Request (053-5)
kind: query
command: "02h 20h 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "Option: 00h=LOAD BY SIGNAL, 01h=FORCED MUTE"
- id: lens_memory_option_set
label: Lens Memory Option Set (053-6)
kind: action
command: "02h 21h 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: "Option: 00h=LOAD BY SIGNAL, 01h=FORCED MUTE"
- name: DATA02
type: integer
description: "Setting value: 00h=OFF, 01h=ON"
- id: lens_information_request
label: Lens Information Request (053-7)
kind: query
command: "02h 22h 00h 00h 01h 00h 25h"
params: []
- id: lens_profile_set
label: Lens Profile Set (053-10)
kind: action
command: "02h 27h 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "Profile number: 00h=Profile 1, 01h=Profile 2"
- id: lens_profile_request
label: Lens Profile Request (053-11)
kind: query
command: "02h 28h 00h 00h 00h 2Ah"
params: []
- id: gain_parameter_request_3
label: Gain Parameter Request 3 (060-1)
kind: query
command: "03h 05h 00h 00h 03h <DATA01> 00h 00h <CKS>"
params:
- name: DATA01
type: integer
description: "Adjusted value name: 00h=BRIGHTNESS, 01h=CONTRAST, 02h=COLOR, 03h=HUE, 04h=SHARPNESS, 05h=VOLUME, 96h=LAMP/LIGHT ADJUST"
- id: setting_request
label: Setting Request (078-1)
kind: query
command: "00h 85h 00h 00h 01h 00h 86h"
params: []
- id: running_status_request
label: Running Status Request (078-2)
kind: query
command: "00h 85h 00h 00h 01h 01h 87h"
params: []
- id: input_status_request
label: Input Status Request (078-3)
kind: query
command: "00h 85h 00h 00h 01h 02h 88h"
params: []
- id: mute_status_request
label: Mute Status Request (078-4)
kind: query
command: "00h 85h 00h 00h 01h 03h 89h"
params: []
- id: model_name_request
label: Model Name Request (078-5)
kind: query
command: "00h 85h 00h 00h 01h 04h 8Ah"
params: []
- id: cover_status_request
label: Cover Status Request (078-6)
kind: query
command: "00h 85h 00h 00h 01h 05h 8Bh"
params: []
- id: freeze_control
label: Freeze Control (079)
kind: action
command: "01h 98h 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "01h=freeze on, 02h=freeze off"
- id: information_string_request
label: Information String Request (084)
kind: query
command: "00h D0h 00h 00h 03h 00h <DATA01> 01h <CKS>"
params:
- name: DATA01
type: integer
description: "Information type: 03h=Horizontal synchronous frequency, 04h=Vertical synchronous frequency"
- id: eco_mode_request
label: Eco Mode Request (097-8)
kind: query
command: "03h B0h 00h 00h 01h 07h BBh"
params: []
- id: lan_projector_name_request
label: LAN Projector Name Request (097-45)
kind: query
command: "03h B0h 00h 00h 01h 2Ch E0h"
params: []
- id: lan_mac_address_status_request_2
label: LAN MAC Address Status Request 2 (097-155)
kind: query
command: "03h B0h 00h 00h 02h 9Ah 00h 4Fh"
params: []
- id: pip_pbp_request
label: PIP/Picture By Picture Request (097-198)
kind: query
command: "03h B0h 00h 00h 02h C5h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "Target: 00h=MODE, 01h=START POSITION, 02h=SUB INPUT/SUB INPUT 1, 09h=SUB INPUT 2, 0Ah=SUB INPUT 3"
- id: edge_blending_mode_request
label: Edge Blending Mode Request (097-243-1)
kind: query
command: "03h B0h 00h 00h 02h DFh 00h 94h"
params: []
- id: eco_mode_set
label: Eco Mode Set (098-8)
kind: action
command: "03h B1h 00h 00h 02h 07h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Value set for the eco mode; see Appendix "Supplementary Information by Command". Exact values UNRESOLVED - referenced but not listed in this excerpt.
- id: lan_projector_name_set
label: LAN Projector Name Set (098-45)
kind: action
command: "03h B1h 00h 00h 12h 2Ch <DATA01> <DATA02> <DATA03> <DATA04> <DATA05> <DATA06> <DATA07> <DATA08> <DATA09> <DATA10> <DATA11> <DATA12> <DATA13> <DATA14> <DATA15> <DATA16> 00h <CKS>"
params:
- name: projector_name
type: string
description: Projector name, up to 16 bytes (DATA01-DATA16), NUL-terminated
- id: pip_pbp_set
label: PIP/Picture By Picture Set (098-198)
kind: action
command: "03h B1h 00h 00h 03h C5h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: "Target: 00h=MODE, 01h=START POSITION, 02h=SUB INPUT/SUB INPUT 1, 09h=SUB INPUT 2, 0Ah=SUB INPUT 3"
- name: DATA02
type: integer
description: "Setting value (interpretation depends on DATA01): MODE 00h=PIP/01h=PbP; START POSITION 00h=TOP-LEFT/01h=TOP-RIGHT/02h=BOTTOM-LEFT/03h=BOTTOM-RIGHT; sub-input values per Appendix"
- id: edge_blending_mode_set
label: Edge Blending Mode Set (098-243-1)
kind: action
command: "03h B1h 00h 00h 03h DFh 00h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: "Setting value: 00h=OFF, 01h=ON"
- id: base_model_type_request
label: Base Model Type Request (305-1)
kind: query
command: "00h BFh 00h 00h 01h 00h C0h"
params: []
- id: serial_number_request
label: Serial Number Request (305-2)
kind: query
command: "00h BFh 00h 00h 02h 01h 06h C8h"
params: []
- id: basic_information_request
label: Basic Information Request (305-3)
kind: query
command: "00h BFh 00h 00h 01h 02h C2h"
params: []
- id: audio_select_set
label: Audio Select Set (319-10)
kind: action
command: "03h C9h 00h 00h 03h 09h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Input terminal value; see Appendix "Supplementary Information by Command". Exact values UNRESOLVED - referenced but not listed in this excerpt.
- name: DATA02
type: integer
description: "Setting value: 00h=audio from terminal specified in DATA01, 01h=BNC, 02h=COMPUTER"
Feedbacks
- id: error_status
type: bitmask
description: 12-byte error information (DATA01-DATA12) returned by 009 ERROR STATUS REQUEST; bits encode cover/fan/temp/power/lamp/formatter/mirror-cover/interlock errors. See source "Error information list" for full bit map.
- id: running_status
type: object
description: 16-byte running status (DATA01-DATA16) returned by 078-2. DATA03 power status (00h=Standby, 01h=Power on, FFh=Not supported); DATA04 cooling process; DATA05 power on/off process; DATA06 operation status (00h=Standby(Sleep), 04h=Power on, 05h=Cooling, 06h=Standby(error), 0Fh=Standby(Power saving), 10h=Network standby).
- id: input_status
type: object
description: 16-byte input signal status (DATA01-DATA16) returned by 078-3, covering signal switch process, signal list number, selection signal type 1/2, signal list type, test pattern display, and content displayed.
- id: mute_status
type: object
description: 16-byte mute status (DATA01-DATA16) returned by 078-4. DATA01 picture mute, DATA02 sound mute, DATA03 onscreen mute, DATA04 forced onscreen mute, DATA05 onscreen display (each 00h=Off, 01h=On).
- id: cover_status
type: enum
values: [normal_cover_open, cover_closed]
description: Returned by 078-6. DATA01 00h=Normal (cover opened), 01h=Cover closed.
- id: lens_information
type: bitmask
description: Byte returned by 053-7 indicating lens operation state per axis (Bit0 lens memory, Bit1 zoom, Bit2 focus, Bit3 lens shift H, Bit4 lens shift V; 0=Stop, 1=During operation).
- id: basic_information
type: object
description: 15-byte status (DATA01-DATA15) returned by 305-3 covering operation status, content displayed, selection signal type 1/2, display signal type, video/sound/onscreen mute, and freeze status.
Variables
# Discrete settable parameters (already modeled as parameterized Actions above):
# - picture brightness/contrast/color/hue/sharpness (030-1)
# - volume (030-2)
# - aspect (030-12)
# - lamp/light adjust (030-15)
# - eco mode (098-8)
# - edge blending on/off (098-243-1)
# - freeze on/off (079)
# - lens position per axis (053, 053-2)
# No additional scalar variables beyond the actions enumerated.
Events
# UNRESOLVED: source does not document any unsolicited (push) notifications.
# Protocol appears strictly request/response (ack/error frames only).
Macros
# UNRESOLVED: source does not describe any multi-step command sequences.
Safety
confirmation_required_for: []
interlocks: []
# Source notes (informational, not formal interlocks):
# - While POWER ON is executing, no other command can be accepted.
# - While POWER OFF is executing (including cooling time), no other command can be accepted.
# - Error 02h 0Dh: "The command cannot be accepted because the power is off."
# - Error 02h 0Fh: "There is no authority necessary for the operation."
# - DATA09 Bit1 of error status: "The interlock switch is open."
# UNRESOLVED: no formal power-on sequencing procedure or safety interlock procedure is documented.
Notes
- Framing: Commands use a fixed-format hex frame. The leading byte encodes message class (00h/01h/02h/03h are requests; 20h/21h/22h/23h are success responses; A0h/A1h/A2h/A3h are error responses).
<ID1>= projector control ID;<ID2>= model code;<CKS>= checksum (low byte of the sum of all preceding bytes). - Checksum example (from source):
20h + 81h + 01h + 60h + 01h + 00h = 103h → CKS = 03h. - Power behavior: POWER ON/OFF block all other commands during execution (incl. cooling). Implementers should poll 078-2 RUNNING STATUS REQUEST to determine readiness.
- Default ID1/ID2: Not stated in this excerpt; typically set per-projector.
- Appendix references: Several commands (018 INPUT SW CHANGE, 030-12 ASPECT ADJUST, 097-8 ECO MODE REQUEST, 098-8 ECO MODE SET, 098-198/097-198 sub-input values, 319-10 input terminal) defer value tables to an "Appendix: Supplementary Information by Command" that is not present in this refined source. Those enum tables are therefore UNRESOLVED.
Spec output above. 53 actions, all hex payloads verbatim. Source is generic NEC BDT140013 manual — does not name Me651 explicitly; flagged UNRESOLVED. Default baud/flow control/model-code/appendix enum tables all marked unresolved per policy.
## Provenance
```yaml
source_domains:
- sharpdisplays.eu
source_urls:
- https://www.sharpdisplays.eu/p/download/cp/Products/Projectors/Shared/CommandLists/NEC-ExternalControlManual-english.pdf
retrieved_at: 2026-06-16T10:09:56.793Z
last_checked_at: 2026-06-18T08:32:14.911Z
Verification Summary
verdict: verified
checked_at: 2026-06-18T08:32:14.911Z
matched_actions: 53
action_count: 53
confidence: medium
summary: "All 53 spec actions matched verbatim against source command reference; transport parameters verified; complete bidirectional coverage. (13 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "source is a generic \"Projector Control Command Reference Manual\" (BDT140013) and does not state the model name Me651; model mapping assumed by operator. Model code (ID2) value for this model not stated in source."
- "default baud not stated; source lists supported set 115200/38400/19200/9600/4800 bps"
- "flow control not stated (RTS/CTS pins present on connector)"
- "source does not document any unsolicited (push) notifications."
- "source does not describe any multi-step command sequences."
- "no formal power-on sequencing procedure or safety interlock procedure is documented."
- "default baud rate not stated (5 options listed)."
- "serial flow control not stated (RTS/CTS pins wired on D-SUB 9P)."
- "model code (ID2) value for Me651 not stated in source."
- "default control ID (ID1) not stated."
- "firmware version compatibility not stated."
- "input terminal / aspect / eco-mode / sub-input enum value tables referenced but not included in this source excerpt."
- "source document is a generic NEC projector command reference (BDT140013 Rev 7.1); it does not name Me651 explicitly — model association provided by operator."