Summary
RS-232C and TCP (wired/wireless LAN) control spec for a Sharp/NEC projector, derived from the "Projector Control Command Reference Manual" (BDT140013 Rev 7.1). Commands are binary frames with a leading header byte, model/control ID, length, data payload, and a checksum byte (low-order 8 bits of the sum of preceding bytes).
Transport
protocols:
- serial
- tcp
serial:
baud_rate: 115200 # source lists 115200/38400/19200/9600/4800; one value shown, others valid
# UNRESOLVED: source does not state a single default baud rate; populated with highest option
data_bits: 8
parity: none
stop_bits: 1
flow_control: none # UNRESOLVED: flow_control not stated in source (full-duplex communication mode stated)
addressing:
port: 7142
auth:
type: none # inferred: no auth procedure in source
Traits
traits:
- powerable # inferred from POWER ON / POWER OFF commands
- queryable # inferred from numerous REQUEST commands
- levelable # inferred from PICTURE/VOLUME/LAMP adjust commands
- routable # inferred from INPUT SW CHANGE and audio select
Actions
# Frame format: <HEADER> <ID1> <ID2> <LEN> <DATA...> <CKS>
# ID1 = control ID set on projector; ID2 = model code (varies by model, UNRESOLVED).
# CKS = checksum = low-order byte of sum of all preceding bytes.
# Commands below show the literal request payloads from the source verbatim, with
# parameter placeholders (<DATA...>, <ID1>, <ID2>, <CKS>) preserved as written.
- id: cmd_009_error_status_request
label: 009 Error Status Request
kind: query
command: "00h 88h 00h 00h 00h 88h"
params: []
- id: cmd_015_power_on
label: 015 Power On
kind: action
command: "02h 00h 00h 00h 00h 02h"
params: []
- id: cmd_016_power_off
label: 016 Power Off
kind: action
command: "02h 01h 00h 00h 00h 03h"
params: []
- id: cmd_018_input_sw_change
label: 018 Input SW Change
kind: action
command: "02h 03h 00h 00h 02h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Input terminal code (see Appendix "Supplementary Information by Command"; e.g. 06h = video port)
- id: cmd_020_picture_mute_on
label: 020 Picture Mute On
kind: action
command: "02h 10h 00h 00h 00h 12h"
params: []
- id: cmd_021_picture_mute_off
label: 021 Picture Mute Off
kind: action
command: "02h 11h 00h 00h 00h 13h"
params: []
- id: cmd_022_sound_mute_on
label: 022 Sound Mute On
kind: action
command: "02h 12h 00h 00h 00h 14h"
params: []
- id: cmd_023_sound_mute_off
label: 023 Sound Mute Off
kind: action
command: "02h 13h 00h 00h 00h 15h"
params: []
- id: cmd_024_onscreen_mute_on
label: 024 Onscreen Mute On
kind: action
command: "02h 14h 00h 00h 00h 16h"
params: []
- id: cmd_025_onscreen_mute_off
label: 025 Onscreen Mute Off
kind: action
command: "02h 15h 00h 00h 00h 17h"
params: []
- id: cmd_030_1_picture_adjust
label: 030-1 Picture Adjust
kind: action
command: "03h 10h 00h 00h 05h <DATA01> FFh <DATA02> - <DATA04> <CKS>"
params:
- name: DATA01
type: integer
description: Adjustment target (00h=Brightness, 01h=Contrast, 02h=Color, 03h=Hue, 04h=Sharpness)
- name: DATA02
type: integer
description: Adjustment mode (00h=absolute, 01h=relative)
- name: DATA03
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA04
type: integer
description: Adjustment value (high-order 8 bits)
- id: cmd_030_2_volume_adjust
label: 030-2 Volume Adjust
kind: action
command: "03h 10h 00h 00h 05h 05h 00h <DATA01> - <DATA03> <CKS>"
params:
- name: DATA01
type: integer
description: Adjustment mode (00h=absolute, 01h=relative)
- name: DATA02
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA03
type: integer
description: Adjustment value (high-order 8 bits)
- id: cmd_030_12_aspect_adjust
label: 030-12 Aspect Adjust
kind: action
command: "03h 10h 00h 00h 05h 18h 00h 00h <DATA01> 00h <CKS>"
params:
- name: DATA01
type: integer
description: Value set for the aspect (see Appendix "Supplementary Information by Command")
- id: cmd_030_15_other_adjust
label: 030-15 Other Adjust
kind: action
command: "03h 10h 00h 00h 05h <DATA01> - <DATA05> <CKS>"
params:
- name: DATA01
type: integer
description: Adjustment target high byte (96h = LAMP ADJUST / LIGHT ADJUST)
- name: DATA02
type: integer
description: Adjustment target low byte (FFh when DATA01=96h)
- name: DATA03
type: integer
description: Adjustment mode (00h=absolute, 01h=relative)
- name: DATA04
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA05
type: integer
description: Adjustment value (high-order 8 bits)
- id: cmd_037_information_request
label: 037 Information Request
kind: query
command: "03h 8Ah 00h 00h 00h 8Dh"
params: []
- id: cmd_037_3_filter_usage_information_request
label: 037-3 Filter Usage Information Request
kind: query
command: "03h 95h 00h 00h 00h 98h"
params: []
- id: cmd_037_4_lamp_information_request_3
label: 037-4 Lamp Information Request 3
kind: query
command: "03h 96h 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Lamp selector (00h=Lamp 1, 01h=Lamp 2; Lamp 2 only on two-lamp models)
- name: DATA02
type: integer
description: Content (01h=usage time seconds, 04h=remaining life %)
- id: cmd_037_6_carbon_savings_information_request
label: 037-6 Carbon Savings Information Request
kind: query
command: "03h 9Ah 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Content (00h=Total Carbon Savings, 01h=Carbon Savings during operation)
- id: cmd_050_remote_key_code
label: 050 Remote Key Code
kind: action
command: "02h 0Fh 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Key code low byte (see Key code list in source, e.g. 02h=POWER ON, 05h=AUTO, 0Bh=ENTER)
- name: DATA02
type: integer
description: Key code high byte (always 00h in listed codes)
- id: cmd_051_shutter_close
label: 051 Shutter Close
kind: action
command: "02h 16h 00h 00h 00h 18h"
params: []
- id: cmd_052_shutter_open
label: 052 Shutter Open
kind: action
command: "02h 17h 00h 00h 00h 19h"
params: []
- id: cmd_053_lens_control
label: 053 Lens Control
kind: action
command: "02h 18h 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Adjustment target (06h = Periphery Focus)
- name: DATA02
type: integer
description: Drive command (00h=stop, 01h=+1s, 02h=+0.5s, 03h=+0.25s, 7Fh=+continuous, 81h=-continuous, FDh=-0.25s, FEh=-0.5s, FFh=-1s)
- id: cmd_053_1_lens_control_request
label: 053-1 Lens Control Request
kind: query
command: "02h 1Ch 00h 00h 02h <DATA01> 00h <CKS>"
params:
- name: DATA01
type: integer
description: Adjustment target (same codes as cmd_053 DATA01)
- id: cmd_053_2_lens_control_2
label: 053-2 Lens Control 2
kind: action
command: "02h 1Dh 00h 00h 04h <DATA01> - <DATA04> <CKS>"
params:
- name: DATA01
type: integer
description: Adjustment target (FFh=Stop; otherwise same target codes)
- name: DATA02
type: integer
description: Adjustment mode (00h=absolute, 02h=relative)
- name: DATA03
type: integer
description: Adjustment value (low-order 8 bits)
- name: DATA04
type: integer
description: Adjustment value (high-order 8 bits)
- id: cmd_053_3_lens_memory_control
label: 053-3 Lens Memory Control
kind: action
command: "02h 1Eh 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Operation (00h=MOVE, 01h=STORE, 02h=RESET)
- id: cmd_053_4_reference_lens_memory_control
label: 053-4 Reference Lens Memory Control
kind: action
command: "02h 1Fh 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Operation (00h=MOVE, 01h=STORE, 02h=RESET)
- id: cmd_053_5_lens_memory_option_request
label: 053-5 Lens Memory Option Request
kind: query
command: "02h 20h 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Option (00h=LOAD BY SIGNAL, 01h=FORCED MUTE)
- id: cmd_053_6_lens_memory_option_set
label: 053-6 Lens Memory Option Set
kind: action
command: "02h 21h 00h 00h 02h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Option (00h=LOAD BY SIGNAL, 01h=FORCED MUTE)
- name: DATA02
type: integer
description: Setting value (00h=OFF, 01h=ON)
- id: cmd_053_7_lens_information_request
label: 053-7 Lens Information Request
kind: query
command: "02h 22h 00h 00h 01h 00h 25h"
params: []
- id: cmd_053_10_lens_profile_set
label: 053-10 Lens Profile Set
kind: action
command: "02h 27h 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Profile number (00h=Profile 1, 01h=Profile 2)
- id: cmd_053_11_lens_profile_request
label: 053-11 Lens Profile Request
kind: query
command: "02h 28h 00h 00h 00h 2Ah"
params: []
- id: cmd_060_1_gain_parameter_request_3
label: 060-1 Gain Parameter Request 3
kind: query
command: "03h 05h 00h 00h 03h <DATA01> 00h 00h <CKS>"
params:
- name: DATA01
type: integer
description: Adjusted value name (00h=Brightness, 01h=Contrast, 02h=Color, 03h=Hue, 04h=Sharpness, 05h=Volume, 96h=Lamp/Light Adjust)
- id: cmd_078_1_setting_request
label: 078-1 Setting Request
kind: query
command: "00h 85h 00h 00h 01h 00h 86h"
params: []
- id: cmd_078_2_running_status_request
label: 078-2 Running Status Request
kind: query
command: "00h 85h 00h 00h 01h 01h 87h"
params: []
- id: cmd_078_3_input_status_request
label: 078-3 Input Status Request
kind: query
command: "00h 85h 00h 00h 01h 02h 88h"
params: []
- id: cmd_078_4_mute_status_request
label: 078-4 Mute Status Request
kind: query
command: "00h 85h 00h 00h 01h 03h 89h"
params: []
- id: cmd_078_5_model_name_request
label: 078-5 Model Name Request
kind: query
command: "00h 85h 00h 00h 01h 04h 8Ah"
params: []
- id: cmd_078_6_cover_status_request
label: 078-6 Cover Status Request
kind: query
command: "00h 85h 00h 00h 01h 05h 8Bh"
params: []
- id: cmd_079_freeze_control
label: 079 Freeze Control
kind: action
command: "01h 98h 00h 00h 01h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Freeze state (01h=ON, 02h=OFF)
- id: cmd_084_information_string_request
label: 084 Information String Request
kind: query
command: "00h D0h 00h 00h 03h 00h <DATA01> 01h <CKS>"
params:
- name: DATA01
type: integer
description: Information type (03h=Horizontal sync frequency, 04h=Vertical sync frequency)
- id: cmd_097_8_eco_mode_request
label: 097-8 Eco Mode Request
kind: query
command: "03h B0h 00h 00h 01h 07h BBh"
params: []
- id: cmd_097_45_lan_projector_name_request
label: 097-45 LAN Projector Name Request
kind: query
command: "03h B0h 00h 00h 01h 2Ch E0h"
params: []
- id: cmd_097_155_lan_mac_address_status_request2
label: 097-155 LAN MAC Address Status Request 2
kind: query
command: "03h B0h 00h 00h 02h 9Ah 00h 4Fh"
params: []
- id: cmd_097_198_pip_picture_by_picture_request
label: 097-198 PIP/Picture by Picture Request
kind: query
command: "03h B0h 00h 00h 02h C5h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Item (00h=MODE, 01h=START POSITION, 02h=SUB INPUT/SUB INPUT 1, 09h=SUB INPUT 2, 0Ah=SUB INPUT 3)
- id: cmd_097_243_1_edge_blending_mode_request
label: 097-243-1 Edge Blending Mode Request
kind: query
command: "03h B0h 00h 00h 02h DFh 00h 94h"
params: []
- id: cmd_098_8_eco_mode_set
label: 098-8 Eco Mode Set
kind: action
command: "03h B1h 00h 00h 02h 07h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Value set for the eco mode (see Appendix "Supplementary Information by Command")
- id: cmd_098_45_lan_projector_name_set
label: 098-45 LAN Projector Name Set
kind: action
command: "03h B1h 00h 00h 12h 2Ch <DATA01> - <DATA16> 00h <CKS>"
params:
- name: DATA01_to_DATA16
type: string
description: Projector name (up to 16 bytes, NUL-terminated)
- id: cmd_098_198_pip_picture_by_picture_set
label: 098-198 PIP/Picture by Picture Set
kind: action
command: "03h B1h 00h 00h 03h C5h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Item (00h=MODE, 01h=START POSITION, 02h=SUB INPUT/SUB INPUT 1, 09h=SUB INPUT 2, 0Ah=SUB INPUT 3)
- name: DATA02
type: integer
description: Setting value (e.g. MODE: 00h=PIP/01h=PICTURE BY PICTURE; START POSITION: 00h=TOP-LEFT..03h=BOTTOM-RIGHT; sub input values per appendix)
- id: cmd_098_243_1_edge_blending_mode_set
label: 098-243-1 Edge Blending Mode Set
kind: action
command: "03h B1h 00h 00h 03h DFh 00h <DATA01> <CKS>"
params:
- name: DATA01
type: integer
description: Setting value (00h=OFF, 01h=ON)
- id: cmd_305_1_base_model_type_request
label: 305-1 Base Model Type Request
kind: query
command: "00h BFh 00h 00h 01h 00h C0h"
params: []
- id: cmd_305_2_serial_number_request
label: 305-2 Serial Number Request
kind: query
command: "00h BFh 00h 00h 02h 01h 06h C8h"
params: []
- id: cmd_305_3_basic_information_request
label: 305-3 Basic Information Request
kind: query
command: "00h BFh 00h 00h 01h 02h C2h"
params: []
- id: cmd_319_10_audio_select_set
label: 319-10 Audio Select Set
kind: action
command: "03h C9h 00h 00h 03h 09h <DATA01> <DATA02> <CKS>"
params:
- name: DATA01
type: integer
description: Input terminal (see Appendix "Supplementary Information by Command")
- name: DATA02
type: integer
description: Setting value (00h=terminal specified in DATA01, 01h=BNC, 02h=COMPUTER)
Feedbacks
# Generic response framing (applies to every action above):
# Success (no data): <2xh> <MT> <ID1> <ID2> <LEN=00h> <CKS>
# Success (with data): <2xh> <MT> <ID1> <ID2> <LEN> <DATA...> <CKS>
# Failure: <Axh> <MT> <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>
# where MT = message-type byte mirrored from the request, and x = request header nibble.
# Per-command ACK payloads are listed verbatim in the source; representative samples:
- id: ack_009_error_status
type: binary
values: ["A0h 88h <ID1> <ID2> 0Ch <DATA01>-<DATA12> <CKS>"]
notes: DATA01-DATA12 bitfield error info; bit=0 normal, bit=1 error.
- id: ack_015_power_on
type: binary
values: ["22h 00h <ID1> <ID2> 00h <CKS>"]
- id: ack_016_power_off
type: binary
values: ["22h 01h <ID1> <ID2> 00h <CKS>"]
- id: ack_018_input_sw_change
type: binary
values: ["22h 03h <ID1> <ID2> 01h <DATA01> <CKS>", "FFh on error (no switch made)"]
- id: ack_030_1_picture_adjust
type: binary
values: ["23h 10h <ID1> <ID2> 02h <DATA01> <DATA02> <CKS> (0000h=success)"]
- id: ack_050_remote_key_code
type: binary
values: ["22h 0Fh <ID1> <ID2> 01h <DATA01> <CKS>", "FFh on error"]
- id: ack_053_lens_control
type: binary
values: ["22h 18h <ID1> <ID2> 01h <DATA01> <CKS>", "FFh on error"]
- id: ack_053_3_lens_memory_control
type: binary
values: ["22h 1Eh <ID1> <ID2> 02h <DATA01> <DATA02> <CKS>", "FFh on error"]
- id: ack_079_freeze_control
type: binary
values: ["21h 98h <ID1> <ID2> 01h <DATA01> <CKS>"]
- id: ack_098_8_eco_mode_set
type: binary
values: ["23h B1h <ID1> <ID2> 02h 07h <DATA01> <CKS>"]
- id: ack_098_198_pip_picture_by_picture_set
type: binary
values: ["23h B1h <ID1> <ID2> 03h C5h <DATA01> <DATA02> <CKS>"]
- id: ack_098_243_1_edge_blending_mode_set
type: binary
values: ["23h B1h <ID1> <ID2> 03h DFh 00h <DATA01> <CKS>"]
- id: ack_319_10_audio_select_set
type: binary
values: ["23h C9h <ID1> <ID2> 03h 09h <DATA01> <DATA02> <CKS> (00h=success, 01h=error)"]
- id: error_response_generic
type: binary
values: ["<Axh> <MT> <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>"]
notes: |
ERR1/ERR2 code pairs (source §2.4):
00h/00h=unrecognized cmd; 00h/01h=cmd not supported by model;
01h/00h=invalid value; 01h/01h=invalid input terminal; 01h/02h=invalid language;
02h/00h=memory allocation error; 02h/02h=memory in use; 02h/03h=value cannot be set;
02h/04h=forced onscreen mute on; 02h/06h=viewer error; 02h/07h=no signal;
02h/08h=test pattern/filter displayed; 02h/09h=no PC card; 02h/0Ah=memory op error;
02h/0Ch=entry list displayed; 02h/0Dh=command rejected (power off);
02h/0Eh=execution failed; 02h/0Fh=no authority;
03h/00h=incorrect gain number; 03h/01h=invalid gain; 03h/02h=adjustment failed.
# UNRESOLVED: complete per-command success-ACK payloads for queries (037, 053-1, 060-1,
# 078-*, 084, 097-*, 305-*) are documented in source §3 and reproduced in the command
# `command:` field above; only representative ACKs are duplicated here.
Variables
# Query-return parameters (state values the device reports, not directly set).
# Each corresponds to a `kind: query` action's response DATA fields.
- id: var_power_status
type: enum
source: 078-2 DATA03 / 305-3 DATA01
values: [standby, power_on, cooling, standby_error, standby_power_saving, network_standby, not_supported]
- id: var_operation_status
type: enum
source: 078-2 DATA06
values: [standby_sleep, power_on, cooling, standby_error, standby_power_saving, network_standby]
- id: var_cooling_process
type: enum
source: 078-2 DATA04
values: [not_executed, during_execution, not_supported]
- id: var_power_on_off_process
type: enum
source: 078-2 DATA05
values: [not_executed, during_execution, not_supported]
- id: var_picture_mute
type: enum
source: 078-4 DATA01 / 305-3 DATA06
values: [off, on]
- id: var_sound_mute
type: enum
source: 078-4 DATA02 / 305-3 DATA07
values: [off, on]
- id: var_onscreen_mute
type: enum
source: 078-4 DATA03 / 305-3 DATA08
values: [off, on]
- id: var_forced_onscreen_mute
type: enum
source: 078-4 DATA04
values: [off, on]
- id: var_freeze_status
type: enum
source: 305-3 DATA09
values: [off, on]
- id: var_cover_status
type: enum
source: 078-6 DATA01
values: [normal_opened, closed]
- id: var_selection_signal_type_2
type: enum
source: 078-3 DATA04 / 305-3 DATA04
values: [computer, video, s_video, component, dvi_d, hdmi, displayport, viewer_1_5, viewer_6_10, not_source_input]
- id: var_content_displayed
type: enum
source: 078-3 DATA09 / 305-3 DATA02
values: [video_signal, no_signal, viewer, test_pattern, lan_displayed, test_pattern_user, signal_switching]
- id: var_lens_operation
type: bitfield
source: 053-7 DATA01
values: [lens_memory, zoom, focus, lens_shift_h, lens_shift_v]
- id: var_lamp_usage_time_seconds
type: integer
source: 037 DATA83-86 / 037-4 DATA03-06
- id: var_filter_usage_time_seconds
type: integer
source: 037 DATA87-90 / 037-3 DATA01-04
- id: var_filter_alarm_start_time_seconds
type: integer
source: 037-3 DATA05-08
- id: var_lamp_remaining_life_pct
type: integer
source: 037-4 (DATA02=04h) DATA03-06
- id: var_carbon_savings_kg
type: number
source: 037-6 DATA02-05
- id: var_model_name
type: string
source: 078-5 DATA01-32
- id: var_projector_name
type: string
source: 097-45 DATA01-17
- id: var_mac_address
type: string
source: 097-155 DATA01-06
- id: var_serial_number
type: string
source: 305-2 DATA01-16
- id: var_base_model_type
type: binary
source: 305-1 DATA01-02 / DATA12-13
- id: var_horizontal_sync_frequency
type: string
source: 084 (DATA01=03h) DATA03-??
- id: var_vertical_sync_frequency
type: string
source: 084 (DATA01=04h) DATA03-??
- id: var_sound_function_available
type: enum
source: 078-1 DATA04
values: [not_available, available]
- id: var_lens_memory_option_load_by_signal
type: enum
source: 053-5/053-6 (DATA01=00h) DATA02
values: [off, on]
- id: var_lens_memory_option_forced_mute
type: enum
source: 053-5/053-6 (DATA01=01h) DATA02
values: [off, on]
- id: var_lens_profile
type: enum
source: 053-10/053-11 DATA01
values: [profile_1, profile_2]
- id: var_eco_mode
type: integer
source: 097-8/098-8 DATA01
notes: meaning varies by model (Light mode / Lamp mode); see Appendix "Supplementary Information by Command"
- id: var_edge_blending_mode
type: enum
source: 097-243-1/098-243-1 DATA01
values: [off, on]
- id: var_pip_pbp_mode
type: enum
source: 097-198/098-198 (DATA01=00h) DATA02
values: [pip, picture_by_picture]
- id: var_pip_pbp_start_position
type: enum
source: 097-198/098-198 (DATA01=01h) DATA02
values: [top_left, top_right, bottom_left, bottom_right]
- id: var_gain_adjustment_status
type: enum
source: 060-1 DATA01
values: [display_not_possible, adjustment_not_possible, adjustment_possible, gain_does_not_exist]
Events
# Source documents no unsolicited notifications. All responses are solicited ACKs to
# commands listed in Actions/Feedbacks.
# UNRESOLVED: no async event mechanism described in source.
Macros
# UNRESOLVED: source documents no multi-step command sequences as named macros.
Safety
confirmation_required_for: []
interlocks:
- id: power_on_lockout
description: While POWER ON is executing, no other command can be accepted (source §3.2).
- id: power_off_lockout
description: While POWER OFF is executing (including cooling time), no other command can be accepted (source §3.3).
- id: error_02_0d_power_off
description: Commands are rejected with ERR1=02h/ERR2=0Dh when power is off.
- id: error_02_0f_no_authority
description: Operations without required authority fail with ERR1=02h/ERR2=0Fh.
# UNRESOLVED: source describes no electrical safety interlocks, power-on sequencing
# procedures, or mandatory operator confirmation steps beyond the lockouts above.
Notes
- Source is the Sharp/NEC "Projector Control Command Reference Manual", document BDT140013 Revision 7.1. It is a generic projector-family manual; the EA242F BK SV is named only in the ingest request, not in the source body.
- All commands are binary frames over RS-232C (D-SUB 9P, cross cable) or TCP port 7142 (wired/wireless LAN). Full-duplex.
- Checksum = low-order byte of the unsigned sum of all preceding bytes (source §2.2 worked example: 20h+81h+01h+60h+01h+00h=103h → CKS=03h).
- ID1 is the projector's configured control ID; ID2 is the per-model code. Neither is enumerated for the EA242F BK SV in this source.
- Lamp/filter usage times update at 1-minute granularity despite 1-second resolution (source §3.15, §3.17).
- Negative lamp remaining-life % is returned once the replacement deadline is exceeded (source §3.17).
- PICTURE/SOUND/ONSCREEN mute auto-clear on input terminal switch or video signal switch (source §3.5, §3.7, §3.9); SOUND mute also clears on volume adjustment.
- Lens control continuous-drive values (7Fh / 81h) require a follow-up 00h stop command (source §3.22).
Provenance
source_domains:
- sharpdisplays.eu
source_urls:
- https://www.sharpdisplays.eu/p/download/cp/Products/Projectors/Shared/CommandLists/NEC-ExternalControlManual-english.pdf
retrieved_at: 2026-06-17T06:15:01.934Z
last_checked_at: 2026-06-17T19:46:43.850Z
Verification Summary
verdict: verified
checked_at: 2026-06-17T19:46:43.850Z
matched_actions: 53
action_count: 53
confidence: medium
summary: "All 53 spec actions verified as literal hex-command matches against source; transport parameters all supported. (16 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "The source document is a generic projector command reference and does not explicitly name the \"EA242F BK SV\" model. Model name in compatible_with is taken from the ingest request, not from a verbatim statement in the source. Confirm the device actually implements this command set before publishing."
- "firmware version compatibility not stated in source"
- "ID2 (model code) value not enumerated in source — varies by model"
- "input-terminal value table (DATA01 of command 018, etc.) is referenced as \"Supplementary Information by Command\" appendix, which is not present in the refined source excerpt"
- "source does not state a single default baud rate; populated with highest option"
- "flow_control not stated in source (full-duplex communication mode stated)"
- "complete per-command success-ACK payloads for queries (037, 053-1, 060-1,"
- "no async event mechanism described in source."
- "source documents no multi-step command sequences as named macros."
- "source describes no electrical safety interlocks, power-on sequencing"
- "input-terminal value table (referenced by Appendix \"Supplementary Information by Command\" for commands 018, 030-12, 098-198 sub-input, 319-10) not present in refined source."
- "base-model-type code table (305-1, 078-1) referenced but absent from refined source."
- "eco-mode value table (097-8 / 098-8) referenced but absent."
- "aspect value table (030-12) referenced but absent."
- "complete serial flow_control setting not stated (only \"Full duplex\" communication mode stated)."
- "serial default baud rate not stated; five options listed (115200/38400/19200/9600/4800)."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0