Summary
RS-232C and IP control spec for Sharp PN-UH601/PN-UH701 professional LCD monitors. Commands are 8 ASCII codes terminated with CR; PC sends command, monitor replies with OK/ERR response.
Transport
protocols:
- serial
- tcp
addressing:
port: null # UNRESOLVED: TCP port not stated in source ("Set a port number on the TV menu (Control port)")
serial:
baud_rate: 115200
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: password # source: "When you set your ID and password on the TV menu, you need to enter them as soon as you connect to the TV"
Traits
- powerable
- routable
- queryable
- levelable
Actions
- id: power_off
label: Power Off (Standby)
kind: action
command: "POWR0___" # PO WR 0 _ _ _ (Power Off)
params: []
- id: power_on
label: Power On
kind: action
command: "POWR1___" # PO WR 1 _ _ _ (Power On; requires Quick Start Mode = On)
params: []
- id: power_on_low_baud
label: Power On via RS-232C at 9,600 baud
kind: action
command: "POWR1___" # 8 ASCII codes + CR
params: []
notes: "Use when Quick mode is Off and display power is off. Set PC baud to 9,600 before sending. Baud auto-reverts after."
- id: input_toggle
label: Input Toggle
kind: action
command: "ITGD____" # IT GD _ _ _ _
params: []
- id: input_select_tv
label: Input Select TV
kind: action
command: "ITVD0___" # IT VD 0 _ _ _
params: []
- id: input_select
label: Input Select (0-5)
kind: action
command: "IAVD{0-5}__" # IA VD * _ _ _ (0:TV, 1:HDMI1, 2:HDMI2, 3:VIDEO, 4:USB, 5:Home Network)
params:
- name: input
type: integer
description: 0=TV, 1=HDMI IN 1, 2=HDMI IN 2, 3=VIDEO IN, 4=USB, 5=Home Network
- id: wide_mode
label: Wide Mode
kind: action
command: "WIDE{**}_" # WI DE * * _ _ (0:Toggle, 1:Normal, 2:Zoom14:9, 3:Panorama, 4:Full, 5:Cinema16:9, 6:Cinema14:9, 10:DotByDot, 14:Overscan)
params:
- name: mode
type: integer
description: 0-14 per CONTROL CONTENTS
- id: av_mode
label: AV Mode Selection
kind: action
command: "AVMD{*}___" # AV MD * _ _ _ (0:Toggle, 1:STANDARD, 2:MOVIE, 4:USER, 5:DYNAMIC, 6:DYNAMIC(Fixed))
params:
- name: mode
type: integer
description: 0,1,2,4,5,6
- id: mute
label: Mute
kind: action
command: "MUTE{*}___" # MU TE * _ _ _ (0:Toggle, 1:On, 2:Off)
params:
- name: state
type: integer
description: 0=Toggle, 1=On, 2=Off
- id: volume_set
label: Volume Set
kind: action
command: "VOLM{***}_" # VO LM * * * _ Volume 0-100
params:
- name: level
type: integer
description: Volume 0-100
- id: channel_analog
label: Direct Channel (Analog)
kind: action
command: "DCCH{***}_" # DC CH * * * _ Channel 1-135
params:
- name: channel
type: integer
description: Analog channel 1-135 (Air 2-69, Cable 1-135)
- id: surround
label: Surround
kind: action
command: "ACSU{*}___" # AC SU * _ _ _ (0:Toggle, 1:On, 2:Off)
params:
- name: state
type: integer
description: 0=Toggle, 1=On, 2=Off
- id: audio_selection
label: Audio Selection (Toggle)
kind: action
command: "ACHA____" # AC HA _ _ _ _
params: []
- id: channel_digital_air
label: Direct Channel (Digital Air, two-part)
kind: action
command: "DA2P{****}" # DA 2P * * * * (0100-9999)
params:
- name: channel
type: integer
description: Two-part number 0100-9999
- id: sleep_timer
label: Sleep Timer
kind: action
command: "OFTM{*}___" # OF TM * _ _ _ (0:Off, 1:30min, 2:1h, 3:1h30, 4:2h, 5:2h30)
params:
- name: setting
type: integer
description: 0=Off, 1=0:30, 2=1:00, 3=1:30, 4=2:00, 5=2:30
- id: channel_digital_cable_major
label: Direct Channel (Digital Cable, major)
kind: action
command: "DC2U{***}_" # DC 2U * * * _ (1-999)
params:
- name: major
type: integer
description: Major channel 1-999
- id: channel_digital_cable_minor
label: Direct Channel (Digital Cable, minor)
kind: action
command: "DC2L{***}_" # DC 2L * * * _ (0-999)
params:
- name: minor
type: integer
description: Minor channel 0-999
- id: channel_digital_cable_one_part_low
label: Direct Channel (Digital Cable, one-part <10000)
kind: action
command: "DC10{****}" # DC 10 * * * * (0-6383)
params:
- name: channel
type: integer
description: One-part number 0-6383
- id: channel_digital_cable_one_part_high
label: Direct Channel (Digital Cable, one-part >=10000)
kind: action
command: "DC11{****}" # DC 11 * * * * (0-9999)
params:
- name: channel
type: integer
description: One-part number 0-9999
- id: channel_up
label: Channel Up
kind: action
command: "CHUP____" # CH UP _ _ _ _
params: []
- id: channel_down
label: Channel Down
kind: action
command: "CHDW____" # CH DW _ _ _ _
params: []
- id: closed_caption_toggle
label: Closed Caption Toggle
kind: action
command: "CLCPx___" # CL CP x _ _ _ (x = any digit; toggle)
params: []
- id: device_name
label: Device Name (Query)
kind: query
command: "TVNM1___" # TV NM 1 _ _ _ _
params: []
- id: model_name
label: Model Name (Query)
kind: query
command: "MNRD1___" # MN RD 1 _ _ _ _
params: []
- id: software_version
label: Software Version (Query)
kind: query
command: "SWVN1___" # SW VN 1 _ _ _ _
params: []
- id: ip_protocol_version
label: IP Protocol Version (Query)
kind: query
command: "IPPV1___" # IP PV 1 _ _ _ _
params: []
- id: remote_key
label: Remote Control Button
kind: action
command: "RCKY{**}_" # RC KY * * _ _ (0-9:0-9, 10:DOT, 12:POWER, 13:DISPLAY, 23:OPTION, 24:SLEEP, 31:MUTE, 32:VOL-, 33:VOL+, 34:CHup, 35:CHdn, 36:INPUT, 38:MENU, 39:APPS, 40:ENTER, 45:RETURN, 46:EXIT, 49:AUDIO, 50:A/red, 51:B/green, 52:C/blue, 53:D/yellow, 61:MANUAL)
params:
- name: key
type: integer
description: Key code per CONTROL CONTENTS
- id: baud_rate_9600
label: Set RS-232C Baud Rate 9,600
kind: action
command: "BAUD0096" # BA UD 0 0 9 6
params: []
- id: baud_rate_115200
label: Set RS-232C Baud Rate 115,200
kind: action
command: "BAUD1152" # BA UD 1 1 5 2
params: []
Feedbacks
# Response format details not present in refined source (picture omitted)
# Per source, monitor returns OK on success or ERR when parameter out of range
- id: response_ok
type: enum
values: [ok]
- id: response_err
type: enum
values: [err]
description: Returned when input parameter is not within adjustable range
Variables
# Source defines command-parameterized values (volume, channel, mode enums)
# No persistent variable setters beyond per-command parameters
Events
# UNRESOLVED: unsolicited notifications not documented in source
Macros
# UNRESOLVED: no multi-step sequences described in source
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: source notes Power On requires "Quick Start Mode" = On; this is a
# device-side menu precondition rather than a host-side interlock. No explicit
# safety warnings or interlocks documented.
Notes
- IP control uses TCP; Telnet and SSH must NOT be selected as service (per source: "None (Do not select Telnet or SSH)").
- TCP port is configured on the TV menu ("Control port") — not stated as a fixed value in source.
- TCP session times out after 3 minutes of no communication.
- TCP requires login ID + password set on TV menu (entered on connect).
- Command framing: 8 ASCII codes + CR. Underbar
_in parameter column = space. Asterisk*= user-supplied value from CONTROL CONTENTS. - Pictures showing exact command frame, parameter layout, and response code format were omitted from refined source; only the table of opcodes is fully present.
- RS-232C connects via SERVICE ONLY minijack terminal (requires conversion cable, not standard D-sub).
- Baud rate change commands exist; Power-On via RS-232C at 9,600 baud is supported when display is off and Quick mode is Off (baud auto-reverts after).
- Wake-on-LAN (Magic Packet) supported when Wake on Wi-Fi/LAN = Enable and Quick Start = Off.
<!-- UNRESOLVED: TCP port number not stated in source; firmware compatibility ranges not stated; pictures showing command/response frame format were omitted from refined source -->
## Provenance
```yaml
source_domains:
- business.sharpusa.com
source_urls:
- https://business.sharpusa.com/portals/0/downloads/Manuals/PN-UH601_701_Operation_Manual.pdf
retrieved_at: 2026-06-12T04:58:19.970Z
last_checked_at: 2026-06-12T19:41:20.869Z
Verification Summary
verdict: verified
checked_at: 2026-06-12T19:41:20.869Z
matched_actions: 29
action_count: 29
confidence: medium
summary: "All 29 spec actions map to source command table; transport parameters confirmed; full bidirectional coverage. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "pictures showing command format, parameter layout, and response code format were omitted from refined source"
- "TCP port not stated in source (\"Set a port number on the TV menu (Control port)\")"
- "unsolicited notifications not documented in source"
- "no multi-step sequences described in source"
- "source notes Power On requires \"Quick Start Mode\" = On; this is a"
- "TCP port number not stated in source; firmware compatibility ranges not stated; pictures showing command/response frame format were omitted from refined source"