Summary

Sharp LCC6500 Series LCD monitor controlled via RS-232C and TCP/IP. Protocol uses a binary-encoded ASCII message format with Header, Message, Check Code (BCC), and Delimiter structure. Supports VCP-style get/set operations and CTL command messages.

Transport

protocols:
  - serial
  - tcp
serial:
  baud_rate: 9600
  data_bits: 8
  parity: none
  stop_bits: 1
  flow_control: null
addressing:
  port: 7142
auth:
  type: none

Traits

- powerable
- queryable
- levelable
- routable

Actions

- id: save_current_settings
  label: Save Current Settings
  kind: action
  params: []

- id: get_timing_report
  label: Get Timing Report
  kind: action
  params: []

- id: power_status_read
  label: Power Status Read
  kind: action
  params: []

- id: power_control
  label: Power Control
  kind: action
  params:
    - name: state
      type: integer
      description: Power state (on/off)

- id: serial_no_read
  label: Serial Number Read
  kind: action
  params: []

- id: model_name_read
  label: Model Name Read
  kind: action
  params: []

- id: mac_address_read
  label: MAC Address Read
  kind: action
  params: []

- id: tv_channel_read
  label: Direct TV Channel Read
  kind: action
  params: []

- id: tv_channel_write
  label: Direct TV Channel Write
  kind: action
  params:
    - name: channel
      type: integer

- id: remote_control_data
  label: Remote Control Data Code
  kind: action
  params:
    - name: data_code
      type: integer

- id: firmware_version_read
  label: Firmware Version Read
  kind: action
  params: []

- id: input_name_read
  label: Input Name Read
  kind: action
  params:
    - name: terminal
      type: integer

- id: input_name_write
  label: Input Name Write
  kind: action
  params:
    - name: terminal
      type: integer
    - name: name
      type: string

- id: input_name_reset
  label: Input Name Reset
  kind: action
  params:
    - name: terminal
      type: integer

- id: get_parameter
  label: Get Parameter (VCP)
  kind: query
  params:
    - name: op_code_page
      type: integer
    - name: op_code
      type: integer

- id: set_parameter
  label: Set Parameter (VCP)
  kind: action
  params:
    - name: op_code_page
      type: integer
    - name: op_code
      type: integer
    - name: value
      type: integer

Feedbacks

- id: get_parameter_reply
  type: object
  properties:
    result: enum[no_error, unsupported]
    op_code_page: integer
    op_code: integer
    type: enum[set_parameter, momentary]
    max_value: integer
    current_value: integer

- id: set_parameter_reply
  type: object
  properties:
    result: enum[no_error, unsupported]
    op_code_page: integer
    op_code: integer
    type: enum[set_parameter, momentary]
    max_value: integer
    requested_value: integer

- id: command_reply
  type: object
  properties:
    result: enum[no_error, unsupported]
    data: string

Variables

- id: backlight
  label: Backlight
  type: integer
  range: [0, 100]
  access: read_write

- id: temperature_sensor
  label: Temperature Sensor
  type: integer
  access: read

Events

- id: null_message
  label: NULL Message
  description: Returned on timeout error, unsupported message, BCC error, or when monitor is busy

Macros

# No explicit multi-step macros documented

Safety

confirmation_required_for: []
interlocks: []

Notes

Communication packet interval must exceed 600msec. Monitor disconnects TCP connection after 15 minutes of inactivity. Command format: SOH + Reserved + Destination + Source + MessageType + MessageLength + STX + Data + ETX + BCC + CR. Destination address mapping uses Monitor ID table (1=A, 2=B, ..., 26=Z, then hex). Group broadcast uses '*' (2Ah).

Provenance

source_domains:
  - sharp-displays.jp.sharp
source_urls:
  - https://sharp-displays.jp.sharp/support/webdl/dl_service/data/display/manual/e658/eu/External_Control_Exx8_Series_EN_Rev1.0.pdf
retrieved_at: 2026-05-26T01:19:38.897Z
last_checked_at: 2026-05-31T21:05:29.255Z

Verification Summary

verdict: verified
checked_at: 2026-05-31T21:05:29.255Z
matched_actions: 16
action_count: 16
confidence: medium
summary: "All 16 spec actions map one-to-one to documented CTL and VCP message-type operations in the source; transport values confirmed verbatim. (6 unresolved item(s) noted in Known Gaps.)"

Known Gaps

- "LAN port stated as 7142; RS-232C port not stated (uses standard D-Sub 9-pin)"
- "specific VCP opcode table not included in source (referenced as chapter 8)"
- "detailed CTL command parameter structures not fully specified in excerpt"
- "firmware version compatibility not stated"
- "voltage/current/power specifications not stated"
- "error recovery sequences not documented"