Summary
Sharp LC-32SV40U, LC-42SV50U, LC-46SV50U LCD TVs with RS-232C serial control. Eight-ASCII-character commands with CR terminator. Covers power, input selection, volume, AV mode, position, view mode, mute, surround, audio selection, sleep timer, channel tuning, and closed caption.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: unknown # UNRESOLVED: authentication requirements are not specified
Traits
traits:
- powerable # power on/off commands
- queryable # "?" parameter returns current setting
- levelable # volume 0-100
- routable # input selection commands
Actions
actions:
- id: power_on_setting
label: Power On Command Setting
kind: action
params:
- name: accept
type: integer
description: "0: reject power on command (Off), 1: accept power on command (On)"
command: "RSPW"
notes: "Parameter is accept followed by three spaces (0 = reject, 1 = accept); append CR. Underscore in the source means a space."
- id: power_off
label: Power Off
kind: action
params: []
command: "POWR"
notes: "Parameter is 0 followed by three spaces; append CR. Shifts TV to standby."
- id: power_on
label: Power On
kind: action
params: []
command: "POWR"
notes: "Parameter is 1 followed by three spaces; append CR. Wait until system is completely powered off (LED turns Red) before sending."
- id: input_toggle
label: Input Selection Toggle
kind: action
params: []
command: "ITGD"
notes: "Parameter x is any numerical value; complete the four-character parameter with spaces. Append CR."
- id: input_tv
label: Input TV
kind: action
params: []
command: "ITVD"
notes: "Parameter 0, with spaces for the remainder of the four-character parameter. Append CR. Switches to TV input; channel remains as last memory."
- id: input_av
label: Input AV (INPUT1-6)
kind: action
params:
- name: input_number
type: integer
description: "Input terminal number (1-6)"
command: "IAVD"
- id: av_mode
label: AV Mode Selection
kind: action
params:
- name: mode
type: integer
description: "0: Toggle, 1: Standard, 2: Movie, 3: Game, 4: PC, 5: Dynamic, 6: Dynamic (Fixed), 7: User"
command: "AVMD"
- id: volume
label: Volume
kind: action
params:
- name: level
type: integer
description: "Volume level (0-100)"
command: "VOLM"
- id: h_position
label: H-Position
kind: action
params:
- name: position
type: integer
description: "Horizontal position (0-100). PC mode only."
command: "HPOS"
notes: "Menu display range +/-50. Only PC mode."
- id: v_position
label: V-Position
kind: action
params:
- name: position
type: integer
description: "Vertical position (0-40). PC mode only."
command: "VPOS"
notes: "Menu display range +/-20. Only PC mode."
- id: clock
label: Clock
kind: action
params:
- name: value
type: integer
description: "Clock adjustment (0-180). PC mode only."
command: "CLCK"
notes: "Menu display range +/-90. Only PC mode."
- id: phase
label: Phase
kind: action
params:
- name: value
type: integer
description: "Phase adjustment (0-40). PC mode only."
command: "PHSE"
notes: "Menu display range +/-20. Only PC mode."
- id: view_mode
label: View Mode
kind: action
params:
- name: mode
type: integer
description: "0: Toggle, 1: Normal, 2: S.Stretch, 3: Stretch, 4: Zoom, 5: Full Screen, 6: Dot by Dot, 7: Cinema"
command: "WIDE"
notes: "Available modes depend on signal type and input."
- id: mute
label: Mute
kind: action
params:
- name: state
type: integer
description: "0: Toggle, 1: On, 2: Off"
command: "MUTE"
- id: surround
label: Surround
kind: action
params:
- name: state
type: integer
description: "0: Toggle, 1: On, 2: Off"
command: "ACSU"
- id: audio_selection
label: Audio Selection
kind: action
params: []
command: "ACHA"
notes: "Parameter x is any numerical value; complete the four-character parameter with spaces. Append CR. Toggle operation."
- id: sleep_timer
label: Sleep Timer
kind: action
params:
- name: timer
type: integer
description: "0: Off, 1: 30 min, 2: 60 min, 3: 90 min, 4: 120 min"
command: "OFTM"
- id: channel_direct_analog
label: Channel Direct (Analog)
kind: action
params:
- name: channel
type: integer
description: "Analog channel number (1-135). Air: 2-69, Cable: 1-135."
command: "DCCH"
notes: "Input change included if not in TV display."
- id: channel_digital_air
label: Channel Digital Air (Two-Part)
kind: action
params:
- name: channel
type: integer
description: "Digital Air channel (0100-9999). Two-part number: 2-digit + 2-digit."
command: "DA2P"
notes: "The source specifies two two-digit parts occupying all four parameter positions (0100-9999); retain required leading zeroes, for example 0100, rather than replacing them with trailing spaces."
- id: channel_digital_cable_major
label: Channel Digital Cable Major
kind: action
params:
- name: major
type: integer
description: "Front half of digital cable channel (1-999); source parameter pattern is three value positions followed by one space."
command: "DC2U"
- id: channel_digital_cable_minor
label: Channel Digital Cable Minor
kind: action
params:
- name: minor
type: integer
description: "Rear half of digital cable channel (0-999); source parameter pattern is three value positions followed by one space."
command: "DC2L"
- id: channel_digital_cable_onepart_low
label: Channel Digital Cable One-Part (<10000)
kind: action
params:
- name: channel
type: integer
description: "Digital cable one-part channel (0-9999)."
command: "DC10"
- id: channel_digital_cable_onepart_high
label: Channel Digital Cable One-Part (High Range)
kind: action
params:
- name: channel
type: integer
description: "Raw parameter range 0-6383. The source describes this as digital cable one-part numbers more than 10000; logical channel-to-parameter mapping and boundary behavior are UNRESOLVED."
command: "DC11"
- id: channel_up
label: Channel Up
kind: action
params: []
command: "CHUP"
notes: "Parameter x is any numerical value; complete the four-character parameter with spaces. Append CR."
- id: channel_down
label: Channel Down
kind: action
params: []
command: "CHDW"
notes: "Parameter x is any numerical value; complete the four-character parameter with spaces. Append CR. If not in TV display, switches to TV input."
- id: closed_caption
label: Closed Caption Toggle
kind: action
params: []
command: "CLCP"
notes: "Parameter x is any numerical value; complete the four-character parameter with spaces. Append CR. Toggle operation."
Feedbacks
feedbacks:
- id: power_state
type: enum
description: "Power-state response placeholder; UNRESOLVED: source does not identify which commands accept queries or specify power response values."
- id: volume_level
type: integer
description: "Volume response placeholder; UNRESOLVED: source does not establish VOLM query support or response encoding. The settable volume range is 0-100."
- id: input_state
type: enum
description: "Input-state response placeholder; UNRESOLVED: source does not identify a query-capable input command or response encoding."
- id: mute_state
type: enum
description: "Mute-state response placeholder; UNRESOLVED: source does not establish MUTE query support or response encoding."
- id: av_mode_state
type: integer
description: "AV-mode response placeholder; UNRESOLVED: source does not establish AVMD query support or response encoding."
- id: response_ok
type: enum
values: [OK, ERR]
description: "OK returned on success, ERR on communication error or incorrect command."
Variables
# UNRESOLVED: no distinct settable variables beyond actions - parameter ranges documented inline
Events
# UNRESOLVED: no unsolicited notifications documented in source
Macros
# UNRESOLVED: no multi-step sequences documented in source
Safety
confirmation_required_for: []
interlocks:
- "Power On command must wait until system is completely powered off (LED indicator turns Red)"
- "Do not send multiple commands simultaneously - wait for OK response before next command"
# UNRESOLVED: no additional safety/interlock procedures documented
Notes
- Each
commandfield contains the four-character mnemonic reconstructed from the source table columns. It is not a complete request. Send that mnemonic followed by the four-character parameter and CR (0DH): C1 C2 C3 C4 P1 P2 P3 P4. - Enter the parameter value within its documented range and format, preserving required digits (including the four-digit DA2P format); fill any remaining parameter positions with spaces. Do not prepend the invented
000padding from the earlier spec. Explicit underscores in the source require spaces. The source does not establish every formatting detail for every numeric width; test against the device before relying on ambiguous cases. - Underscore (_) in parameter column means enter a space character
- Asterisk (*) means enter a value in the range indicated
- "x" can be replaced by any numerical value
- ERR returns when parameter is outside adjustable range
- Sending "?" as a parameter queries the current setting for some commands; the source does not identify which commands support queries or unambiguously show the query padding.
- RS-232C terminal: 9-pin D-sub male connector on all models
- Commands not listed in the table are not guaranteed to operate
Provenance
source_domains:
- files.sharpusa.com
- assets.sharpnecdisplays.us
- github.com
- manualslib.com
source_urls:
- http://files.sharpusa.com/Downloads/ForHome/HomeEntertainment/LCDTVs/Manuals/tel_man_LC32SV40U_LC42SV50U_LC46SV50U.pdf
- https://assets.sharpnecdisplays.us/documents/miscellaneous/pj-control-command-codes.pdf
- https://github.com/golliher/go-sharptv
- https://github.com/jdwhite/aquosctl
- https://www.manualslib.com/brand/sharp/
retrieved_at: 2026-05-15T02:35:06.944Z
last_checked_at: 2026-09-28T14:21:57.780Z
Verification Summary
verdict: verified
checked_at: 2026-09-28T14:21:57.780Z
matched_actions: 26
action_count: 26
confidence: medium
summary: "All 26 table-backed actions match; documented framing is retained and unspecified query/channel encodings remain explicit gaps. (16 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "no TCP/IP or other transport documented — serial only"
- "no response timeout specified"
- "no maximum command rate specified — source says wait for OK before next command"
- "authentication requirements are not specified"
- "source does not identify which commands accept queries or specify power response values.\""
- "source does not establish VOLM query support or response encoding. The settable volume range is 0-100.\""
- "source does not identify a query-capable input command or response encoding.\""
- "source does not establish MUTE query support or response encoding.\""
- "source does not establish AVMD query support or response encoding.\""
- "no distinct settable variables beyond actions - parameter ranges documented inline"
- "no unsolicited notifications documented in source"
- "no multi-step sequences documented in source"
- "no additional safety/interlock procedures documented"
- "exact command byte encoding for all parameter positions not fully clear from OCR"
- "response timeout not specified"
- "maximum serial command rate not specified"
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0