Summary
Sharp PN-E series LCD monitor (covers PN-E869/E759/E659/E559/E509/E439/E329) controlled via RS-232C or LAN (TCP). Uses S-Format commands: a 4-character command field plus 4-character parameter field, terminated by return code (0DH 0AH). Power, input, picture, system, tile-matrix, audio, and telemetry query commands are documented.
Transport
protocols:
- serial
- tcp
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
addressing:
port: 10008 # LAN data port stated for TCP control
auth:
type: basic # username + password required over LAN; default username/password is "ADMIN", must be changed
# UNRESOLVED: token/credential format beyond username+password not described
Traits
traits:
- powerable # inferred from POWR power on/off commands
- routable # inferred from INPS input-mode selection
- queryable # inferred from R-direction query commands (POWR?, VOLM?, DSTA, ERRT, PXCK, INF1, SRNO)
- levelable # inferred from level-set commands (VLMP, CRTR, CRTG, CRTB, VOLM, MINT)
Actions
# S-Format command: 4-char command + 4-char parameter, terminated by return code (0DH 0AH or 0DH).
# Parameter field MUST be 4 characters, padded with spaces. e.g. "VOLM 30", not "VOLM30". EXCEPTION: DATE takes a 10-character parameter AABBCCDDEE (see set_date_time).
# Commands marked "●" usable in standby; "○" usable in input-signal-wait or power-on; "-" power-on only.
# Commands POWR/INPS/BOMD/WIDE return "WAIT" while executing; do not send other commands until value returned.
- id: power_standby
label: Power Standby
kind: action
command: "POWR0000"
params: []
notes: "Switches monitor to standby state. ● usable in standby."
- id: power_on
label: Power On
kind: action
command: "POWR0001"
params: []
notes: "Returns from standby state. After power Off, wait >= 10s before next command."
- id: power_query
label: Power State Query
kind: query
command: "POWR????"
params: []
notes: "Reply 0=Standby, 1=Normal mode, 2=Input signal waiting state."
- id: input_select_toggle
label: Input Mode Toggle
kind: action
command: "INPS0000"
params: []
notes: "Toggle change for input mode. ○ usable in waiting/power-on."
- id: input_select_hdmi1
label: Select Input HDMI1
kind: action
command: "INPS0010"
params: []
- id: input_select_media_player
label: Select Input Media Player
kind: action
command: "INPS0011"
params: []
- id: input_select_hdmi2
label: Select Input HDMI2
kind: action
command: "INPS0013"
params: []
- id: input_select_usb_c
label: Select Input USB-C
kind: action
command: "INPS0027"
params: []
- id: picture_mode_standard
label: Picture Mode Standard
kind: action
command: "BMOD0000"
params: []
- id: picture_mode_high_bright
label: Picture Mode High Bright
kind: action
command: "BMOD0004"
params: []
- id: picture_mode_custom
label: Picture Mode Custom
kind: action
command: "BMOD0008"
params: []
- id: picture_mode_retail
label: Picture Mode Retail
kind: action
command: "BMOD0022"
params: []
- id: picture_mode_conferencing
label: Picture Mode Conferencing
kind: action
command: "BMOD0023"
params: []
- id: picture_mode_transportation
label: Picture Mode Transportation
kind: action
command: "BMOD0025"
params: []
- id: backlight_set
label: Set Backlight
kind: action
command: "VLMP{level:04d}"
params:
- name: level
type: integer
range: [0, 100]
description: "Backlight level 0-100, 4-char zero-padded."
notes: "Direction WR; readable via VLMP????"
- id: aspect_wide
label: Aspect Wide
kind: action
command: "WIDE0001"
params: []
- id: aspect_normal
label: Aspect Normal
kind: action
command: "WIDE0002"
params: []
- id: aspect_1to1
label: Aspect 1:1
kind: action
command: "WIDE0003"
params: []
- id: aspect_full
label: Aspect Full
kind: action
command: "WIDE0011"
params: []
- id: color_temp_thru
label: Color Temperature THRU
kind: action
command: "CTMP0000"
params: []
- id: color_temp_warm
label: Color Temperature Warm
kind: action
command: "CTMP0008"
params: []
- id: color_temp_normal
label: Color Temperature Normal
kind: action
command: "CTMP0013"
params: []
- id: color_temp_cool
label: Color Temperature Cool
kind: action
command: "CTMP0022"
params: []
- id: color_temp_custom
label: Color Temperature Custom
kind: action
command: "CTMP0099"
params: []
- id: r_gain_set
label: Set R Gain
kind: action
command: "CRTR{value:04d}"
params:
- name: value
type: integer
range: [0, 255]
description: "R gain value when COLOR TEMPERATURE = CUSTOM. Error if CTMP != CUSTOM."
- id: g_gain_set
label: Set G Gain
kind: action
command: "CRTG{value:04d}"
params:
- name: value
type: integer
range: [0, 255]
description: "G gain value when COLOR TEMPERATURE = CUSTOM."
- id: b_gain_set
label: Set B Gain
kind: action
command: "CRTB{value:04d}"
params:
- name: value
type: integer
range: [0, 255]
description: "B gain value when COLOR TEMPERATURE = CUSTOM."
- id: set_date_time
label: Set Date and Time
kind: action
command: "DATE{AABBCCDDEE}"
params:
- name: AA
type: integer
description: "Year"
- name: BB
type: integer
description: "Month"
- name: CC
type: integer
description: "Day"
- name: DD
type: integer
description: "Hour"
- name: EE
type: integer
description: "Minute"
notes: "Direction WR; parameter field is 10 characters AABBCCDDEE (exception to the 4-character parameter rule); AA=Year, BB=Month, CC=Day, DD=Hour, EE=Minute. Power-on only."
- id: thermal_sensor_orientation
label: Thermal Sensor Setting
kind: action
command: "STDR{value:04d}"
params:
- name: value
type: integer
range: [0, 1]
description: "0=LANDSCAPE, 1=PORTRAIT"
- id: model_info_query
label: Model Info Query
kind: query
command: "INF1????"
params: []
notes: "● Returns model name."
- id: serial_no_query
label: Serial Number Query
kind: query
command: "SRNO????"
params: []
notes: "Returns serial number."
- id: key_lock
label: Key Lock Setting
kind: action
command: "ALCM{value:04d}"
params:
- name: value
type: integer
range: [0, 1]
description: "0=UNLOCKED, 1=LOCK ALL"
- id: ir_lock
label: IR Lock Setting
kind: action
command: "ALCR{value:04d}"
params:
- name: value
type: integer
range: [0, 3]
description: "0=UNLOCKED, 1=LOCK ALL, 2=LOCK EXCEPT VOLUME, 3=LOCK EXCEPT POWER"
- id: motion_set
label: Motion Setting
kind: action
command: "SCSV{value:04d}"
params:
- name: value
type: integer
range: [0, 1]
description: "0=OFF, 1=ON"
- id: motion_interval_set
label: Motion Interval
kind: action
command: "MINT{value:04d}"
params:
- name: value
type: integer
range: [10, 600]
description: "Valid values are multiples of 10 (10..600)."
- id: refresh_mode_set
label: Refresh Mode
kind: action
command: "PREF{value:04d}"
params:
- name: value
type: integer
range: [0, 2]
description: "0=OFF, 1=MODE1, 2=MODE2"
- id: tile_matrix_enable
label: Tile Matrix Enable
kind: action
command: "ENLG{value:04d}"
params:
- name: value
type: integer
range: [0, 1]
description: "0=OFF, 1=ON"
- id: tile_matrix_mode_set
label: Tile Matrix Mode
kind: action
command: "EMHV{value:04d}"
params:
- name: value
type: integer
enum: [12, 13, 22, 21, 31]
description: "m x n expressed as mn; m,n = longest, shortest monitor counts."
- id: tile_position_set
label: Tile Matrix Position
kind: action
command: "EPOS{value:04d}"
params:
- name: value
type: integer
range: [1, 4]
- id: tile_mode_position_set
label: Tile Matrix Mode and Position
kind: action
command: "ESPG{XXYY}"
params:
- name: XX
type: integer
description: "ENLARGE MODE (same values as EMHV)"
- name: YY
type: integer
description: "SCREEN POSITION (same values as EPOS, 1-4)"
- id: bezel_adjust_set
label: Bezel Adjust
kind: action
command: "BZCO{value:04d}"
params:
- name: value
type: integer
range: [0, 1]
description: "0=OFF, 1=ON"
- id: volume_set
label: Set Volume
kind: action
command: "VOLM{level:04d}"
params:
- name: level
type: integer
range: [0, 100]
description: "Volume level 0-100, 4-char zero-padded. Example: VOLM0030 = VOL 30."
- id: mute_set
label: Mute Audio
kind: action
command: "MUTE{value:04d}"
params:
- name: value
type: integer
range: [0, 1]
description: "0=OFF, 1=ON"
- id: temperature_state_query
label: Temperature Sensor State Query
kind: query
command: "DSTA????"
params: []
notes: "Reply: 0=normal, 1=abnormal+standby, 2=abnormal (clear by turning off main power), 3=abnormal+backlight dimmed, 4=sensor abnormal."
- id: temperature_value_query
label: Temperature Acquisition Query
kind: query
command: "ERRT????"
params: []
notes: "Returns temperature at sensor. 126 indicates sensor abnormality."
- id: resolution_query
label: Resolution Query
kind: query
command: "PXCK????"
params: []
notes: "Returns current resolution in form hhh, vvv."
- id: lan_disconnect
label: LAN Disconnect (BYE)
kind: action
command: "BYE\\r"
params: []
notes: "LAN-only. Response 'Goodbye' then connection is closed."
Feedbacks
- id: power_state
type: enum
values: [standby, normal, input_signal_waiting]
query_command: "POWR????"
notes: "From POWR? reply: 0/1/2."
- id: ok_ack
type: literal
values: ["OK"]
notes: "Returned when a command is executed correctly. Terminated by 0DH 0AH."
- id: err_ack
type: literal
values: ["ERR"]
notes: "Returned when command not recognized or cannot be used in current state."
- id: wait_ack
type: literal
values: ["WAIT"]
notes: "Returned for POWR, INPS, BOMD, WIDE while executing. Wait for value; do not send other commands."
- id: temperature_state
type: enum
values: [normal, abnormal_standby, abnormal, abnormal_dimmed, sensor_abnormal]
query_command: "DSTA????"
notes: "From DSTA reply: 0/1/2/3/4."
Variables
- id: backlight_level
type: integer
range: [0, 100]
read_command: "VLMP????"
write_command: "VLMP{level:04d}"
- id: volume_level
type: integer
range: [0, 100]
read_command: "VOLM????"
write_command: "VOLM{level:04d}"
- id: r_gain
type: integer
range: [0, 255]
read_command: "CRTR????"
write_command: "CRTR{value:04d}"
- id: g_gain
type: integer
range: [0, 255]
read_command: "CRTG????"
write_command: "CRTG{value:04d}"
- id: b_gain
type: integer
range: [0, 255]
read_command: "CRTB????"
write_command: "CRTB{value:04d}"
- id: motion_interval
type: integer
range: [10, 600]
read_command: "MINT????"
write_command: "MINT{value:04d}"
- id: temperature_value
type: integer
read_command: "ERRT????"
notes: "126 indicates sensor abnormality."
- id: model_name
type: string
read_command: "INF1????"
- id: serial_number
type: string
read_command: "SRNO????"
- id: current_resolution
type: string
read_command: "PXCK????"
notes: "Returns hhh, vvv form."
Events
# UNRESOLVED: source describes no unsolicited notifications. Responses are synchronous to commands.
Macros
# LAN login sequence (3-step, documented in source):
# 1. Connect TCP to monitor IP:10008 -> monitor sends "Login: "
# 2. Send "<username>\r" -> monitor sends "Password: "
# 3. Send "<password>\r" -> monitor sends "OK\r"
# Default username and password is "ADMIN"; source requires they be changed when PC CONTROL is on.
# Disconnect: send "BYE\r" -> monitor sends "Goodbye\r" and closes connection.
# Auto-logout after configured idle period.
Safety
confirmation_required_for: []
interlocks:
- id: power_off_cooldown
description: "After a power Off command, wait at least 10 seconds before sending the next command."
source: "Communication interval TIPS section."
- id: command_interval
description: "Provide >= 100 ms between command response and the next command transmission."
source: "Communication interval section."
- id: wait_state_holdoff
description: "When 'WAIT' is returned (POWR, INPS, BOMD, WIDE), do not send any command until the value is returned."
source: "Response code format section."
- id: temperature_standby
description: "Temperature abnormality may force standby state or dim backlight; clearing state 2 requires turning off main power."
source: "DSTA reply semantics."
# UNRESOLVED: full interlock / power-on sequencing procedures for installation not in refined excerpt.
Notes
- S-Format command = 4-character command field + 4-character parameter field + return code (0DH 0AH or 0DH). Parameter MUST be exactly 4 characters, space-padded, except DATE, whose parameter is the 10-character string AABBCCDDEE. Example:
VOLM 30(with the 4-char parameter being " 30") — the source shows "VOLM0030" but alsoVOLM 30/VOLM ? ? ? ?notation indicating space padding within the 4-char parameter field. - "R" direction commands accept
?(or????) in the parameter field to read the current value. - After OK/ERR, set a command-response timeout of >= 10 seconds.
- If no communication is established (bad cable/connection), nothing is returned — not even ERR. Application must handle silence as a transport error and resend.
- "ERR" may also be returned when interference corrupts a command; resend on ERR.
- LAN mode: requires "PC CONTROL" set to ON in CONTROL SETTINGS (SYSTEM menu). When PC CONTROL is on, default username/password ADMIN must be changed.
- LAN commands are identical to RS-232C commands; only the transport and login wrapping differ.
- "●" = usable in standby, input-signal-waiting, or power-on. "○" = usable in input-signal-waiting or power-on. "-" = power-on only.
Provenance
source_domains:
- business.sharpusa.com
source_urls:
- https://business.sharpusa.com/portals/0/downloads/manuals/pn-exx9_s-format_command_manual_english.pdf
- https://business.sharpusa.com/portals/0/downloads/manuals/pne869-e759-e659-e559-e509-e439-e329_operation-manual.pdf
retrieved_at: 2026-08-03T12:08:53.676Z
last_checked_at: 2026-10-01T06:45:26.235Z
Verification Summary
verdict: verified
checked_at: 2026-10-01T06:45:26.235Z
matched_actions: 49
action_count: 49
confidence: medium
summary: "All 49 action units map to documented S-Format commands; transport (9600 8N1, port 10008, login) is supported and every source command is represented. (9 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "firmware version compatibility not stated in source. Voltage/current/power specs not in refined excerpt."
- "token/credential format beyond username+password not described"
- "source describes no unsolicited notifications. Responses are synchronous to commands."
- "full interlock / power-on sequencing procedures for installation not in refined excerpt."
- "firmware version compatibility not stated."
- "full command set outside S-Format (e.g. any other \"Command Format\" modes) not in refined excerpt."
- "response timeout upper bound beyond \">= 10 s\" not stated."
- "voltage / current / power specifications not present in refined excerpt."
- "auth credential format constraints (length, charset) for LAN login not described beyond default \"ADMIN\"."