Summary
TCP/RS-232 interface for Rako wireless lighting control. Supports House/Room/Channel addressing with scenes, dimming via LEVEL, and feedback output. Serial at 9600/8/N/1; TCP on port 9761.
Transport
protocols:
- tcp
- serial
addressing:
port: 9761 # TCP port stated in source
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none # Xon/Xoff or None stated
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # OFF and LEVEL commands present
- routable # ROOM, CHANNEL, SCENE commands present
- queryable # STATUS and VER commands present
Actions
- id: house_set
label: Set House Address
kind: action
params:
- name: house_number
type: integer
description: House number 1-255
notes: Stored in non-volatile memory. Deprecated in favor of web UI.
- id: room_set
label: Set Room Address
kind: action
params:
- name: room_number
type: integer
description: Room 0-255. 0 = all rooms in house. Omit to set 0.
notes: Stored in non-volatile memory.
- id: channel_set
label: Set Channel Address
kind: action
params:
- name: channel_number
type: integer
description: Channel 0-15. 0 = all channels in room. Omit to set 0.
- id: scene_set
label: Set Scene
kind: action
params:
- name: scene_number
type: integer
description: Scene 1-16 (corresponds to control panel buttons)
- id: power_off
label: Power Off
kind: action
params: []
- id: level_set
label: Set Power Level
kind: action
params:
- name: power_level
type: integer
description: Level 0-255 (255 = 100%)
- id: store
label: Store Current Level to Scene
kind: action
params: []
- id: command_send
label: Send Raw Command Number
kind: action
params:
- name: command_number
type: integer
description: Command 0-15 per Command Number Summary
- id: eeprom_write
label: Write EEPROM Address
kind: action
params:
- name: address
type: integer
description: EEPROM address
- name: data
type: integer
description: Data value
- id: address_set
label: Set EEPROM Target Address
kind: action
params:
- name: address
type: integer
description: EEPROM address 0-127
- id: data_set
label: Set EEPROM Data Value
kind: action
params:
- name: data
type: integer
description: Data byte value
Feedbacks
- id: command_feedback
label: Command Feedback Output
type: string
format: "<RRR:CCC:II" | "<RRR:CCC:III:DDD"
description: |
RRR = room 0-255 (3 digits)
CC/CCC = channel 0-15 (2-3 digits, 0 = all)
II = 2-digit instruction (Table 2) for commands 0-15
III = 3-digit instruction (Table 4) for commands >=16
DDD = data value for extra instructions
example: "<004:00:03" (Room 4, Channel 0, Scene 1)
- id: ok_response
label: Valid Command Acknowledgement
type: string
values:
- OK
- id: invalid_command_response
label: Invalid Command Response
type: string
values:
- Invalid Command!
- id: prompt
label: Command Prompt
type: string
description: ">" issued when interface ready for command
- id: version_info
label: Version Information
type: string
description: Returned by VER command
- id: status_info
label: Status Information
type: string
description: "HO:nnn RO:nnn CH:nnn EH:nnn format from STATUS command"
Variables
- id: house_address
label: House Address
type: integer
range: [1, 255]
default: 0
storage: eeprom
- id: room_address
label: Room Address
type: integer
range: [0, 255]
default: 0
storage: eeprom
- id: channel_address
label: Channel Address
type: integer
range: [0, 15]
default: 0
storage: eeprom
- id: eeprom_scene_1
label: Scene 1 Preset Value
type: integer
range: [0, 255]
address: 1
- id: eeprom_scene_2
label: Scene 2 Preset Value
type: integer
range: [0, 255]
address: 2
- id: eeprom_scene_3
label: Scene 3 Preset Value
type: integer
range: [0, 255]
address: 3
- id: eeprom_scene_4
label: Scene 4 Preset Value
type: integer
range: [0, 255]
address: 4
- id: eeprom_start_mode
label: Start Mode After Power Failure
type: integer
range: [0, 255]
address: 9
description: "0=off, 1-4=scene, 5=memory, 6-255=absolute power level"
- id: eeprom_scene_fade_rate
label: Scene Fade Rate
type: integer
range: [0, 255]
address: 34
description: "0=fast"
- id: eeprom_scene_fade_decay_rate
label: Scene Fade Decay Rate
type: integer
range: [0, 255]
address: 36
description: "0=no decay"
Events
# Device does not initiate unsolicited events. All output is response to commands.
# UNRESOLVED: whether battery low notifications (instruction 10) are sent asynchronously from battery-powered devices
Macros
# No explicit multi-step macros documented.
# UNRESOLVED: RASOFT software-defined profiles (EEPROM 63-127) not documented as macro sequences
Safety
confirmation_required_for:
- eeprom_write # Warning: writing address 0 affects all dimmers with same house
interlocks: []
# UNRESOLVED: power sequencing requirements not stated in source
Notes
Command format: [COMMAND] <VALUE>\r. Delimiters: whitespace, tabs, or colons. Case insensitive. Shortened non-ambiguous versions allowed (e.g., ROOM:1 → RO:1).
Prompt character ">" indicates interface ready. Characters echoed. Responses: "OK" (valid) or "Invalid Command!" (invalid).
TCP connection on port 9761. Serial 9600/8/N/1. Hardware flow control via CTS line; if unused, observe ">" prompt before sending next command to avoid buffer overflow.
Provenance
source_domains:
- rakocontrols.com
source_urls:
- https://rakocontrols.com/media/1512/rako-rs232-command-summary.pdf
- https://rakocontrols.com/media/2065/accessing-the-rako-hub.pdf
- https://rakocontrols.com/media/1956/accessing-the-rako-bridge-v222.pdf
- https://rakocontrols.com/integration/system-integration/
retrieved_at: 2026-05-22T17:22:30.713Z
last_checked_at: 2026-05-31T07:07:38.318Z
Verification Summary
verdict: verified
checked_at: 2026-05-31T07:07:38.318Z
matched_actions: 11
action_count: 11
confidence: medium
summary: "All 11 spec actions matched verbatim to source commands; transport parameters (9600 baud, 8/N/1, port 9761) verified; complete protocol coverage. (7 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "Rako dimmer/wireless device models supported not enumerated in source"
- "whether battery low notifications (instruction 10) are sent asynchronously from battery-powered devices"
- "RASOFT software-defined profiles (EEPROM 63-127) not documented as macro sequences"
- "power sequencing requirements not stated in source"
- "COMMAND instructions 9, 11, 14 table entries empty in source"
- "ps1-ps4 instructions (3-6) not fully documented, SCENE recommended instead"
- "full RASOFT profile data format (EEPROM 63-127) not documented"