Summary

QSC DPM (Digital Preset Manager) cinema audio processor platform. Supports RS-232, Ethernet (TCP/UDP), SNMP, and contact closure (GPI) control. TCP port 4446, UDP port 4448. Serial default 115200 baud. DCM models support only serial and Ethernet (no GPI). Preset, volume and mute control are not applicable for DCM models.

Transport

protocols:
  - serial
  - tcp
  - udp
  - snmp
serial:
  baud_rate: 115200  # default; selectable: 57600, 38400, 19200, 9600, 1200, 300
  data_bits: 8
  parity: none
  stop_bits: 1
  flow_control: none
addressing:
  port: 4446  # TCP
  udp_port: 4448  # UDP
auth:
  type: UNRESOLVED  # source does not state authentication requirements

Traits

- powerable  # dpm100ampson / dpm100ampsoff
- routable  # preset selection commands
- queryable  # status query commands (version, serial, preset name, mute state, fader level)
- levelable  # dpm100fader with incremental and absolute modes

Actions

- id: preset_change
  label: Preset Change
  kind: action
  params:
    - name: preset
      type: integer
      description: Preset number 1-32 (1-16 audio, 17-32 control)

- id: preset_name_query
  label: Preset Name Query
  kind: action
  params:
    - name: preset
      type: integer
      description: Preset number 1-32

- id: mute
  label: Mute
  kind: action
  params:
    - name: state
      type: integer
      description: 1 = mute on, 0 = mute off

- id: fader_set
  label: Set Master Fader
  kind: action
  params:
    - name: value
      type: number
      description: Volume in dB (-90.0 to 10.0, .1dB increments)

- id: fader_inc
  label: Increment Fader
  kind: action
  params:
    - name: amount
      type: number
      description: Increment amount in dB (use ++ prefix for positive, -- prefix for negative)
    - name: direction
      type: string
      description: "+" or "-" for fixed .5dB step

- id: amps_on
  label: Amps On
  kind: action
  description: Powers on all amplifiers connected via DataPort cables

- id: amps_off
  label: Amps Off
  kind: action
  description: Puts all amplifiers in standby

- id: version_query
  label: Firmware Version Query
  kind: action

- id: serial_number_query
  label: Serial Number Query
  kind: action

- id: device_name_query
  label: Device Name Query
  kind: action

- id: help
  label: Command Help
  kind: action

- id: tcp_query
  label: TCP Status Query
  kind: action
  description: Sends GET over TCP after a set/query command to retrieve the device response (TCP only)

Feedbacks

- id: preset_response
  type: string
  description: Returns "Audio Preset = X" on query, error on invalid

- id: preset_name_response
  type: string
  description: Returns "Preset Name = X"

- id: mute_response
  type: integer
  values: [0, 1]
  description: Returns Mute state

- id: fader_response
  type: number
  description: Returns "Master Fader = X" in dB

- id: version_response
  type: string
  description: Returns firmware version as "major.minor.build"

- id: serial_response
  type: string
  description: Returns device serial number

- id: device_name_response
  type: string
  description: Returns device name

- id: error_response
  type: string
  description: Returns "'command' is an invalid command" on bad input

Variables

# UNRESOLVED: SNMP variables not enumerated in source - MIB file exported from DPM Manager

Events

# UNRESOLVED: device does not send unsolicited notifications per source - all queries are explicit

Macros

# UNRESOLVED: no multi-step macros described in source

Safety

confirmation_required_for: []
interlocks:
  - Fire Alarm Mute must be cleared (automation input inactive) before normal operation resumes
  - Priority preset recall cannot be overridden until trigger level inactive
# UNRESOLVED: no voltage/current/power specs in source

Notes

DPM 100/100H/300/300H include GPI inputs (6 contact closure inputs). DCM 100/300 do not support GPI or preset/volume/mute control. TCP connections closed by device after each command — must reopen before each command. Minimum 400ms between Ethernet commands for optimal performance. Serial commands terminated by newline (\n or \r\n). DCP300 backward-compatible command set supported (same syntax, query-only responses). Authentication requirements are UNRESOLVED — source does not state whether authentication is required for serial, Ethernet, or SNMP access.

Provenance

source_domains:
  - help.qsys.com
source_urls:
  - https://help.qsys.com/Content/External_Control_APIs/QRC/QRC_Overview.htm
  - https://help.qsys.com/Content/External_Control_APIs/QRC/QRC_Commands.htm
  - https://help.qsys.com/Content/External_Control_APIs/ECP/ECP_Overview.htm
retrieved_at: 2026-04-30T03:11:42.670Z
last_checked_at: 2026-09-30T00:04:59.423Z

Verification Summary

verdict: verified
checked_at: 2026-09-30T00:04:59.423Z
matched_actions: 12
action_count: 12
confidence: medium
summary: "All 12 actions match the 11 command mnemonics and documented transport; fader actions share a mnemonic, and DCP300 spellings are aliases. (7 unresolved item(s) noted in Known Gaps.)"

Known Gaps

- "GPI configuration parameters not fully detailed in source — only described functionally, no pin assignments or voltage specs given"
- "SNMP variables not enumerated in source - MIB file exported from DPM Manager"
- "device does not send unsolicited notifications per source - all queries are explicit"
- "no multi-step macros described in source"
- "no voltage/current/power specs in source"
- "SNMP MIB not included in source, must be exported from DPM Manager"
- "GPI pinout details not in source, referenced to DPM User's Manual"