Summary
Philips Institutional Television (ITV) with NET1CCI card, controlled via the Smartlink 2 RS-232 serial interface through a Crestron SIMPLWindows module. Provides power, source selection, volume, mute, channel tuning, and control mode switching. This spec is derived from a Crestron module integration document; the raw serial command protocol between the Crestron controller and the NET1CCI card is not documented here.
Transport
protocols:
- serial
serial:
baud_rate: 1200
data_bits: 8
parity: none
stop_bits: 1
flow_control: null # UNRESOLVED: flow control not stated in source
auth:
type: none # inferred: no auth procedure in source
Traits
traits:
- powerable # inferred from power on/off/toggle commands
- routable # inferred from input selection commands (antenna, aux, svideo, vga)
- levelable # inferred from volume up/down commands
- queryable # inferred from channel and volume feedback (simulated)
Actions
actions:
- id: power_toggle
label: Power Toggle
kind: action
params: []
notes: Pulse to turn TV on or off
- id: select_input
label: Select Input
kind: action
params:
- name: input
type: enum
values: [antenna, aux, svideo, vga]
description: Input source to select
notes: INPUT-* signal in Crestron module
- id: channel_key
label: Channel Key Entry
kind: action
params:
- name: digit
type: integer
description: Digit 0-9 for direct channel entry
notes: CHANNEL-KEY-0 through CHANNEL-KEY-9 and CLEAR
- id: channel_enter
label: Channel Enter
kind: action
params: []
notes: Pulse to send the entered channel number to the TV
- id: channel_up
label: Channel Up
kind: action
params: []
- id: channel_down
label: Channel Down
kind: action
params: []
- id: volume_up
label: Volume Up
kind: action
params: []
notes: Press and hold to ramp volume up
- id: volume_down
label: Volume Down
kind: action
params: []
notes: Press and hold to ramp volume down
- id: mute_on
label: Mute On
kind: action
params: []
- id: mute_off
label: Mute Off
kind: action
params: []
- id: mute_toggle
label: Mute Toggle
kind: action
params: []
- id: control_single
label: Control Single Mode
kind: action
params: []
notes: Single unit control mode - untested per source
- id: control_dual
label: Control Dual (Global) Mode
kind: action
params: []
notes: Global control mode for all TVs in the same group
- id: tune_cable
label: Tune Cable Mode
kind: action
params: []
- id: tune_broadcast
label: Tune Broadcast Mode
kind: action
params: []
Feedbacks
feedbacks:
- id: power_state
type: enum
values: [on, off]
notes: Simulated feedback - no true feedback from Philips system
- id: input_state
type: enum
values: [antenna, aux, svideo, vga]
notes: Simulated feedback
- id: channel
type: integer
notes: Simulated analog value showing current channel
- id: volume_level
type: integer
notes: Simulated analog value showing relative volume level
- id: mute_state
type: enum
values: [on, off]
notes: Simulated feedback
- id: control_mode
type: enum
values: [single, dual]
notes: Indicates control mode selected
- id: tune_mode
type: enum
values: [cable, broadcast]
notes: Indicates tuning mode selected
Variables
variables:
- id: channel_upper_limit
type: integer
description: Maximum channel number +1 (e.g. enter 126 for 125 channels max)
notes: CHANNEL-UPPER-LIMIT parameter in Crestron module
Events
# UNRESOLVED: no unsolicited notification events documented in source
Macros
# UNRESOLVED: no multi-step sequences documented in source
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: source does not document safety warnings, interlock procedures, or power-on sequencing
Notes
- This spec is derived from a Crestron SIMPLWindows module document, not from raw Philips serial protocol documentation. The actual serial command strings sent between the Crestron controller and the NET1CCI card are not documented here.
- Crestron hardware required: CNXCOM or ST-COM serial port.
- Cable: CNSP-614.
- Vendor firmware tested: NET1CCI card Version 1.000 on Philips ITV model PC9219 C125.
- Single control mode is untested — only global (dual) control mode has been verified.
- All feedback signals are simulated by the Crestron module; the Philips system provides no true feedback.
- TV must be set to commercial mode and control mode to "Receive" via the IR remote "A" button menu. Groups must be enabled via the "D" button menu.
Provenance
source_domains:
- community.xibo.org.uk
source_urls:
- https://community.xibo.org.uk/uploads/short-url/vwVq2nPyhJKL4kTCYpa6VYhQUa8.pdf
retrieved_at: 2026-06-12T02:49:05.649Z
last_checked_at: 2026-06-12T19:32:46.281Z
Verification Summary
verdict: verified
checked_at: 2026-06-12T19:32:46.281Z
matched_actions: 15
action_count: 15
confidence: medium
summary: "All 15 spec actions matched cleanly to Crestron module signals; all transport parameters verified verbatim in source; complete bidirectional coverage. (11 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "raw serial command strings are not documented — only Crestron module I/O signals are described"
- "single control mode operation untested per source"
- "no true device feedback exists — all feedback in the Crestron module is simulated"
- "flow control not stated in source"
- "no unsolicited notification events documented in source"
- "no multi-step sequences documented in source"
- "source does not document safety warnings, interlock procedures, or power-on sequencing"
- "raw serial command byte format/strings not documented"
- "protocol version not stated"
- "flow control setting not stated"
- "single control mode operation unverified"