Summary
The Leviton VRC0P is an RS-232 serial interface module for the Vizia RF + Z-Wave lighting control system. This spec covers ASCII programming commands for controlling Z-Wave nodes (dimmers, switches, scenes, groups, thermostats, door locks) over a serial port at 9600 baud, with optional higher baud rates.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # inferred from ON/OFF command examples
- routable # inferred from RO (routes) and group/scene commands
- queryable # inferred from ?, UP, FI query commands
- levelable # inferred from L (set level 0-100) and DI/BR dim/bright commands
Actions
# Note: message prefix ">" is required; messages use uppercase ASCII.
# Format: >N[node(s)]CMD[params] e.g. >N2ON >N2,5,10L50 >GR1
# Default baud 9600; SP command can switch baud (see communication_speed).
- id: associate_nodes
label: Start Association (N)
kind: action
command: ">N{node_list}"
params:
- name: node_list
type: string
description: Comma-separated node IDs (e.g. "2" or "2,5,10"), or empty to clear association
- id: on
label: On (ON)
kind: action
command: ">N{node_list}ON"
params:
- name: node_list
type: string
description: Comma-separated node IDs, or empty for broadcast
- id: off
label: Off (OFF)
kind: action
command: ">N{node_list}OFF"
params:
- name: node_list
type: string
description: Comma-separated node IDs, or empty for broadcast
- id: set_level
label: Set Level (L)
kind: action
command: ">N{node_list}L{level}"
params:
- name: node_list
type: string
description: Comma-separated node IDs
- name: level
type: integer
description: Light level 0-100 (percent)
- id: group_recall_on
label: Group Recall On (GR + ON)
kind: action
command: ">GR{group}\r\n>ON"
params:
- name: group
type: integer
description: Group number stored via GS command
- id: group_recall_level
label: Group Recall Set Level (GR + L)
kind: action
command: ">GR{group}\r\n>L{level}"
params:
- name: group
type: integer
description: Group number stored via GS command
- name: level
type: integer
description: Light level 0-100
- id: group_recall_dim
label: Group Recall Dim (GR + DI)
kind: action
command: ">GR{group}\r\n>DI"
params:
- name: group
type: integer
description: Group number
- id: group_recall_bright
label: Group Recall Bright (GR + BR)
kind: action
command: ">GR{group}\r\n>BR"
params:
- name: group
type: integer
description: Group number
- id: group_recall_stop
label: Group Recall Stop (GR + ST)
kind: action
command: ">GR{group}\r\n>ST"
params:
- name: group
type: integer
description: Group number
- id: group_recall_scene
label: Group Recall Scene (GR + S)
kind: action
command: ">GR{group}\r\n>S{scene},{fade}"
params:
- name: group
type: integer
description: Group number
- name: scene
type: integer
description: Scene number 1-255
- name: fade
type: integer
description: Fade rate 1-255
- id: scene_activate
label: Scene Activate (S)
kind: action
command: ">N{node_list}S{scene}"
params:
- name: node_list
type: string
description: Comma-separated node IDs
- name: scene
type: integer
description: Scene number 1-255
- id: dim
label: Dim (DI)
kind: action
command: ">N{node_list}DI"
params:
- name: node_list
type: string
description: Comma-separated node IDs
- id: bright
label: Bright (BR)
kind: action
command: ">N{node_list}BR"
params:
- name: node_list
type: string
description: Comma-separated node IDs
- id: stop
label: Stop (ST)
kind: action
command: ">N{node_list}ST"
params:
- name: node_list
type: string
description: Comma-separated node IDs
notes: "Requires 1-2 ms between DI and BR commands"
- id: send_zwave
label: Send Z-Wave Message (SE)
kind: action
command: ">N{node}SE{cmd_class},{cmd},{params}"
params:
- name: node
type: integer
description: Node ID
- name: cmd_class
type: integer
description: Z-Wave command class
- name: cmd
type: integer
description: Z-Wave command
- name: params
type: string
description: Comma-separated command-class-specific parameters
- id: secure_send
label: Secure Send Z-Wave Message (SS)
kind: action
command: ">N{node}SS{cmd_class},{cmd},{params}"
params:
- name: node
type: integer
description: Node ID (e.g. door lock)
- name: cmd_class
type: integer
description: Z-Wave command class
- name: cmd
type: integer
description: Z-Wave command
- name: params
type: string
description: Comma-separated parameters
notes: "Requires VRC0P +3 back label and RF Installer Tool as primary"
- id: request_status
label: Request Information (?)
kind: kind: action
command: ">?N{node}"
params:
- name: node
type: integer
description: Node ID
- id: update
label: Update (UP)
kind: action
command: ">N{node_list}UP"
params:
- name: node_list
type: string
description: Comma-separated node IDs
notes: "Append to control commands; wait a few seconds between control and update"
- id: find_node
label: Find Node (FI)
kind: action
command: ">FI{bbb},{ggg},{sss},{iii}"
params:
- name: bbb
type: integer
description: Basic class (1=Controller, 2=Static Controller, 3=Slave, 4=Routing Slave)
- name: ggg
type: integer
description: Generic class (16=switch, 17=dimmer, 8=thermostat)
- name: sss
type: integer
description: Specific class (0=any if omitted)
- name: iii
type: integer
description: Instance 1-232
- id: communication_speed
label: Communication Speed (SP)
kind: action
command: ">SP{x}"
params:
- name: x
type: integer
description: "Baud rate index: 0=9600 (default), 1=19200, 2=38400, 3=57600, 4=115200"
notes: "Requires VRC0P +3 back label. Returns to 9600 after power cycle."
- id: group_store
label: Group Store (GS)
kind: action
command: ">N{node_list}GS{group}"
params:
- name: node_list
type: string
description: Comma-separated node IDs
- name: group
type: integer
description: Group number to store association under
- id: program_scene
label: Program Scene (PS)
kind: action
command: ">N{node_list}PS{scene},{fade}"
params:
- name: node_list
type: string
description: Comma-separated node IDs
- name: scene
type: integer
description: Scene number 2-255
- name: fade
type: integer
description: Fade rate 1-255 (255 = default)
- id: append
label: Append (AP)
kind: action
command: ">AP{node_list},{cmd}"
params:
- name: node_list
type: string
description: Additional comma-separated node IDs
- name: cmd
type: string
description: Continuation of prior command (e.g. ON, OFF)
- id: node_name
label: Node Name (NN)
kind: action
command: ">N{node}NN{charset}{name}"
params:
- name: node
type: integer
description: Node ID
- name: charset
type: integer
description: "0=standard ASCII, 1=extended ASCII (recommended), 2=Unicode UTF-8"
- name: name
type: string
description: Up to 16 characters
- id: node_location
label: Node Location (NL)
kind: action
command: ">N{node}NL{charset}{location}"
params:
- name: node
type: integer
description: Node ID
- name: charset
type: integer
description: "0=standard ASCII, 1=extended ASCII (recommended), 2=Unicode UTF-8"
- name: location
type: string
description: Up to 16 characters
- id: default_reset
label: Default Reset (DE)
kind: action
command: ">DE"
notes: "Hold LED button on RS-232 module while sending"
- id: include_exclude
label: Include/Exclude Mode (IN)
kind: action
command: ">IN"
notes: "Puts module into include or exclude mode"
- id: abort
label: Abort (AB)
kind: action
command: ">AB"
notes: "Cancels any prior transmission from serial interface"
- id: routes
label: Routes (RO)
kind: action
command: ">RO{node},{target}"
params:
- name: node
type: integer
description: Routing slave node ID
- name: target
type: integer
description: "Target node ID; 0 deletes all routes for node"
Feedbacks
# All replies framed as <...;
- id: ack
type: enum
values: [ok, error]
description: "<Exxx reply where xxx is error code (000=no error)"
- id: error_code
type: integer
description: "0=no error, 1=wrong start symbol, 2=buffer overflow, 3=RF buffers full, 4=RF not finished, 5=unrecognized command, 6=RS232 buffer busy, 7=missing data fields, 8=cannot stop SUC mode, 9=EEPROM busy, 10=no devices found"
- id: rf_transmission_result
type: enum
values: [success, error]
description: "<X000=success, <X002=error during transmission"
- id: node_report
type: string
description: "Format <Nxxx:ccc,cmd,ppp,value. Example: <N002:044,003,000,050 = node 2 dimmer level 50%"
- id: find_node_reply
type: string
description: "<Fxxx reports node ID found by FI command"
- id: scene_report
type: string
description: "<Nxxx:044,003,###,lll,fff where ###=scene, lll=level, fff=fade rate"
- id: thermostat_report
type: string
description: "<Nxxx:068,003,mmm = thermostat mode report"
- id: multilevel_sensor_report
type: string
description: "<Nxxx:049,005,001,009,075 = temperature 75F from sensor"
- id: security_nonce
type: string
description: "<Nxxx:152,128,... = security nonce message"
- id: door_lock_battery
type: string
description: "<nxxx:000,128,003,070 = door lock battery 70% (lowercase 'n')"
Variables
# UNRESOLVED: no settable parameter variables beyond command parameters listed in Actions
Events
- id: unsolicited_node_update
description: "Device forwards Z-Wave messages not processed by the controller itself to serial output as <Nxxx:... replies"
- id: rf_transmission_complete
description: "<Xyyy reply emitted after every RF transmission finishes"
- id: network_join_event
description: "Reply emitted when module is added/removed from a Z-Wave network"
Macros
# UNRESOLVED: no multi-step macros defined in source beyond the multi-line GR+CMD patterns documented inline
Safety
confirmation_required_for:
- default_reset # DE command factory-resets the module
- abort # AB cancels any in-flight transmission
interlocks: []
# UNRESOLVED: voltage, current, wiring safety not stated in source. SS commands require VRC0P +3 back label and RF Installer Tool as primary.
Notes
- All messages start with ">" and use uppercase ASCII; max 80 chars per line (use AP to extend).
- Default serial: 9600 baud, 8N1, no flow control. SP command switches baud but returns to 9600 on power cycle.
- DI/BR commands need 1-2 ms gap; UP appended after control commands for state sync; wait a few seconds before UP.
- SP, SS, and Secure Send (SS) require VRC0P with "+3" on back label.
- "FIND" (FI) basic/generic/specific class values: 0=any, 1=Controller, 2=Static Controller, 3=Slave, 4=Routing Slave; generic 16=switch, 17=dimmer, 8=thermostat.
- Source titled "Vizia RF + RS232 Serial Interface ASCII Programming"; underlying physical product identified as Leviton SmartJack with model VRC0P.
Provenance
source_domains:
- leviton.com
- applicationmarket.crestron.com
source_urls:
- https://leviton.com/content/dam/leviton/residential/product_documents/application_note/VRC0P_ASCII_Programming_Application_Note.pdf
- https://applicationmarket.crestron.com/content/Help/Leviton/dimensions_3000.pdf
retrieved_at: 2026-09-02T17:56:09.442Z
last_checked_at: 2026-09-12T22:17:07.299Z
Verification Summary
verdict: verified
checked_at: 2026-09-12T22:17:07.299Z
matched_actions: 29
action_count: 29
confidence: medium
summary: "All 29 spec action units (N, ON, OFF, L, GR+ON/L/DI/BR/ST/S, S, DI, BR, ST, SE, SS, ?, UP, FI, SP, GS, PS, AP, NN, NL, DE, IN, AB, RO) appear verbatim in the source command table and prose; transport 9600 8N1 matches. (5 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "voltage/current/firmware compatibility not stated in source"
- "no settable parameter variables beyond command parameters listed in Actions"
- "no multi-step macros defined in source beyond the multi-line GR+CMD patterns documented inline"
- "voltage, current, wiring safety not stated in source. SS commands require VRC0P +3 back label and RF Installer Tool as primary."
- "firmware version compatibility, electrical ratings, exact Z-Wave command class catalog not enumerated in source."