Summary
Leviton VRC0P RS-232 serial interface module for Z-Wave network control. Provides serial commands to control lighting, thermostats, door locks, and other Z-Wave devices. Command format: uppercase ASCII, prefixed with >, max 80 characters per line.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none
Traits
traits:
- powerable
- levelable
- queryable
- groupable
Actions
actions:
- id: node_associate
label: Associate Node(s)
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs (e.g. "2,5,10")
description: "Associate single or group of nodes to serial interface. Send >N alone to clear current association."
examples:
- ">N2"
- ">N2,5,10"
- ">N"
- id: power_on
label: Power On
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
description: "Turn ON node or group. Send >N,ON to broadcast to all nearby nodes."
examples:
- ">N2ON"
- ">N2,5,10ON"
- ">N,ON"
- id: power_off
label: Power Off
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
description: "Turn OFF node or group."
examples:
- ">N2OFF"
- ">N2,5,10OFF"
- id: set_level
label: Set Level
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
- name: level
type: integer
description: "Light level 0-100 (%)"
description: "Set light level for dimmer node(s)."
examples:
- ">N2L50"
- ">N2,5,10L50"
- id: group_recall
label: Group Recall
kind: action
params:
- name: group_number
type: integer
description: Group number stored via GS command
description: "Select a stored group for subsequent control command."
examples:
- ">GR1"
- id: scene_activate
label: Activate Scene
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
- name: scene_number
type: integer
description: "Scene number (2-255)"
- name: fade_rate
type: integer
required: false
description: "Fade rate (1-255)"
description: "Activate a scene programmed with PS command."
examples:
- ">N2,3S2"
- ">S2,255"
- id: dim
label: Dim
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
description: "Dim light level toward 0%. Stop with ST command."
examples:
- ">N2DI"
- id: bright
label: Brighten
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
description: "Brighten light level toward 99%. Stop with ST command."
examples:
- ">N2BR"
- id: stop
label: Stop Dim/Bright
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
description: "Stop active dim/bright operation. Needs 1-2ms gap after DI/BR."
examples:
- ">N2ST"
- id: send_zwave
label: Send Z-Wave Command
kind: action
params:
- name: nodes
type: string
description: Target node ID(s)
- name: command_class
type: integer
description: Z-Wave command class number
- name: command
type: integer
description: Command number within class
- name: params
type: string
required: false
description: Additional comma-separated parameters
description: "Send raw Z-Wave message. Used for thermostat and non-lighting control."
examples:
- ">N5SE69,2"
- ">N5SE68,1,1"
- id: secure_send
label: Secure Send
kind: action
params:
- name: nodes
type: string
description: Target node ID(s)
- name: command_class
type: integer
description: Z-Wave command class number
- name: command
type: integer
description: Command number within class
- name: params
type: string
required: false
description: Additional comma-separated parameters
description: "Send encrypted Z-Wave message. Requires VRC0P with +3 label. Used for door locks."
examples:
- ">N6SS98,1,0"
- ">N6SS98,1,255"
- id: group_store
label: Group Store
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
- name: group_number
type: integer
description: Group number to store
description: "Store current association list to non-volatile memory."
examples:
- ">N2,5,10GS1"
- id: program_scene
label: Program Scene
kind: action
params:
- name: nodes
type: string
description: Comma-separated node IDs
- name: scene_number
type: integer
description: "Scene number (2-255)"
- name: fade_rate
type: integer
required: false
description: "Fade rate (1-255)"
description: "Store current light levels as a scene."
examples:
- ">N2,5,10PS2,255"
- id: append
label: Append Command
kind: action
params:
- name: continuation
type: string
description: Continuation of command exceeding 80 characters
description: "Extend a command that exceeds 80-character line limit."
examples:
- ">AP,25,26,ON"
- id: set_node_name
label: Set Node Name
kind: action
params:
- name: node
type: integer
description: Node ID
- name: charset
type: integer
description: "0=standard ASCII, 1=extended ASCII, 2=Unicode UTF8"
- name: name
type: string
description: "Name up to 16 characters"
description: "Assign name to a node."
examples:
- ">N4NN1BEDROOM DIMMER"
- id: set_node_location
label: Set Node Location
kind: action
params:
- name: node
type: integer
description: Node ID
- name: charset
type: integer
description: "0=standard ASCII, 1=extended ASCII, 2=Unicode UTF8"
- name: location
type: string
description: "Location up to 16 characters"
description: "Assign location to a node."
examples:
- ">N4NL1MASTER BEDROOM"
- id: factory_default
label: Factory Default
kind: action
params: []
description: "Reset serial interface to factory defaults. Must send DE while pressing and holding the LED button on the RS232 module."
- id: include_exclude
label: Include/Exclude
kind: action
params: []
description: "Place serial interface in Z-Wave include or exclude mode."
- id: abort
label: Abort
kind: action
params: []
description: "Cancel any previous transmission from serial interface."
- id: set_routes
label: Set Routes
kind: action
params:
- name: source_node
type: integer
description: Routing slave node ID
- name: dest_node
type: integer
description: "Destination node (0 to delete all routes)"
description: "Assign or delete return routes for routing slaves. Up to 5 routes per slave."
examples:
- ">RO2,0"
- ">RO2,10"
- id: set_baud_rate
label: Set Communication Speed
kind: action
params:
- name: speed_index
type: integer
description: "0=9600, 1=19200, 2=38400, 3=57600, 4=115200"
description: "Change serial baud rate. Requires VRC0P with +3 label. Resets to 9600 on power cycle."
examples:
- ">SP1"
Feedbacks
feedbacks:
- id: request_node_info
label: Request Node Info
type: string
description: "Request status information for a node. Response format: <Nxxx:ccc,ccc,sss,lll,fff"
examples:
- command: ">?N2"
response: "<N002:044,003,000,050"
- id: request_scene_info
label: Request Scene Info
type: string
description: "Request scene info for a node. yyy=0 returns current scene. Response: scene number, light level, fade rate."
examples:
- command: ">N2?Syyy"
response: "<N002:044,003,###,lll,fff"
- id: update
label: Update
type: string
description: "Get status of node(s) after control command. Append UP after control commands. Wait a few seconds between control and update."
examples:
- command: ">N1,10,13ON >UP"
- id: find_node
label: Find Node
type: string
description: "Find unknown node ID by device class. Response: <Fxxx where xxx is node ID."
params:
- name: basic_class
type: integer
description: "1=Controller, 2=Static Controller, 3=Slave, 4=Routing Slave"
- name: generic_class
type: integer
description: "16=switch, 17=dimmer, 8=thermostat"
- name: specific_class
type: integer
required: false
description: "Defaults to 0"
- name: instance
type: integer
required: false
description: "Instance number 1-232, defaults to 1"
examples:
- command: ">FI4,17,0,1"
response: "<F004"
- id: error_response
label: Error Response
type: enum
values:
- "E000"
- "E001"
- "E002"
- "E003"
- "E004"
- "E005"
- "E006"
- "E007"
- "E008"
- "E009"
- "E010"
description: "E000=no error, E001=wrong start symbol, E002=buffer overflow, E003=RF buffers full, E004=previous RF not finished, E005=unrecognized command, E006=buffer collision, E007=missing data fields, E008=cannot stop SUC, E009=EEPROM busy, E010=device not found"
- id: rf_transmission_result
label: RF Transmission Result
type: enum
values:
- "X000"
- "X002"
description: "X000=transmission successful, X002=transmission error"
Variables
variables:
- id: baud_rate
label: Baud Rate
type: enum
values:
- 9600
- 19200
- 38400
- 57600
- 115200
description: "Current serial baud rate. Default 9600. Reset to 9600 on power cycle."
Events
# The serial interface replies after every command and after finishing every RF transmission.
# Unsolicited messages: node status updates forwarded from Z-Wave network to serial output.
# Format: <Nxxx:ccc,ccc,... (device reports)
# Format: <nxxx:... (security responses, lowercase n)
Macros
# UNRESOLVED: no multi-step macro sequences explicitly documented
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: factory default (DE) requires physical button hold - potential safety consideration
Notes
- Commands must be uppercase. Start with
>, max 80 characters per line. Use AP command to extend beyond 80 chars. - After RF transmission completes, interface replies
<Xyyy;— wait for this before sending next command. - Secure Send (SS) requires VRC0P hardware with
+3label and RF Installer Tool as primary. - Baud rate changes via SP command persist until power cycle (reverts to 9600).
- Group Recall (GR) is two-step: select group with
>GRn, then send control command on separate line. - Update (UP) recommended after every control command to sync network controllers. Wait a few seconds between control and update.
- Error code
<E005indicates unrecognized command. Error code<E003or<E004indicates RF congestion. - Security responses use lowercase
<nprefix vs standard uppercase<N.
Provenance
source_domains:
- leviton.com
- applicationmarket.crestron.com
source_urls:
- https://leviton.com/content/dam/leviton/residential/product_documents/application_note/VRC0P_ASCII_Programming_Application_Note.pdf
- https://applicationmarket.crestron.com/content/Help/Leviton/dimensions_3000.pdf
retrieved_at: 2026-05-14T17:11:49.440Z
last_checked_at: 2026-06-02T22:08:45.379Z
Verification Summary
verdict: verified
checked_at: 2026-06-02T22:08:45.379Z
matched_actions: 21
action_count: 21
confidence: medium
summary: "All 21 spec actions traced to source (dip-safe re-verify). (8 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "exact model differences between D42AV / D4200 / D4100 not stated in source"
- "firmware version compatibility not stated in source"
- "no multi-step macro sequences explicitly documented"
- "factory default (DE) requires physical button hold - potential safety consideration"
- "maximum number of nodes / groups / scenes supported"
- "Z-Wave command class details — source references Zensys spec appendices but does not include them"
- "exact response timing requirements between commands"
- "whether TCP/IP control is available in addition to serial"
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0