Summary
Network Connect Series professional amplifier (4-channel, low-Z/Hi-Z). TCP/IP control protocol on port 4321 using ASCII command strings terminated by newline. Supports GET / SET / SUBSCRIBE / UNSUBSCRIBE against a hierarchical URL-based object/element namespace covering channel inputs, crossover, EQ, limiters, output, levels, load monitor, device info, power supply, auto-standby, and signal generator.
Transport
protocols:
- tcp
addressing:
port: 4321
auth:
type: none # inferred: no auth procedure in source (doc states TCP works even if WebUI is password-protected)
Traits
- powerable # inferred from output enable / channel-ready commands and auto-standby commands
- routable # inferred from primary/secondary input source selection commands
- queryable # inferred from GET commands returning state
- levelable # inferred from fader, gain, EQ, and threshold control commands
Actions
- id: get_element
label: Get Element Value
kind: query
command: "get <object/element>\n"
params:
- name: object_element
type: string
description: Object/element URL from the supported namespace
- id: set_element
label: Set Element Value
kind: action
command: "set <object/element> <value>\n"
params:
- name: object_element
type: string
description: Object/element URL
- name: value
type: string
description: Value to assign (string/enum values containing spaces must be enclosed in double quotes)
- id: subscribe_element
label: Subscribe to Element Changes
kind: action
command: "subscribe <object/element>\n"
params:
- name: object_element
type: string
description: Object/element URL
- id: unsubscribe_element
label: Unsubscribe from Element Changes
kind: action
command: "unsubscribe <object/element>\n"
params:
- name: object_element
type: string
description: Object/element URL
- id: set_device_name
label: Set Device Name
kind: action
command: "set /amp/deviceInfo/deviceName <value>\n"
params:
- name: value
type: string
description: Free-form device name string
- id: set_venue_name
label: Set Venue Name
kind: action
command: "set /amp/deviceInfo/venueName <value>\n"
params:
- name: value
type: string
description: Free-form venue name string
- id: get_model_id
label: Get Model ID
kind: query
command: "get /amp/deviceInfo/modelID\n"
params: []
- id: set_asset_tag_number
label: Set Asset Tag Number
kind: action
command: "set /amp/deviceInfo/assetTagNumber <value>\n"
params:
- name: value
type: string
- id: set_installer_name
label: Set Installer Name
kind: action
command: "set /amp/deviceInfo/installerName <value>\n"
params:
- name: value
type: string
- id: set_installer_contact_info
label: Set Installer Contact Info
kind: action
command: "set /amp/deviceInfo/installerContactInfo <value>\n"
params:
- name: value
type: string
- id: set_date_of_installation
label: Set Date of Installation
kind: action
command: "set /amp/deviceInfo/dateOfInstallation <value>\n"
params:
- name: value
type: string
description: ISO 8601 timestamp (e.g. "2020-02-16T20:47:00.000Z")
- id: set_rack_name
label: Set Rack Name
kind: action
command: "set /amp/deviceInfo/rackName <value>\n"
params:
- name: value
type: string
- id: set_rack_position
label: Set Rack Position
kind: action
command: "set /amp/deviceInfo/rackPosition <value>\n"
params:
- name: value
type: string
description: Free-form rack position string (e.g. "RU 1")
- id: get_ac_line_voltage
label: Get AC Line Voltage RMS
kind: query
command: "get /amp/powerSupply/acLineVoltage\n"
params: []
- id: get_ac_line_current
label: Get AC Line Current RMS
kind: query
command: "get /amp/powerSupply/acLineCurrent\n"
params: []
- id: get_ac_line_power
label: Get AC Line Power Draw
kind: query
command: "get /amp/powerSupply/acLineWatts\n"
params: []
- id: get_power_supply_fault
label: Get Power Supply Fault Status
kind: query
command: "get /amp/powerSupply/fault\n"
params: []
- id: get_power_supply_thermal
label: Get Power Supply Thermal Protection Status
kind: query
command: "get /amp/powerSupply/thermal\n"
params: []
- id: get_power_supply_power_ok
label: Get Power Supply Power OK Status
kind: query
command: "get /amp/powerSupply/powerOk\n"
params: []
- id: get_power_supply_line_warning
label: Get AC Line Voltage Ok
kind: query
command: "get /amp/powerSupply/lineWarning\n"
params: []
- id: set_auto_standby_enable
label: Set Auto Standby Enable
kind: action
command: "set /amp/autoStandby/enable <value>\n"
params:
- name: value
type: string
description: '"true" or "false"'
- id: set_auto_standby_threshold
label: Set Auto Standby Threshold
kind: action
command: "set /amp/autoStandby/threshold <value>\n"
params:
- name: value
type: number
description: Threshold in dBFS
- id: set_auto_standby_wait_time
label: Set Auto Standby Wait Time
kind: action
command: "set /amp/autoStandby/timeToWait <value>\n"
params:
- name: value
type: integer
description: Minutes (1 through 240)
- id: set_signal_generator_type
label: Set Signal Generator Type
kind: action
command: "set /amp/signalGenerator/type <value>\n"
params:
- name: value
type: enum
description: '"Pink Noise", "White Noise", or "Tone"'
- id: set_signal_generator_frequency
label: Set Signal Generator Tone Frequency
kind: action
command: "set /amp/signalGenerator/frequency <value>\n"
params:
- name: value
type: integer
description: Hz (20 through 20000)
- id: set_analog_input_sensitivity
label: Set Analog Input Sensitivity
kind: action
command: "set /amp/inputs/analog/<input>/sensitivity <value>\n"
params:
- name: input
type: integer
description: Input number
- name: value
type: enum
description: '"26dB" or "34dB"'
- id: set_primary_input_source
label: Set Primary Input Source
kind: action
command: "set /amp/channels/<channel>/inputSelector/primary <value>\n"
params:
- name: channel
type: integer
description: Channel number (1-4 on 124N)
- name: value
type: enum
description: Analog or Dante source string (Network Connect Series supports Analog inputs only)
- id: get_primary_input_source
label: Get Primary Input Source
kind: query
command: "get /amp/channels/<channel>/inputSelector/primary\n"
params:
- name: channel
type: integer
- id: set_primary_fader
label: Set Primary Gain Attenuation Fader
kind: action
command: "set /amp/channels/<channel>/inputSelector/primaryFader <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: dB (-80 through 0)
- id: get_primary_fader
label: Get Primary Gain Attenuation Fader
kind: query
command: "get /amp/channels/<channel>/inputSelector/primaryFader\n"
params:
- name: channel
type: integer
- id: subscribe_primary_input_meter
label: Subscribe to Primary Input Meter
kind: action
command: "subscribe /amp/channels/<channel>/inputSelector/primaryLevel\n"
params:
- name: channel
type: integer
- id: get_primary_signal_detect
label: Get Primary Input Signal Present
kind: query
command: "get /amp/channels/<channel>/inputSelector/primarySignalDetect\n"
params:
- name: channel
type: integer
- id: subscribe_primary_clip
label: Subscribe to Primary Input Clip Indicator
kind: action
command: "subscribe /amp/channels/<channel>/inputSelector/primaryClip\n"
params:
- name: channel
type: integer
- id: set_primary_threshold
label: Set Primary Input Signal Override Threshold
kind: action
command: "set /amp/channels/<channel>/inputSelector/primaryThreshold <value>\n"
params:
- name: channel
type: integer
- name: value
type: integer
description: dB (-80 through 0)
- id: set_secondary_input_source
label: Set Secondary Input Source
kind: action
command: "set /amp/channels/<channel>/inputSelector/secondary <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: Analog, Dante source string, or "None"
- id: get_secondary_input_source
label: Get Secondary Input Source
kind: query
command: "get /amp/channels/<channel>/inputSelector/secondary\n"
params:
- name: channel
type: integer
- id: set_secondary_fader
label: Set Secondary Gain Attenuation Fader
kind: action
command: "set /amp/channels/<channel>/inputSelector/secondaryFader <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: dB (-80 through 0)
- id: get_secondary_fader
label: Get Secondary Gain Attenuation Fader
kind: query
command: "get /amp/channels/<channel>/inputSelector/secondaryFader\n"
params:
- name: channel
type: integer
- id: subscribe_secondary_input_meter
label: Subscribe to Secondary Input Meter
kind: action
command: "subscribe /amp/channels/<channel>/inputSelector/secondaryLevel\n"
params:
- name: channel
type: integer
- id: get_secondary_signal_detect
label: Get Secondary Input Signal Present
kind: query
command: "get /amp/channels/<channel>/inputSelector/secondarySignalDetect\n"
params:
- name: channel
type: integer
- id: subscribe_secondary_clip
label: Subscribe to Secondary Input Clip Indicator
kind: action
command: "subscribe /amp/channels/<channel>/inputSelector/secondaryClip\n"
params:
- name: channel
type: integer
- id: set_secondary_threshold
label: Set Secondary Input Signal Override Threshold
kind: action
command: "set /amp/channels/<channel>/inputSelector/secondaryThreshold <value>\n"
params:
- name: channel
type: integer
- name: value
type: integer
description: dB (-80 through 0)
- id: get_input_signal_detect
label: Get Input Signal Present (Primary+Secondary aggregate)
kind: query
command: "get /amp/channels/<channel>/inputSelector/signalDetect\n"
params:
- name: channel
type: integer
- id: subscribe_input_clip
label: Subscribe to Input Clip Indicator (aggregate)
kind: action
command: "subscribe /amp/channels/<channel>/inputSelector/clip\n"
params:
- name: channel
type: integer
- id: set_input_priority_mode
label: Set Input Signal Priority Override Mode
kind: action
command: "set /amp/channels/<channel>/inputSelector/mode <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"Override" (Auto Override Primary) or "Backup" (Signal Sensing Override)'
- id: set_signal_generator_channel_enable
label: Set Signal Generator Channel Enable
kind: action
command: "set /amp/channels/<channel>/inputSelector/signalGeneratorEnable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: set_signal_generator_channel_fader
label: Set Signal Generator Channel Fader
kind: action
command: "set /amp/channels/<channel>/inputSelector/signalGeneratorFader <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: dB (-80 through 0)
- id: set_dante_on_ramp
label: Set Dante On Ramp
kind: action
command: "set /amp/channels/<channel>/inputSelector/danteOnRamp <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"Post Crossover", "Analog Input", etc. (Network Connect Series typically not applicable)'
- id: get_dante_on_ramp
label: Get Dante On Ramp
kind: query
command: "get /amp/channels/<channel>/inputSelector/danteOnRamp\n"
params:
- name: channel
type: integer
- id: set_crossover_gain
label: Set Crossover Gain
kind: action
command: "set /amp/channels/<channel>/crossover/bandGainAndDelay/gain <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: dB (-15.0 through 15.0)
- id: set_crossover_delay
label: Set Crossover Delay
kind: action
command: "set /amp/channels/<channel>/crossover/bandGainAndDelay/delay <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: ms (0.0 through 100.0)
- id: set_crossover_polarity
label: Set Crossover Polarity
kind: action
command: "set /amp/channels/<channel>/crossover/bandGainAndDelay/invert <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" (negative) or "false"'
- id: set_crossover_lowpass_enable
label: Set Crossover Low Pass Filter Enable
kind: action
command: "set /amp/channels/<channel>/crossover/lowPassFilter/enable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: set_crossover_lowpass_type
label: Set Crossover Low Pass Filter Type
kind: action
command: "set /amp/channels/<channel>/crossover/lowPassFilter/type <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: Filter type string (Butterworth/Linkwitz-Riley/Bessel 6/12/18/24/48 dB/oct)
- id: set_crossover_lowpass_frequency
label: Set Crossover Low Pass Filter Frequency
kind: action
command: "set /amp/channels/<channel>/crossover/lowPassFilter/frequency <value>\n"
params:
- name: channel
type: integer
- name: value
type: integer
description: Hz (20 through 20000)
- id: set_crossover_highpass_enable
label: Set Crossover High Pass Filter Enable
kind: action
command: "set /amp/channels/<channel>/crossover/highPassFilter/enable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: set_crossover_highpass_type
label: Set Crossover High Pass Filter Type
kind: action
command: "set /amp/channels/<channel>/crossover/highPassFilter/type <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: Filter type string (Butterworth/Linkwitz-Riley/Bessel 6/12/18/24/48 dB/oct)
- id: set_crossover_highpass_frequency
label: Set Crossover High Pass Filter Frequency
kind: action
command: "set /amp/channels/<channel>/crossover/highPassFilter/frequency <value>\n"
params:
- name: channel
type: integer
- name: value
type: integer
description: Hz (20 through 20000)
- id: set_eq_filter_enable
label: Set Output EQ Filter Enable
kind: action
command: "set /amp/channels/<channel>/outputEqFilters/<filter>/enable <value>\n"
params:
- name: channel
type: integer
- name: filter
type: integer
description: Filter number
- name: value
type: enum
description: '"true" or "false"'
- id: set_eq_filter_type
label: Set Output EQ Filter Type
kind: action
command: "set /amp/channels/<channel>/outputEqFilters/<filter>/type <value>\n"
params:
- name: channel
type: integer
- name: filter
type: integer
- name: value
type: enum
description: '"Parametric", "LP Shelf 6dB/oct", "HP Shelf 6dB/oct", "LP Shelf 12dB/oct", "HP Shelf 12dB/oct"'
- id: set_eq_filter_gain
label: Set Output EQ Filter Gain
kind: action
command: "set /amp/channels/<channel>/outputEqFilters/<filter>/gain <value>\n"
params:
- name: channel
type: integer
- name: filter
type: integer
- name: value
type: number
description: dB (-15.0 through 15.0)
- id: set_eq_filter_frequency
label: Set Output EQ Filter Frequency
kind: action
command: "set /amp/channels/<channel>/outputEqFilters/<filter>/frequency <value>\n"
params:
- name: channel
type: integer
- name: filter
type: integer
- name: value
type: integer
description: Hz (20 through 20000)
- id: set_eq_filter_q
label: Set Output EQ Filter Q
kind: action
command: "set /amp/channels/<channel>/outputEqFilters/<filter>/q <value>\n"
params:
- name: channel
type: integer
- name: filter
type: integer
- name: value
type: number
description: Q (0.1 through 24.0)
- id: set_rms_limiter_enable
label: Set RMS Limiter Enable
kind: action
command: "set /amp/channels/<channel>/rmsLimiter/enable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: set_rms_limiter_threshold
label: Set RMS Limiter Threshold
kind: action
command: "set /amp/channels/<channel>/rmsLimiter/threshold <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: V (10.0 through 140.0)
- id: set_rms_limiter_attack
label: Set RMS Limiter Attack Time
kind: action
command: "set /amp/channels/<channel>/rmsLimiter/attackTime <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: ms (1000.0 through 10000.0)
- id: set_rms_limiter_release
label: Set RMS Limiter Release Time
kind: action
command: "set /amp/channels/<channel>/rmsLimiter/releaseTime <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: ms (1000.0 through 10000.0)
- id: subscribe_rms_limiter_gain_reduction
label: Subscribe to RMS Limiter Speaker Limiter Reduction
kind: action
command: "subscribe /amp/channels/<channel>/rmsLimiter/gainReduction\n"
params:
- name: channel
type: integer
- id: subscribe_rms_limiter_total_gain_reduction
label: Subscribe to RMS Limiter Protection Limiter Reduction
kind: action
command: "subscribe /amp/channels/<channel>/rmsLimiter/totalGainReduction\n"
params:
- name: channel
type: integer
- id: set_peak_limiter_enable
label: Set Peak Limiter Enable
kind: action
command: "set /amp/channels/<channel>/peakLimiter/enable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: set_peak_limiter_threshold
label: Set Peak Limiter Threshold
kind: action
command: "set /amp/channels/<channel>/peakLimiter/threshold <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: V (14.0 through 198.0)
- id: set_peak_limiter_attack
label: Set Peak Limiter Attack Time
kind: action
command: "set /amp/channels/<channel>/peakLimiter/attackTime <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: ms (1.0 through 1000.0)
- id: set_peak_limiter_release
label: Set Peak Limiter Release Time
kind: action
command: "set /amp/channels/<channel>/peakLimiter/releaseTime <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: ms (1.0 through 1000.0)
- id: subscribe_peak_limiter_gain_reduction
label: Subscribe to Peak Limiter Speaker Limiter Reduction
kind: action
command: "subscribe /amp/channels/<channel>/peakLimiter/gainReduction\n"
params:
- name: channel
type: integer
- id: subscribe_peak_limiter_total_gain_reduction
label: Subscribe to Peak Limiter Protection Limiter Reduction
kind: action
command: "subscribe /amp/channels/<channel>/peakLimiter/totalGainReduction\n"
params:
- name: channel
type: integer
- id: set_output_name
label: Set Output Channel Name
kind: action
command: "set /amp/channels/<channel>/output/name <value>\n"
params:
- name: channel
type: integer
- name: value
type: string
- id: get_output_name
label: Get Output Channel Name
kind: query
command: "get /amp/channels/<channel>/output/name\n"
params:
- name: channel
type: integer
- id: set_output_enable
label: Set Output Channel Ready Enable
kind: action
command: "set /amp/channels/<channel>/output/enable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: set_output_mute
label: Set Output Channel Mute
kind: action
command: "set /amp/channels/<channel>/output/mute <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: get_output_mute
label: Get Output Channel Mute
kind: query
command: "get /amp/channels/<channel>/output/mute\n"
params:
- name: channel
type: integer
- id: set_output_fader
label: Set Output Channel Gain Attenuation Fader
kind: action
command: "set /amp/channels/<channel>/output/fader <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: dB (-80.0 through 0.0)
- id: get_output_fader
label: Get Output Channel Gain Attenuation Fader
kind: query
command: "get /amp/channels/<channel>/output/fader\n"
params:
- name: channel
type: integer
- id: set_output_hiz_loz_mode
label: Set Output Channel Hi-Z Low-Z Mode
kind: action
command: "set /amp/channels/<channel>/output/hiZLoZ <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"HiZ-70V", "HiZ-100V", or "LoZ"'
- id: set_output_hiz_hpf_frequency
label: Set Output Channel Hi-Z Mode High Pass Frequency
kind: action
command: "set /amp/channels/<channel>/output/hiZHpfFrequency <value>\n"
params:
- name: channel
type: integer
- name: value
type: integer
description: Hz (35 through 5000)
- id: get_output_fault
label: Get Output Channel Fault
kind: query
command: "get /amp/channels/<channel>/output/fault\n"
params:
- name: channel
type: integer
- id: get_output_thermal
label: Get Output Channel Thermal Fault
kind: query
command: "get /amp/channels/<channel>/output/thermal\n"
params:
- name: channel
type: integer
- id: get_output_limiting
label: Get Output Channel Limiting
kind: query
command: "get /amp/channels/<channel>/output/limiting\n"
params:
- name: channel
type: integer
- id: get_output_clip
label: Get Output Channel Clip
kind: query
command: "get /amp/channels/<channel>/output/clip\n"
params:
- name: channel
type: integer
- id: get_output_signal_detect
label: Get Output Channel Signal Presence
kind: query
command: "get /amp/channels/<channel>/output/signalDetect\n"
params:
- name: channel
type: integer
- id: get_output_ready
label: Get Output Channel Ready Indicator
kind: query
command: "get /amp/channels/<channel>/output/ready\n"
params:
- name: channel
type: integer
- id: get_output_level_db
label: Get Output Channel Meter Level dBFS
kind: query
command: "get /amp/channels/<channel>/levels/level_db\n"
params:
- name: channel
type: integer
- id: get_output_level_volts
label: Get Output Channel Level Volts RMS
kind: query
command: "get /amp/channels/<channel>/levels/level_volts\n"
params:
- name: channel
type: integer
- id: get_output_level_watts
label: Get Output Channel Level Watts RMS
kind: query
command: "get /amp/channels/<channel>/levels/level_watts\n"
params:
- name: channel
type: integer
- id: set_load_monitor_enable
label: Set Load Monitor Enable
kind: action
command: "set /amp/channels/<channel>/loadMonitor/enable <value>\n"
params:
- name: channel
type: integer
- name: value
type: enum
description: '"true" or "false"'
- id: get_load_monitor_measured_impedance
label: Get Load Monitor Measured Impedance
kind: query
command: "get /amp/channels/<channel>/loadMonitor/measuredImpedance\n"
params:
- name: channel
type: integer
- id: set_load_monitor_high_limit
label: Set Load Monitor High Limit
kind: action
command: "set /amp/channels/<channel>/loadMonitor/highLimit <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: Ohms (8.0 through 250.0)
- id: set_load_monitor_low_limit
label: Set Load Monitor Low Limit
kind: action
command: "set /amp/channels/<channel>/loadMonitor/lowLimit <value>\n"
params:
- name: channel
type: integer
- name: value
type: number
description: Ohms (1.0 through 250.0)
- id: get_load_monitor_status
label: Get Load Monitor Status
kind: query
command: "get /amp/channels/<channel>/loadMonitor/status\n"
params:
- name: channel
type: integer
Feedbacks
- id: ac_line_voltage_rms
type: number
description: AC line voltage in V (0.0-300.0)
- id: ac_line_current_rms
type: number
description: AC line current in A (0.0-100.0)
- id: ac_line_power_watts
type: number
description: AC line power draw in W (0.0-5000.0)
- id: power_supply_fault
type: boolean
- id: power_supply_thermal
type: boolean
- id: power_supply_power_ok
type: boolean
- id: power_supply_line_warning
type: boolean
- id: primary_signal_detect
type: boolean
- id: primary_clip
type: boolean
- id: primary_input_level_dbfs
type: number
description: dBFS (-80 to 0)
- id: secondary_signal_detect
type: boolean
- id: secondary_clip
type: boolean
- id: secondary_input_level_dbfs
type: number
- id: input_signal_detect
type: boolean
description: Aggregate primary+secondary
- id: input_clip
type: boolean
description: Aggregate primary+secondary
- id: rms_limiter_speaker_gain_reduction
type: number
description: Active gain reduction from user-defined RMS limiter
- id: rms_limiter_total_gain_reduction
type: number
description: Total active gain reduction including internal protection
- id: peak_limiter_speaker_gain_reduction
type: number
- id: peak_limiter_total_gain_reduction
type: number
- id: output_fault
type: boolean
- id: output_thermal
type: boolean
- id: output_limiting
type: boolean
- id: output_clip
type: boolean
- id: output_signal_detect
type: boolean
- id: output_ready
type: boolean
- id: output_level_dbfs
type: number
- id: output_level_volts_rms
type: number
- id: output_level_watts_rms
type: number
- id: load_monitor_measured_impedance
type: number
description: Ohms (0.0-250.0)
- id: load_monitor_status
type: enum
values: [Ok, Short, Open, Low Signal]
- id: ok_response
type: enum
values: [OK]
description: Standard success response for SET and UNSUBSCRIBE
- id: error_response
type: string
description: Error messages begin with the prefix "error:"
Variables
# No additional settable scalar variables beyond what is captured in Actions.
Events
# SUBSCRIBE commands produce asynchronous notifications on the same TCP connection.
# Notification payload format mirrors the GET response: "<object/element> <value>\n".
# Examples:
# /amp/channels/1/levels/level_db -52.78131103515625\n
# /amp/channels/1/inputSelector/danteOnRamp "Post Crossover"\n
Macros
# UNRESOLVED: source does not define multi-step macro sequences
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: source contains power-supply fault/thermal protection sensors but no explicit
# safety interlock procedures or confirmation requirements
Notes
Source document covers the LEA Connect Series protocol (Network Connect and Dante Connect). The LEA 124N is a 4-channel Network Connect Series amplifier with no Dante inputs. Per the source, Network Connect Series supports only Analog inputs (limited to the number of channels on the amplifier) and Dante elements are not applicable to a 124N.
- TCP port: 4321 (verified). All messages are newline (0x0a) delimited. Out-of-range numeric values are clamped silently. Illegal commands produce
error: ...responses. - Auth: source states TCP communication works even if the WebUI is password-protected; no auth handshake is documented.
- Firmware: source states "LEA Connect Firmware version 1.1.0.29 and higher" supports TCP; earlier versions only support WebSocket. Per-device firmware for the 124N itself is not stated.
- For Network Connect Series, Dante-related elements (Dante sources, danteOnRamp) are not applicable.
- Crossover high-pass filter URL is sometimes given with
lowPassFilterin the source's HP filter type example — likely a doc typo; URL follows element namehighPassFilter. /amp/deviceInfo/venueNameexample response in source shows a model ID value ("Connect Series Model 704D") — likely doc typo; URL is/amp/deviceInfo/modelIDper the "Model ID" section.get /amp/powerSupply/faultexample response shows theacLineWattsURL — likely doc typo; expected response is the fault boolean value.get /amp/channels/1/loadMonitor/measuredImpedanceexample response shows/amp/channels/1/level— likely doc typo; expected response is the impedance value.get /amp/channels/1/loadMonitor/statusexample response shows/amp/channels/1/level— likely doc typo.
Provenance
source_domains:
- leaprofessional.com
source_urls:
- https://leaprofessional.com/wp-content/uploads/2020/06/LEA-Open-API-TCP-Protocol-June-2020.pdf
- https://leaprofessional.com/download/websocket-control-api/
- https://leaprofessional.com/download/users-manual-network-connect-series/
- https://leaprofessional.com/downloads/
retrieved_at: 2026-07-01T13:55:44.751Z
last_checked_at: 2026-07-07T11:46:01.098Z
Verification Summary
verdict: verified
checked_at: 2026-07-07T11:46:01.098Z
matched_actions: 98
action_count: 98
confidence: medium
summary: "All 98 spec actions matched verbatim to source URLs; transport parameters (TCP port 4321, no auth) verified. (4 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "spec applies to LEA Connect Series broadly (Network and Dante Connect); per-channel URL uses \"x\" and input uses \"#\" placeholders that depend on the specific amplifier model. 124N is a 4-channel Network Connect Series amplifier. Source does not enumerate channel counts or per-model availability for each element — see Notes."
- "source does not define multi-step macro sequences"
- "source contains power-supply fault/thermal protection sensors but no explicit"
- "source describes the protocol generically for all Connect Series models; device-specific channel count, available inputs/outputs, and per-model element availability for the 124N must be confirmed from LEA product documentation."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0