Summary
The NLB 60E is a NomadLink bridge/controller for Lab.gruppen amplifiers. Third-party control via text-based TCP on port 65010. Supports subnet-level and per-device control for power, mute, and status monitoring. Commands are case-insensitive alphanumerical strings terminated with CR+LF.
Transport
protocols:
- tcp
addressing:
port: 65010 # stated: "3rd party control 65010"
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # Power On/Off commands present for subnet and individual devices
- routable # VDN-based device addressing provides routing capability
- queryable # Status, MuteStatus, StatusOk queries present
Actions
- id: subnet_power_set
label: Set Subnet Power
kind: action
params:
- name: value
type: integer
description: 0 = off, 1 = on
- id: subnet_power_get
label: Get Subnet Power
kind: action
params: []
- id: subnet_mute_set
label: Set Subnet Mute
kind: action
params:
- name: value
type: integer
description: 0 = unmute, 1 = mute
- id: subnet_mute_get
label: Get Subnet Mute
kind: action
params: []
- id: subnet_statusok
label: Get Subnet Status OK
kind: action
params: []
- id: subnet_status
label: Get Subnet Status
kind: action
params: []
- id: subnet_serial_at_pos
label: Get Subnet Serial at Position
kind: action
params:
- name: position
type: integer
description: Position 1-60
- id: subnet_vdn_set
label: Set Subnet VDN Entry
kind: action
params:
- name: index
type: integer
description: VDN slot 1-60
- name: vdn
type: string
description: Virtual device name (alphanumerical, '@', '-', max 10 chars)
- name: serial
type: string
description: Serial number to associate
- id: device_power_set
label: Set Device Power
kind: action
params:
- name: vdn
type: string
description: Virtual device name
- name: value
type: integer
description: 0 = off, 1 = on
- id: device_power_get
label: Get Device Power
kind: action
params:
- name: vdn
type: string
- id: device_mute_set
label: Set Device Channel Mute
kind: action
params:
- name: vdn
type: string
- name: channel
type: string
description: Channel A, B, C, D, E, F, G, or H
- name: value
type: integer
description: 0 = unmute, 1 = mute
- id: device_mute_get
label: Get Device Channel Mute
kind: action
params:
- name: vdn
type: string
- name: channel
type: string
- id: device_mute_status
label: Get Device Mute Status (all channels)
kind: action
params:
- name: vdn
type: string
- id: device_status
label: Get Device Status
kind: action
params:
- name: vdn
type: string
Feedbacks
- id: subnet_power_state
label: Subnet Power State
type: enum
values:
- 0 # all off
- 1 # all on
- 2 # mixed
- 3 # in transition
- id: subnet_mute_state
label: Subnet Mute State
type: enum
values:
- 0 # unmute
- 1 # muted
- id: subnet_statusok
label: Subnet Status OK
type: enum
values:
- 0 # faults present
- 1 # no faults
- id: subnet_status
label: Subnet Status Reply
type: string
description: >
Whitespace-separated: subnet_number device_count mute_state loop_state
GPI1 GPI2 GPI3 power_status fault_present [fault_vdn_list]
- id: subnet_serial_at_pos
label: Subnet Serial at Position Reply
type: string
- id: subnet_vdn_reply
label: Subnet VDN Reply
type: string
description: "VDN serial_number space-separated. '*' means unassigned."
- id: device_power_state
label: Device Power State
type: enum
values:
- 0 # desired off
- 1 # desired on
- id: device_mute_state
label: Device Channel Mute State
type: enum
values:
- 0 # unmute
- 1 # muted
- id: device_mute_status_all
label: Device Mute Status All Channels
type: string
description: "8 values (A-H) space-separated. 0=unmute, 1=mute."
- id: device_status_reply
label: Device Status Reply
type: string
description: >
fault_flag power_warning PAL_active [channel_data...] each channel:
attenuation_dB VPL_flag CPL_flag VHF_fault DC_fault
load_short_fault temp_fault high_imp_warning temp_warning
- id: error
label: Error Reply
type: string
description: "'ERROR! <message>' format. Messages: parse error, VDN not found, device not found, Device Control connected, channel out of range, internal error."
Variables
# UNRESOLVED: no discrete settable parameters beyond VDN table management
Events
# UNRESOLVED: no unsolicited event notifications described in source
Macros
# UNRESOLVED: no multi-step sequences described in source
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings, interlock procedures, or power-on sequencing in source
Notes
VDN format: up to 10 alphanumerical chars, '@' and '-' allowed. Whitespace and 'Subnet' forbidden. Serial number associates to one VDN only. Up to 60 VDNs per bridge. Source recommends static IP for fixed installs.
Message format: AddressContext.Parameter = value (set) or AddressContext.Parameter ? (get). Reply to set = same as get reply. All strings case-insensitive, terminated CR+LF.
Subnet power transition: reply may be "In transition" (value 3) while devices change state.
Error format: ERROR! <description>. Possible errors: parse failure, VDN does not exist, Device not found, Device Control connected, channel out of range, internal error code.
Provenance
source_domains:
- prodgsystems.com
source_urls:
- "https://prodgsystems.com/public/pdf/119_Third%20party%20integration%20protocol.pdf"
retrieved_at: 2026-04-30T04:36:28.729Z
last_checked_at: 2026-06-02T22:08:39.377Z
Verification Summary
verdict: verified
checked_at: 2026-06-02T22:08:39.377Z
matched_actions: 14
action_count: 14
confidence: medium
summary: "All 14 spec actions traced to source (dip-safe re-verify). (8 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "no safety warnings or interlock procedures in source"
- "no discrete settable parameters beyond VDN table management"
- "no unsolicited event notifications described in source"
- "no multi-step sequences described in source"
- "no safety warnings, interlock procedures, or power-on sequencing in source"
- "power-on sequencing not described"
- "firmware compatibility range not stated"
- "physical connection type (ethernet port) not stated"