KD-MAX8x8 is an eight-input, eight-output audio matrix switcher controllable through bidirectional RS-232 or TCP/IP. This spec covers routing, input and output configuration, DSP adjustment, network setup, system configuration, and status commands.
Transport
protocols:
- serial
- tcp
addressing:
port: 23
serial:
baud_rate: 57600
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Commands require a carriage return terminator, are not case-sensitive, and must be sent without the spaces shown for readability. Device sends a prompt after receiving a command. Default static IP address is 192.168.1.239.
Traits
- powerable # inferred from power commands
- routable # inferred from input/output routing commands
- queryable # inferred from help, name-read, and status commands
- levelable # inferred from volume and DSP commands
Actions
- id: power_on
label: Power On
kind: action
command: "PN"
params: []
- id: power_off
label: Power Off
kind: action
command: "PF"
params: []
- id: use_system_address_prefix
label: Use System Address Prefix
kind: action
command: "Azz"
params:
- name: address
type: integer
description: System address zz from 01 through 99
- id: help
label: Show Help
kind: query
command: "H"
params: []
- id: global_system_status
label: Show Global System Status
kind: query
command: "STA"
params: []
- id: set_analog_input_type
label: Set Analog Input Type
kind: action
command: "SPIxx AS y"
params:
- name: input
type: string
description: Input xx from 01 through 08, or A for all inputs
- name: type
type: integer
description: "1=L+/R+, 2=L-/R-, 3=Balanced"
- id: set_input_audio_association
label: Set Input Audio Association
kind: action
command: "SPIxx AA y"
params:
- name: input
type: string
description: Input xx from 01 through 08, or A for all inputs
- name: association
type: integer
description: "1=Analog, 2=PCM, 3=Both (Analog to Analog and PCM to PCM)"
- id: save_input_name
label: Save Input Name
kind: action
command: "SPIxx WN cccccccccccccccc"
params:
- name: input
type: string
description: Input xx from 01 through 08, or A for all inputs
- name: name
type: string
description: Input name represented by cccccccccccccccc
- id: read_input_name
label: Read Input Name
kind: query
command: "SPIxx RN"
params:
- name: input
type: string
description: Input xx from 01 through 08, or A for all inputs
- id: route_associated_input
label: Route Associated Input to Output
kind: action
command: "SPOxx SI yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: input
type: integer
description: Input yy from 01 through 08
- id: route_analog_input
label: Route Analog Input to Output
kind: action
command: "SPOxx SA yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: input
type: integer
description: Analog input yy from 01 through 08
- id: route_pcm_input
label: Route PCM Input to Output
kind: action
command: "SPOxx SP yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: input
type: integer
description: PCM input yy from 01 through 08
- id: route_pcm_output
label: Route PCM Input to PCM Output
kind: action
command: "SPOxx SB yy"
params:
- name: output
type: string
description: PCM output xx from 01 through 08, or A for all outputs
- name: input
type: integer
description: PCM input yy from 01 through 08
- id: set_output_disconnection
label: Set Output Disconnection
kind: action
command: "SPOxx D E/D"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: state
type: enum
values:
- E
- D
description: Enable or disable output disconnection
- id: save_output_name
label: Save Output Name
kind: action
command: "SPOxx WN cccccccccccccccc"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: name
type: string
description: Output name represented by cccccccccccccccc
- id: read_output_name
label: Read Output Name
kind: query
command: "SPOxx RN"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- id: set_output_volume
label: Set Output Audio Volume
kind: action
command: "SPOxx AV yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: level
type: string
description: Value yy from 00 through 99, U for up, or D for down
- id: set_output_balance
label: Set Output Audio Balance
kind: action
command: "SPOxx AB yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: level
type: string
description: Value yy from 00 through 40, U for up, or D for down
- id: set_output_bass_gain
label: Set Output Audio Bass Gain
kind: action
command: "SPOxx AL yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: level
type: string
description: Value yy from 00 through 24, U for up, or D for down
- id: set_output_middle_gain
label: Set Output Audio Middle Gain
kind: action
command: "SPOxx AM yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: level
type: string
description: Value yy from 00 through 24, U for up, or D for down
- id: set_output_treble_gain
label: Set Output Audio Treble Gain
kind: action
command: "SPOxx AH yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: level
type: string
description: Value yy from 00 through 24, U for up, or D for down
- id: set_output_audio_delay
label: Set Output Audio Delay
kind: action
command: "SPOxx AD yy"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: delay
type: string
description: Value yy from 00 through 99, U for up, or D for down
- id: set_output_audio_mute
label: Set Output Audio Mute
kind: action
command: "SPOxx A E/D/T"
params:
- name: output
type: string
description: Output xx from 01 through 08, or A for all outputs
- name: state
type: enum
values:
- E
- D
- T
description: Enable, disable, or toggle mute
- id: set_host_ip_address
label: Set Host IP Address
kind: action
command: "SPCETIPA xxx.xxx.xxx.xxx"
params:
- name: address
type: string
description: IPv4 address with each xxx octet from 000 through 255
- id: set_network_mask
label: Set Network Mask
kind: action
command: "SPCETIPM xxx.xxx.xxx.xxx"
params:
- name: mask
type: string
description: IPv4 network mask with each xxx octet from 000 through 255
- id: set_router_ip_address
label: Set Router IP Address
kind: action
command: "SPCETIPR xxx.xxx.xxx.xxx"
params:
- name: address
type: string
description: IPv4 router address with each xxx octet from 000 through 255
- id: set_tcp_ip_port
label: Set TCP/IP Port
kind: action
command: "SPCETIPP zzzz"
params:
- name: port
type: integer
description: TCP/IP port zzzz from 0001 through 9999
- id: apply_network_configuration
label: Apply New Network Configuration
kind: action
command: "SPCETIPB"
params: []
- id: set_front_panel_buttons
label: Set Front Panel Buttons
kind: action
command: "SPCFB E/D"
params:
- name: state
type: enum
values:
- E
- D
description: Enable or disable front-panel buttons
- id: set_rs232_baud_rate
label: Set RS-232 Baud Rate
kind: action
command: "SPC RSB z"
params:
- name: rate_code
type: integer
description: "0=57600, 1=38400, 2=19200, 3=9600, 4=4800"
- id: reset_factory_defaults
label: Reset All to Factory Defaults
kind: action
command: "SPCDF"
params: []
- id: set_system_address
label: Set System Address
kind: action
command: "SPCAxx"
params:
- name: address
type: integer
description: System address xx from 00 through 99; 00 selects single-unit mode
Feedbacks
- id: command_prompt
type: string
description: Prompt sent after a new command is received
- id: help_response
type: string
description: Readable response containing the entire API
- id: global_system_status
type: object
description: Readable STA response containing unit and system status
fields:
- system_address
- firmware_version
- rs232_baud_rate
- rs232_data_bits
- rs232_parity
- rs232_stop_bits
- front_panel_button_state
- mac_address
- host_ip_address
- network_mask
- router_ip_address
- tcp_port
- analog_input_types
- output_routes
- output_volume
- output_balance
- output_bass
- output_middle
- output_treble
- output_delay
- output_mute
- output_enabled
- id: input_name
type: string
description: Input name returned by the SPIxx RN query
- id: output_name
type: string
description: Output name returned by the SPOxx RN query
Variables
- id: system_address
type: integer
range:
minimum: 0
maximum: 99
- id: host_ip_address
type: string
- id: network_mask
type: string
- id: router_ip_address
type: string
- id: tcp_port
type: integer
range:
minimum: 1
maximum: 9999
- id: output_volume
type: integer
range:
minimum: 0
maximum: 99
- id: output_balance
type: integer
range:
minimum: 0
maximum: 40
- id: output_bass_gain
type: integer
range:
minimum: 0
maximum: 24
- id: output_middle_gain
type: integer
range:
minimum: 0
maximum: 24
- id: output_treble_gain
type: integer
range:
minimum: 0
maximum: 24
- id: output_audio_delay
type: integer
range:
minimum: 0
maximum: 99
Events
# UNRESOLVED: source does not document unsolicited event notifications beyond a prompt after each received command
Macros
# UNRESOLVED: source does not document control-protocol macros
Safety
confirmation_required_for:
- reset_factory_defaults
- apply_network_configuration
interlocks:
- operation: firmware_mode_switch
requirement: Change switch position only while unit is not powered
Notes
Factory-default network configuration is host IP 192.168.1.239, router IP 192.168.1.1, and TCP port 23. Factory-default RS-232 configuration is 57600 baud, 8 data bits, no parity, one stop bit, and no flow control.
The firmware mode switch should remain in the Operation setting unless Key Digital technical support instructs otherwise. Setting it to F/W Load places the unit in bootloader mode awaiting firmware.
Provenance
source_domains:
- keydigital.org
source_urls:
- https://www.keydigital.org/web/content/5870/KD-MAX8x8_Manual.pdf
retrieved_at: 2026-07-14T06:07:01.920Z
last_checked_at: 2026-07-21T23:14:36.098Z
Verification Summary
verdict: verified
checked_at: 2026-07-21T23:14:36.098Z
matched_actions: 32
action_count: 32
confidence: medium
summary: "All 32 spec actions match verbatim in source with correct parameter ranges; transport parameters verified exactly. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "source identifies model as KD-MAX8x8 but does not explicitly identify the 1102 variant."
- "firmware compatibility range not stated in source."
- "source does not document unsolicited event notifications beyond a prompt after each received command"
- "source does not document control-protocol macros"
- "exact prompt syntax and general command acknowledgement/error response formats are not stated in source."
- "timing requirements, fault behavior, and error-recovery sequences are not stated in source."
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0