Summary
Hisense 100E80KUA Series commercial display (100-inch 4K UHD). Controls via RS-232 using HEX command protocol with XOR check bit. Supports power on/off, input selection, volume control, and query of power state, input, volume, and software version. The source identifies screen IDs 01–FF. The broadcast byte position is UNRESOLVED because the source gives conflicting placeholder assignments.
Transport
protocols:
- serial
serial:
baud_rate: 115200
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: UNRESOLVED
Traits
- powerable
- routable
- levelable
- queryable
Actions
- id: power_on
label: Power On
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 18 02 yy"
example: "A6 01 00 00 00 04 01 18 02 B8"
notes: Screen ID 01. Requires UART Wake On enabled.
- id: power_off
label: Power Off
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 18 01 yy"
example: UNRESOLVED
notes: The source command and example conflict; the example is not a Power Off command.
- id: set_hdmi1_input
label: HDMI 1 Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 0D yy"
example: "A6 01 00 00 00 04 01 AC 0D 03"
- id: set_hdmi2_input
label: HDMI 2 Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 06 yy"
example: "A6 01 00 00 00 04 01 AC 06 08"
- id: set_ops_input
label: OPS Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 0B yy"
example: "A6 01 00 00 00 04 01 AC 0B 05"
- id: set_cms_input
label: CMS Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 15 yy"
example: "A6 01 00 00 00 04 01 AC 15 1B"
- id: set_pdf_input
label: PDF Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 17 yy"
example: "A6 01 00 00 00 04 01 AC 17 19"
- id: set_media_input
label: Media Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 16 yy"
example: "A6 01 00 00 00 04 01 AC 16 18"
- id: set_usb_input
label: USB Input
kind: action
params: []
hex: "A6 xx 00 00 00 04 01 AC 0C yy"
example: "A6 01 00 00 00 04 01 AC 0C 02"
- id: set_volume
label: Set Volume
kind: action
params:
- name: level
type: integer
description: Volume level 0-100 (hex 00-64)
range: [0, 100]
hex: "A6 xx 00 00 00 04 01 44 vv yy"
example: "A6 01 00 00 00 04 01 44 4D AB"
notes: vv is volume in hex. Example vv=4D is volume 77.
- id: set_mains_application_mode
label: Set Mains Application Mode
kind: action
params:
- name: mode
type: integer
description: "00=Standby, 01=Power On, 02=Last known state"
values:
0: Standby
1: Power On
2: Last known state
hex: "A6 01 00 00 00 04 01 A3 ww yy"
example: "A6 01 00 00 00 04 01 A3 00 01"
- id: source_menu
label: Source Menu
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 FA E9"
- id: settings_menu
label: Settings Menu
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 FD EE"
- id: nav_up
label: Up
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 67 74"
- id: nav_down
label: Down
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 6C 7F"
- id: nav_ok
label: Ok
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 1C 0F"
- id: nav_right
label: Right
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 6A 79"
- id: nav_left
label: Left
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 69 7A"
- id: nav_home
label: Home
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 66 75"
- id: vol_up
label: Vol+
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 73 60"
- id: vol_down
label: Vol-
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 72 61"
- id: nav_return
label: Return
kind: action
params: []
hex: "A6 01 00 00 00 05 01 B0 00 9E 8D"
notes: Matches the E-series source table.
Feedbacks
- id: query_input_selection
label: Query Input Selection
kind: query
query_command: "A6 xx 00 00 00 03 01 AD yy"
hex_request: "A6 xx 00 00 00 03 01 AD yy"
hex_response: "zz = current input code"
values_map:
0D: HDMI 1
06: HDMI 2
0B: OPS
15: CMS
17: PDF
16: Media
0C: USB
14: Home Screen
- id: query_power_state
label: Query Power State
kind: query
query_command: "A6 xx 00 00 00 03 01 19 yy"
hex_request: "A6 xx 00 00 00 03 01 19 yy"
hex_response: "zz = power state"
values_map:
01: Off
02: On
- id: query_software_version
label: Query Software Version
kind: query
query_command: "A6 xx 00 00 00 04 01 A2 02 yy"
hex_request: "A6 xx 00 00 00 04 01 A2 02 yy"
notes: Returns platform version.
- id: query_volume_level
label: Query Volume Level
kind: query
query_command: "A6 xx 00 00 00 03 01 45 yy"
hex_request: "A6 xx 00 00 00 03 01 45 yy"
notes: Returns current volume as hex.
Variables
# UNRESOLVED: no discrete settable parameters beyond actions listed above
Events
# UNRESOLVED: no unsolicited event notifications documented
Macros
# UNRESOLVED: no multi-step macro sequences documented
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: safety procedures not stated in source
Notes
- HEX bytes only — commands are NOT ASCII. Do not send ASCII representations of these codes.
- Screen ID (xx): The E-series command table and examples place the screen ID in
xx; the source states IDs 01–FF. - Check bit (yy): XOR the bytes highlighted in the source. It changes with the screen ID; do not reuse a check bit from one screen ID on another. The source's introductory broadcast note assigns broadcast value 00 to
yy, conflicting with its command examples and closing placeholder definitions; broadcast addressing is UNRESOLVED. - Volume table: hex values 00–64 (0–100) defined in back of vendor manual. Not reproduced here.
- Wake On function must be enabled for Power On via RS-232 to work.
- M-series and WR-series protocols exist in source but differ significantly (different baud rates, different command structures). This spec covers E-series protocol only.
- Pin configuration for E-series RJ-45: pin 4=GND, pin 5=RX, pin 7=TX. DB-9F: pin 2=RX, pin 3=TX, pin 5=GND. RJ45↔DB-9F mapping: RJ45-4→DB9-5, RJ45-5→DB9-2, RJ45-7→DB9-3.
Provenance
source_domains:
- hisense-b2b.com
source_urls:
- "https://www.hisense-b2b.com/Attachment/DownloadFile?downloadId=5"
retrieved_at: 2026-07-13T23:18:41.782Z
last_checked_at: 2026-10-07T13:31:56.206Z
Verification Summary
verdict: verified
checked_at: 2026-10-07T13:31:56.206Z
matched_actions: 26
action_count: 26
confidence: medium
summary: "All 26 E-series action units match the source frames and serial parameters; M and WR series sections excluded as other product lines. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "whether this device additionally supports IP/Telnet control — not stated in source"
- "no discrete settable parameters beyond actions listed above"
- "no unsolicited event notifications documented"
- "no multi-step macro sequences documented"
- "safety procedures not stated in source"
- "firmware version compatibility not stated in source"
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0