Summary
The Extron DP DA2 (part 60-1221-01) is a two-output DisplayPort v1.1a distribution amplifier with EDID Minder, Key Minder (HDCP), and output muting. It is controlled via RS-232 (rear 5-pole captive screw Remote connector or front panel Config USB port) using the Extron Simple Instruction Set (SIS). This spec covers the SIS command set: video/audio mute, signal/HDCP status, EDID Minder queries, video bit depth, DDC speed, and unit identity.
Transport
protocols:
- serial
serial:
baud_rate: 9600
data_bits: 8
parity: none
stop_bits: 1
flow_control: null # UNRESOLVED: flow control not stated in source
auth:
type: none # inferred: no auth procedure in source
Traits
traits:
- queryable # inferred: mute/signal/HDCP/EDID/bitdepth/DDC/name/version queries present
Actions
# SIS symbol legend (verbatim from source Symbol table):
# E = Escape (0x1B) - prefix for many commands
# } = Carriage return (0x0D), no line feed - command terminator
# ] = Carriage return + line feed (0x0D 0x0A) - response terminator
# • / space = literal space character (0x20)
# Variables:
# X! = video output (1 or 2) X@ = status (0=off, 1=on)
# X( = bit depth (0=Auto, 1=8bit) X* = DDC speed (1=Low, 2=High)
# X& = unit name (<=24 chars, [A-Z0-9-], first alpha, last not hyphen)
# --- Video Mute ---
- id: set_video_mute_output
label: Set Video Mute (single output)
kind: action
command: "X! * X@ B"
params:
- name: output
type: integer
description: "Output number (1 or 2) - SIS variable X!"
- name: status
type: integer
description: "Mute status: 0=off, 1=on - SIS variable X@"
response: "Vmt X! * X@]"
- id: set_video_mute_all
label: Set Video Mute (all outputs)
kind: action
command: "X@ B"
params:
- name: status
type: integer
description: "Mute status: 0=off, 1=on - SIS variable X@"
response: "Vmt X@]"
- id: query_video_mute
label: Query Video Mute Status
kind: query
command: "B"
params: []
response: "Vmt X@•X@]" # output1 status, output2 status
# --- Audio Mute ---
- id: set_audio_mute_output
label: Set Audio Mute (single output)
kind: action
command: "X! * X@ Z"
params:
- name: output
type: integer
description: "Output number (1 or 2) - SIS variable X!"
- name: status
type: integer
description: "Mute status: 0=off, 1=on - SIS variable X@"
response: "Amt X! * X@]"
- id: set_audio_mute_all
label: Set Audio Mute (all outputs)
kind: action
command: "X@ Z"
params:
- name: status
type: integer
description: "Mute status: 0=off, 1=on - SIS variable X@"
response: "Amt X@]"
- id: query_audio_mute
label: Query Audio Mute Status
kind: query
command: "Z"
params: []
response: "Amt X@•X@]" # output1 status, output2 status
# --- Signal Status ---
- id: request_signal_status
label: Request All Signal Status
kind: query
command: "E LS }"
params: []
response: "Sig X@ * X@•X@]" # input status * output1 status • output2 status (0=undetected, 1=detected)
# --- HDCP ---
- id: hdcp_on
label: HDCP Authorized Device On
kind: action
command: "E E1HDCP }"
params: []
response: "HdcpE1 ]"
- id: hdcp_off
label: HDCP Authorized Device Off
kind: action
command: "E E0HDCP }"
params: []
response: "HdcpE0 ]"
- id: query_hdcp_status
label: Query HDCP Authorized Device Status
kind: query
command: "E EHDCP }"
params: []
response: "X@]" # 1=on, 0=off
# --- EDID Minder ---
- id: view_edid_assignment
label: View EDID Assignment
kind: query
command: "E A*EDID }"
params: []
response: "X#]" # 1=default, 2=stored, 3=extend
- id: read_edid_hex
label: Read EDID in HEX
kind: query
command: "E R*EDID }"
params: []
response: "X$]" # up to 256 bytes of HEX (as text) from currently selected EDID
- id: view_edid_native_resolution
label: View EDID Native Resolution
kind: query
command: "E N*EDID }"
params: []
response: "X%]" # e.g. 1600x1200 @ 60Hz
# --- Video Bit Depth ---
- id: set_video_bit_depth
label: Set Video Bit Depth
kind: action
command: "E V X( BITD }"
params:
- name: bit_depth
type: integer
description: "0=Auto (default), 1=8 bit - SIS variable X("
response: "BitdV X(]"
- id: query_video_bit_depth
label: Query Video Bit Depth
kind: query
command: "E VBITD }"
params: []
response: "BitdV X(]"
# --- DDC Speed ---
- id: set_ddc_speed_output
label: Set DDC Speed (single output)
kind: action
command: "EX! * X* DDCS }"
params:
- name: output
type: integer
description: "Output number (1 or 2) - SIS variable X!"
- name: speed
type: integer
description: "1=Low (20 kbits, default), 2=High (100 kbits) - SIS variable X*"
response: "Ddcs X! * X*]"
- id: set_ddc_speed_all
label: Set DDC Speed (all outputs)
kind: action
command: "E 0* X* DDCS }"
params:
- name: speed
type: integer
description: "1=Low (20 kbits, default), 2=High (100 kbits) - SIS variable X*"
response: "Ddcs0* X*]"
- id: query_ddc_speed
label: Query DDC Speed (single output)
kind: query
command: "EX! DDCS }"
params:
- name: output
type: integer
description: "Output number (1 or 2) - SIS variable X!"
response: "Ddcs X*]" # 1=low, 2=high
# --- Unit Name ---
- id: set_unit_name
label: Set Unit Name
kind: action
command: "EX& CN }"
params:
- name: name
type: string
description: "Unit name (<=24 chars, [A-Z0-9-], first char alpha, last not hyphen) - SIS variable X&"
response: "Ipn •X&]"
- id: view_unit_name
label: View Unit Name
kind: query
command: "E CN }"
params: []
response: "X&]"
# --- Other ---
- id: request_part_number
label: Request Part Number
kind: query
command: "N"
params: []
response: "60-1221-01]"
- id: query_firmware_version
label: Query Firmware Version
kind: query
command: "Q"
params: []
response: "X^]" # firmware version with 2 decimals
- id: reset
label: Reset
kind: action
command: "E ZXXX }"
params: []
response: "Zpx ]"
- id: upload_firmware
label: Upload Firmware
kind: action
command: "E Upload }"
params: []
response: "...go" # during upload; "Upl]" when upload complete
Feedbacks
- id: video_mute_state
type: enum
values: [on, off]
description: "Per-output video mute (response Vmt X@•X@ = output1, output2)"
- id: audio_mute_state
type: enum
values: [on, off]
description: "Per-output audio mute (response Amt X@•X@ = output1, output2)"
- id: signal_status
type: enum
values: [detected, undetected]
description: "Input + output1 + output2 signal detect (response Sig X@ * X@•X@)"
- id: hdcp_state
type: enum
values: [on, off]
- id: edid_assignment
type: enum
values: [default, stored, extend]
description: "SIS X# (1=default, 2=stored, 3=extend)"
- id: edid_raw_hex
type: string
description: "Up to 256 bytes HEX (as text) from selected EDID (SIS X$)"
- id: edid_native_resolution
type: string
description: "e.g. 1600x1200 @ 60Hz (SIS X%)"
- id: video_bit_depth
type: enum
values: [auto, "8bit"]
- id: ddc_speed
type: enum
values: [low, high]
description: "1=Low (20 kbits), 2=High (100 kbits)"
- id: unit_name
type: string
- id: part_number
type: string
description: "60-1221-01"
- id: firmware_version
type: string
description: "Version with 2 decimals (SIS X^)"
Variables
# Settable parameters are exposed as Actions above (mute, bit depth, DDC speed, unit name, HDCP, reset).
# No additional continuous control variables documented.
Events
- id: startup_banner
description: >-
Unsolicited message sent when the DP DA2 is first switched on:
"(c) Copyright 2012, Extron Electronics DisplayPort DA Series, V x.xx, 60-1221-01]"
where 60-1221-01 is the part number and V x.xx is the firmware version.
- id: error_E01
description: "E01 - Invalid input channel number (too large)"
- id: error_E10
description: "E10 - Invalid command"
- id: error_E13
description: "E13 - Invalid value (too large)"
- id: error_E14
description: "E14 - Not valid for this configuration"
Macros
# No multi-step sequences documented in source.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings or interlock procedures present in source excerpt.
# NOTE (not a safety inference): firmware upload (Upload) and reset (ZXXX) are destructive
# operations per their descriptions; source does not document sequencing safeguards.
Notes
- Control transports: rear 5-pole captive screw
Remoteconnector (Tx/Rx/G) or front-panel Config USB mini-B port. Both carry SIS at 9600/8/N/1. Only one serial port may be used at a time — if the Config port is in use, the rear captive screw connector must be disconnected, and vice versa. - SIS commands are case-insensitive unless otherwise stated; no special start/end characters required beyond the
}(CR) terminator. - All unit responses terminate with CR/LF (
]). - Mute can also be triggered by hardware contact closure on
Remotepins 1 (output 1) / 2 (output 2), ground shared with RS-232 — this is hardware-level, outside the SIS protocol. - EDID source selection / output mode is set by two DIP switches; SIS EDID commands report the resulting state (default / stored / extend).
- Extend mode resolutions (per output): 1920x1080, 1680x1050, 1440x900, 1280x1024 (all @ 60 Hz).
Provenance
source_domains:
- media.extron.com
source_urls:
- https://media.extron.com/public/download/files/userman/68-2154-01_E_DP_DA2_Body.pdf
retrieved_at: 2026-07-02T20:23:52.614Z
last_checked_at: 2026-07-07T11:36:54.122Z
Verification Summary
verdict: verified
checked_at: 2026-07-07T11:36:54.122Z
matched_actions: 24
action_count: 24
confidence: medium
summary: "All 24 spec actions match verbatim against the source command table; transport parameters verified; complete coverage. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "power voltage/current specs not in source excerpt. flow_control not stated. Mute contact-closure pin behavior is hardware-level, not protocol."
- "flow control not stated in source"
- "no safety warnings or interlock procedures present in source excerpt."
- "flow_control not stated in source."
- "firmware version compatibility range not stated (reported dynamically as V x.xx)."
- "exact reset sub-modes behind \"ZXXX\" not expanded in source."