Summary

Epson CB EB PowerLite L630U is a laser projector controlled via the ESC/VP21 protocol. ESC/VP21 uses ASCII command codes transmitted over serial (RS-232C), USB, or TCP/IP. This spec covers power, mute, source selection, and query commands.

Transport

protocols:
  - serial
  - tcp
serial:
  baud_rate: 9600
  data_bits: 8
  parity: none
  stop_bits: 1
  flow_control: none
addressing:
  port: null  # UNRESOLVED: TCP port number not stated in source
auth:
  type: none  # inferred: no auth procedure in source

Traits

- powerable    # PWR ON / PWR OFF commands present
- queryable    # Get command format documented (? suffix)
- routable     # SOURCE commands for input selection present
- levelable    # INC/DEC step parameters for adjustable values

Actions

- id: power_on
  label: Power On
  kind: action
  command: "PWR ON"
  params: []

- id: power_off
  label: Power Off
  kind: action
  command: "PWR OFF"
  params: []

- id: mute_on
  label: Mute On
  kind: action
  command: "MUTE ON"
  params: []

- id: mute_off
  label: Mute Off
  kind: action
  command: "MUTE OFF"
  params: []

- id: source_select
  label: Select Source
  kind: action
  command: "SOURCE {code}"
  params:
    - name: code
      type: string
      description: "Source code (e.g. 10=cyclic input1, 11=AnalogRGB, 14=YCbCr, 15=YPbPr, 1F=Auto, 20=cyclic input2, 30=cyclic input3, 40=cyclic video, 41=video RCA, 42=video S, A0=HDMI, D0=WirelessHD)"

- id: null_command
  label: Heartbeat / Null Command
  kind: action
  command: "\\r"
  description: "Sends carriage return (0x0D). Projector responds with colon to confirm operation."
  params: []

- id: step_increment
  label: Increment Parameter
  kind: action
  command: "{param} INC"
  description: "Increments the parameter by one step."
  params:
    - name: param
      type: string
      description: "Parameter name to increment"

- id: step_decrement
  label: Decrement Parameter
  kind: action
  command: "{param} DEC"
  description: "Decrements the parameter by one step."
  params:
    - name: param
      type: string
      description: "Parameter name to decrement"

- id: step_init
  label: Initialize Parameter
  kind: action
  command: "{param} INIT"
  description: "Resets the parameter to its initial value."
  params:
    - name: param
      type: string
      description: "Parameter name to initialize"

Feedbacks

- id: power_state
  label: Power State
  type: query
  command: "PWR?"
  values: [ON, OFF]
  description: "Query current power state."

- id: mute_state
  label: Mute State
  type: query
  command: "MUTE?"
  values: [ON, OFF]
  description: "Query current mute state."

- id: source_state
  label: Current Source
  type: query
  command: "SOURCE?"
  description: "Query currently selected input source."

- id: error_response
  label: Error Response
  type: enum
  values: [ERR]
  description: "Returned when an invalid command is received. Followed by 0x0D and colon."

Variables

# UNRESOLVED: settable parameter names beyond PWR/MUTE/SOURCE not enumerated in source

Events

# No unsolicited notifications documented in source

Macros

# UNRESOLVED: no multi-step sequences described in source

Safety

confirmation_required_for: []
interlocks: []
# UNRESOLVED: source notes PWR ON may require preparation steps on some models
# (e.g. SPWRLVL 01 command, standby state requirement) - applicability to L630U unknown

Notes

  • ESC/VP21 commands are ASCII-based. Projector responds with a colon (:) after successful command execution.
  • Error responses consist of ERR followed by 0x0D and :.
  • Step parameters (INC/DEC/INIT) apply to adjustable values; specific parameter names for this model are not documented in the source.
  • Source selection uses hexadecimal codes where the first digit identifies the input group (1=INPUT1, 2=INPUT2, 3=INPUT3, 4=VIDEO, A=HDMI, C=INPUT5, D=WirelessHD) and the second digit identifies the signal type within that group (0=cyclic, F=auto).

Provenance

source_domains:
  - files.support.epson.com
source_urls:
  - https://files.support.epson.com/pdf/pltw1_/pltw1_cm.pdf
  - https://files.support.epson.com/pdf/pl600p/pl600pcm.pdf
retrieved_at: 2026-05-14T15:57:21.734Z
last_checked_at: 2026-06-02T22:06:42.095Z

Verification Summary

verdict: verified
checked_at: 2026-06-02T22:06:42.095Z
matched_actions: 9
action_count: 9
confidence: medium
summary: "All 9 spec actions traced to source (dip-safe re-verify). (11 unresolved item(s) noted in Known Gaps.)"

Known Gaps

- "CB EB PowerLite L630U not listed in the applicable models table — command set may differ from the documented home-projector models"
- "TCP/IP port number not stated in source"
- "no response format tables documented beyond colon/ERR"
- "TCP port number not stated in source"
- "settable parameter names beyond PWR/MUTE/SOURCE not enumerated in source"
- "no multi-step sequences described in source"
- "source notes PWR ON may require preparation steps on some models"
- "CB EB PowerLite L630U not in applicable model list — exact command compatibility unconfirmed"
- "TCP/IP port number for network control not stated"
- "full set of queryable parameters not enumerated"
- "response format details beyond colon/ERR not documented"