Summary
CS-Bus gateway translator supporting dual transport: RS-232-C serial and UDP over Ethernet via eNode adapter. Controls IMC-100T motor controllers and ILC-100x LED controllers via Z.G.N (Zone/Group/Node) addressing scheme. Commands are ASCII-based, dot-delimited, semicolon-terminated.
Transport
protocols:
- serial
- udp
serial:
baud_rate: 57600
data_bits: 8
parity: none # source states N parity (none = no parity)
stop_bits: 1
flow_control: none
# UNRESOLVED: RS-232 pinout / connector type not stated
addressing:
# UDP only - eNode IP assigned via DHCP or static; no port stated for IBT-100 itself
# UNRESOLVED: eNode IP addressing scheme not documented here
udp:
# Source states eNode UDP ports, not IBT-100 directly:
# UNRESOLVED: IBT-100 native UDP port not stated
auth:
type: none # inferred: no auth procedure in source
Traits
# Supported by evidence from command table:
- powerable # STOP command present for motor and LED
- routable # Z.G.N addressing provides broadcast/unicast routing
- levelable # LED SET, SAT, HUE with 0-240 range; FADE_UP/DOWN
- queryable # Q=QY returns device info
Actions
# Motor Control - Function: A or MOTOR
- id: motor_down
label: Motor Down
kind: action
params: []
description: "Command port to send motor DOWN"
examples:
- "#1.1.1.MOTOR=DOWN;"
- id: motor_up
label: Motor Up
kind: action
params: []
description: "Command port to send motor UP"
examples:
- "#1.1.1.MOTOR=UP;"
- id: motor_stop
label: Motor Stop
kind: action
params: []
description: "Command port to STOP motor"
examples:
- "#1.1.1.MOTOR=STOP;"
# LED Control (external load) - Function: L or LED
- id: led_on
label: LED On
kind: action
params: []
description: "Turns LED on to full on, or value when OFF was issued"
- id: led_off
label: LED Off
kind: action
params: []
description: "Turns LED off"
- id: led_fade_up
label: LED Fade Up
kind: action
params: []
description: "Fades brightness up continuously until STOP"
- id: led_fade_down
label: LED Fade Down
kind: action
params: []
description: "Fades brightness down continuously until STOP"
- id: led_sat_up
label: LED Saturation Up
kind: action
params: []
description: "Increases saturation (less color-more white) continuously until STOP"
- id: led_sat_down
label: LED Saturation Down
kind: action
params: []
description: "Decreases saturation (more color-less white) continuously until STOP"
- id: led_hue_up
label: LED Hue Up
kind: action
params: []
description: "Shifts hue red>yellow>green>cyan>blue>magenta continuously until STOP"
- id: led_hue_down
label: LED Hue Down
kind: action
params: []
description: "Shifts hue magenta>blue>cyan>green>yellow>red continuously until STOP"
- id: led_stop
label: LED Stop
kind: action
params: []
description: "Stops any Fades, Sat, Hue actions"
- id: led_set
label: LED Set Brightness
kind: action
params:
- name: value
type: integer
range: 0-240
description: "Brightness value 0-240. Example: SET,240"
examples:
- "#2.1.1.LED=SET,240;"
- id: led_sat_set
label: LED Set Saturation
kind: action
params:
- name: value
type: integer
range: 0-240
description: "Saturation value 0-240"
examples:
- "#2.1.1.LED=SAT,240;"
- id: led_hue_set
label: LED Set Hue
kind: action
params:
- name: value
type: integer
range: 0-240
description: "Hue value 0-240. 0=red, 80=green, 160=blue (HSL color space only)"
examples:
- "#2.1.1.LED=HUE,240;"
- id: led_store
label: LED Store Preset
kind: action
params:
- name: preset
type: integer
range: 1-6
description: "Preset slot number"
examples:
- "#0.0.0.LED=STORE,4;"
- id: led_recall
label: LED Recall Preset
kind: action
params:
- name: preset
type: integer
range: 1-6
description: "Preset slot number to recall"
examples:
- "#0.0.0.LED=RECALL,1;"
- id: led_effect
label: LED Effect
kind: action
params: []
description: "Cycles through first eight preset colors"
# On-board LED (IMC-100x) - Function: L or LED (on-board indicator)
- id: led_indicator_on
label: LED Indicator On
kind: action
params: []
description: "Turns on-board amber LED to full ON"
- id: led_indicator_off
label: LED Indicator Off
kind: action
params: []
description: "Turns on-board amber LED to full OFF"
- id: led_indicator_flash
label: LED Indicator Flash
kind: action
params: []
description: "Repeatedly flashes on-board amber LED"
Feedbacks
- id: command_echo
type: string
description: "Valid commands are echoed back. Invalid commands return '*' followed by partial command."
- id: device_info
type: string
description: "Response to Q=QY query. IMC-100 returns '99', ILC-100 returns '48'. Only responds to non-wildcard Z.G.N address."
example: "#2.1.1.Q=QY; → 99 (for IMC-100)"
Variables
# UNRESOLVED: no persistent parameter storage documented for IBT-100 itself
# LED parameters (brightness/sat/hue) are stored on target devices via STORE command
Events
# UNRESOLVED: no unsolicited event notifications documented for CS-Bus protocol
Macros
# UNRESOLVED: no multi-step macro sequences documented in source
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings or interlock procedures in source
Command Syntax Reference
# Z.G.N format: #Z.G.N.FUNCTION=COMMAND,data;
# Wildcard: #0.0.0.FUNCTION=COMMAND; (broadcast to all devices)
# Wildcard constraints: Q=QY does not respond to wildcard addresses
addressing:
zones: 0-255 # 0 = broadcast
groups: 0-255 # 0 = broadcast
nodes: 0-255 # 0 = broadcast
terminator: ";"
required_prefix: "#"
Notes
- Serial: 57600 baud, 8N1, no flow control — stated explicitly in source.
- UDP requires eNode adapter; eNode ports are 5000 (TX) and 4000 (RX) — not the IBT-100 itself.
- Command echo behavior: valid → echo back; invalid → "*" + partial command.
- Q=QY does not respond to wildcard address — requires specific Z.G.N.
- LED SET/SAT/HUE accept 0-240 range; source shows syntax
SET,240(comma, no space). - Continuous actions (FADE_UP, FADE_DOWN, HUE_UP, HUE_DOWN, SAT_UP, SAT_DOWN) ramp until STOP issued.
- Source: "Third-Party CS-Bus Programmer's Guide - ZGN Commands" Rev 1.4, Oct 2, 2009.
Provenance
source_domains:
- convergingsystems.com
source_urls:
- http://www.convergingsystems.com/bin/doc/ibt/serial_udp_v1_4.pdf
- http://www.convergingsystems.com/bin/doc/ibt/ibt_manual_0105.pdf
retrieved_at: 2026-05-21T09:15:44.261Z
last_checked_at: 2026-06-03T06:32:00.804Z
Verification Summary
verdict: verified
checked_at: 2026-06-03T06:32:00.804Z
matched_actions: 21
action_count: 21
confidence: medium
summary: "All 21 actions found and matched in source (11 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "IBT-100 is a bus translator — actual controlled devices (IMC-100T, ILC-100x) are documented separately. This spec covers the IBT-100 as the transport gateway only."
- "RS-232 pinout / connector type not stated"
- "eNode IP addressing scheme not documented here"
- "IBT-100 native UDP port not stated"
- "no persistent parameter storage documented for IBT-100 itself"
- "no unsolicited event notifications documented for CS-Bus protocol"
- "no multi-step macro sequences documented in source"
- "no safety warnings or interlock procedures in source"
- "IBT-100 firmware version compatibility not stated"
- "RS-232 connector pinout not stated"
- "UDP port for IBT-100 native Ethernet interface not stated — eNode ports (5000/4000) are for the adapter, not IBT-100 itself"