Casio XJ-S Series data projector. RS-232C serial control via YK-5 cable. ASCII command protocol at 19200bps 8N1. Read/write commands for power, input, volume, display settings; read-only lamp time.
Transport
protocols:
- serial
serial:
baud_rate: 19200
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable
- routable
- queryable
- levelable
Actions
- id: power
label: Power On/Off
kind: action
params:
- name: state
type: integer
description: 0 = Off, 1 = On
- id: src
label: Input Switching
kind: action
params:
- name: source
type: integer
description: 0=RGB, 1=Component, 2=Video, 5=USB, 6=Auto, 7=HDMI, 8=Wireless
- id: blk
label: Blank Screen
kind: action
params:
- name: state
type: integer
description: 0 = Off, 1 = On
- id: vol
label: Volume
kind: action
params:
- name: level
type: integer
description: 0 to 50 (range model-dependent)
- id: pst
label: Color Mode
kind: action
params:
- name: mode
type: integer
description: 0=Presentation, 1=Graphics, 2=Theater, 3=Standard, 4=Blackboard, 5=Game
- id: arz
label: Aspect Ratio
kind: action
params:
- name: ratio
type: integer
description: 0=Normal(RGB/HDMI), 1=16:9, 2=Normal(Video), 3=LetterBox, 4=Full, 5=True, 6=4:3
- id: ozm
label: Optical Zoom Shift
kind: action
params:
- name: dir
type: integer
description: 0=No change, 1=Wide, 2=Tele
- id: ofc
label: Optical Focus Shift
kind: action
params:
- name: dir
type: integer
description: 0=No change, 1=Near, 2=Far
- id: lmp
label: Get Lamp Time
kind: query
params: []
- id: lrt
label: Lamp Time Reset
kind: action
params:
- name: reset
type: integer
description: 0=No reset, 1=Reset (only when lamp time > 2100 hours and power off)
Feedbacks
- id: error_response
label: Error Response
description: Device returns "?" for unrecognized commands
- id: read_response
label: Read Response Format
description: Returns (setting_range,current_value) e.g. (0-50,35)
Variables
# UNRESOLVED: no continuous variable parameters found in source
Events
# UNRESOLVED: no unsolicited event notifications documented
Macros
# UNRESOLVED: no multi-step macro sequences documented
Safety
confirmation_required_for: []
interlocks:
- Wait for lamp cool-down after power off before powering on again
- Wait at least 1 minute after power on before turning power off
- Lamp time reset only when lamp hours exceed 2100 and projector is powered off
Notes
Device returns "?" for unrecognized commands. Commands outside valid range (e.g. VOL beyond max) set parameter to its maximum value. A valid input signal must be present to execute blank screen or aspect ratio commands. Some models lack Lamp Time Reset. Read/write disabled for most functions while projector is off.
Provenance
source_domains:
- support.casio.com
- manualmachine.com
source_urls:
- https://support.casio.com/pdf/007/YK-5_RS-232C_Control_E.pdf
- https://manualmachine.com/casio/rs232c/1402409-user-manual/
retrieved_at: 2026-04-30T11:49:52.748Z
last_checked_at: 2026-06-03T06:28:19.807Z
Verification Summary
verdict: verified
checked_at: 2026-06-03T06:28:19.807Z
matched_actions: 10
action_count: 10
confidence: medium
summary: "All 10 spec actions verified against source command list (7 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "which specific XJ-S models support USB/HDMI/wireless inputs not confirmed for all units"
- "no continuous variable parameters found in source"
- "no unsolicited event notifications documented"
- "no multi-step macro sequences documented"
- "specific XJ-S model variants and their supported inputs/features"
- "firmware version compatibility not stated"
- "detailed pinout of YK-5 cable not in this excerpt"