Summary
Software toolchain providing VS Code scripting access to the BSS Audio MUSE (Mojo Universal Scripting Engine) Controller. Document covers ICSP, HiQNet, and HControl device bindings, CLI commands, and Thing API used to drive downstream AV devices from scripts. Underlying control plane is TCP/IP; ICSP URL mode listens on TCP 1319 (1320 for ICSPS).
Transport
protocols:
- tcp
addressing:
port: 1319 # ICSP URL Mode default; ICSPS uses 1320
auth:
type: ssh # SSH login required for CLI on MUSE Controller
Traits
- queryable # inferred: device:parameters / device:get commands present
Actions
# UNRESOLVED: source describes programmatic API (Thing API, device:invoke) and
# a general CLI command surface, but does not enumerate device-specific
# commands for the MUSE extension itself. Concrete action payloads depend on
# attached peripheral descriptor files.
- id: device_invoke
label: Invoke Command on Device
kind: action
command: "device:invoke {instance_id} {command_name} [{arguments}]"
params:
- name: instance_id
type: string
description: Device instance id (e.g. dvDVD)
- name: command_name
type: string
description: Command path (e.g. power/0/cycle)
- name: arguments
type: string
description: "Optional name=value pairs"
- id: device_set_parameter
label: Set Device Parameter
kind: action
command: "device:set {instance_id} {parameter_path} {value}"
params:
- name: instance_id
type: string
- name: parameter_path
type: string
description: e.g. discTransport/0/discTransport
- name: value
type: string
- id: device_get_parameter
label: Get Device Parameter
kind: query
command: "device:get {instance_id} {parameter_path}"
params:
- name: instance_id
type: string
- name: parameter_path
type: string
- id: device_list
label: List Devices
kind: query
command: "device:list"
- id: device_commands
label: List Device Commands
kind: query
command: "device:commands {instance_id}"
params:
- name: instance_id
type: string
- id: device_parameters
label: List Device Parameters
kind: query
command: "device:parameters {instance_id}"
params:
- name: instance_id
type: string
- id: driver_describe
label: Describe Device Driver
kind: query
command: "driver:describe [-j] {instance_id}"
params:
- name: json
type: boolean
description: Pass -j to return raw JSON descriptor
- id: log_tail
label: Tail Log Stream
kind: query
command: "log:tail"
- id: network_ip
label: Get/Set Network IP
kind: action
command: "network:ip [options]"
params:
- name: ethinterface
type: string
description: "eth0 or eth1"
- name: mode
type: string
description: "dhcp | static | ipv6d | ipv6s"
- name: subnet
type: string
- name: gateway
type: string
- name: ip
type: string
- name: enable
type: boolean
description: Enable eth1
- name: disable
type: boolean
description: Disable eth1
Feedbacks
- id: device_online
label: Device Online State
type: boolean
description: "isOnline() / isOffline() method on Device handle; observable via .online()/.offline() callbacks"
Variables
# UNRESOLVED: parameter schema is descriptor-driven and varies per attached device.
Events
- id: parameter_update
label: Parameter Change
description: |
Delivered to .watch() callback. Fields: path (string), id (string),
value (variant), newValue (variant), oldValue (variant), normalized (float 0..1),
source (object ref).
fields:
- name: path
type: string
- name: id
type: string
- name: value
type: variant
- name: newValue
type: variant
- name: oldValue
type: variant
- name: normalized
type: float
- name: source
type: object
- id: device_event
label: Device Event
description: |
Delivered to .listen() callback. Fields: path (string), id (string),
arguments (array), oldValue (variant), source (object ref).
fields:
- name: path
type: string
- name: id
type: string
- name: arguments
type: array
- name: oldValue
type: variant
- name: source
type: object
- id: timeline_expired
label: Timeline Expired
description: |
Delivered to tickListener. tlEvent.arguments fields: sequence, time, repetition.
fields:
- name: sequence
type: integer
- name: time
type: integer
- name: repetition
type: integer
Macros
# UNRESOLVED: no multi-step sequences described.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: source contains no safety warnings or interlock procedures.
Notes
- MUSE extension is a software developer surface to the MUSE Controller; it is not a standalone controllable AV device.
- ICSP URL Mode: peripherals connect to MUSE Controller on TCP 1319 (1320 for ICSPS); controller-initiated Listen Mode uses same port.
- HControl devices: controller connects to device-selected driver com.amx.thing.hcontrol.generic; source gives no default port.
- SSH login required to reach CLI (web server, SSH, or Virtual COM via USB-C).
- Timeline service:
tick.start([times], relative, repetition)where repetition -1 = forever, 0 = once. - Parity enum example on serial port: NONE, EVEN, ODD, MARK, SPACE (default NONE).
- Serial poll example byte stream from log:tail: STX>PLYcFWD 17ETX (request) / STX >PLYsFWD 27 ETX (ack) — vendor-specific framing for downstream device, not for the MUSE extension itself.
Provenance
source_domains:
- dextra.com.mx
- amx.com
source_urls:
- https://dextra.com.mx/img/files/PRODUCTOS/AMX/05-MU-1000/Programming-Guide---AMX-MUSE.pdf
- https://www.amx.com/en/products/muse-extension-for-vscode
retrieved_at: 2026-06-30T02:59:18.902Z
last_checked_at: 2026-06-30T06:58:27.612Z
Verification Summary
verdict: verified
checked_at: 2026-06-30T06:58:27.612Z
matched_actions: 9
action_count: 9
confidence: medium
summary: "All 9 spec actions match literal CLI commands in source; TCP/SSH transport verified; complete coverage of MUSE CLI and Thing API. (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "spec describes programming interface rather than a single end-device protocol. Action surface is bound to attached peripheral descriptors, not enumerated here."
- "source describes programmatic API (Thing API, device:invoke) and"
- "parameter schema is descriptor-driven and varies per attached device."
- "no multi-step sequences described."
- "source contains no safety warnings or interlock procedures."
- "firmware/protocol version of MUSE Controller not stated. Descriptor files are device-specific; concrete action enumeration requires a target peripheral."