Summary
The FrontRow Conductor is a school-wide paging, intercom, and emergency-alert control system (hosted on a DRS5000 or DRS-VM server, default IP 192.168.1.99). This spec covers its IP-based machine control interface: HTTP REST-style endpoints for trigger scripts, calls, and alerts, plus a FrontRoom command syntax (#PAS, #AUD1, #COM1, #HTP, #NET) sent as UDP control-command actions. The Conductor can also proxy serial (#COM1) strings to attached RS-232 devices such as projectors.
Transport
protocols:
- http
- udp
- tcp # inferred: HTTP/REST transport implies TCP underly; source states IP control
addressing:
base_url: http://192.168.1.99:80/calypso/conductor # from trigger/call/alert URL examples in source
# default server IP 192.168.1.99, subnet 255.255.255.0, port 80 shown in API URL example
# port: 80 # stated in API URL example only; HTTP default
udp:
broadcast_address: x.x.x.255 # source: set last octet to 255 to broadcast to all ezRoom devices in range
port: null # UNRESOLVED: UDP port number not stated in source
auth:
type: none # inferred: API security is optional per source; default control URLs work without auth
# NOTE: optional API password security documented. When enabled, password is inserted into URL path:
# http://192.168.1.99:80/calypso/conductor/:{password}/trigger/{name} (example password: frontrow)
# NOTE: separate application/database logins exist (not the machine-control API):
# database login cserv_admin / calypso; user login admin / admin4conductor
Traits
# No standard AV traits (powerable/routable/queryable/levelable) map cleanly to the
# documented Conductor command set, which centers on paging/intercom/alert actions.
# UNRESOLVED: no power, routing, level, or query commands for the Conductor itself are documented.
Actions
# FrontRow command syntax, sent as Control Command Action Command Text over UDP, or via #NET/#HTP from networked devices.
# HTTP endpoints are REST-style GET requests to the Conductor server.
# --- FrontRoom command syntax actions ---
- id: pas_priority_alert_color
label: Priority Alert ClassLight Color
kind: action
command: '#PAS["HPS",M{n}]'
params:
- name: n
type: integer
description: Priority Alert color version (1-5); set M1..M5
notes: Displays Priority Alert colors on ClassLight-equipped ezRooms.
- id: pas_alert_off
label: ClassLight Alert Off
kind: action
command: '#PAS["OFF"]'
params: []
notes: Turns off the ClassLight alert on any/all ezRooms.
- id: aud_mute
label: Audio Mute
kind: action
command: '#AUD1[M0]'
params: []
notes: Mutes audio from a CM900. Other #AUD1 parameter values not documented in source.
- id: com1_serial_send
label: COM1 Serial Send
kind: action
command: '#COM1[T1,"{serial_string}"]'
params:
- name: serial_string
type: string
description: Serial command string to send to the device attached to the CM900 COM1 port (e.g. projector). Example 'POWR1 \r' - noted in source as example only, varies by manufacturer.
notes: Proxies a serial (RS-232) string to an attached device via the CM900 COM1 port.
- id: htp_http_command
label: HTTP Command
kind: action
command: '#HTP[{url}]'
params:
- name: url
type: string
description: Full HTTP URL to request from the Conductor server (e.g. call/alert endpoints).
notes: Used from FrontRow networked devices to issue HTTP requests.
- id: net_network_command
label: Network Command
kind: action
command: '#NET[{args}]'
params:
- name: args
type: string
description: FrontRoom network command arguments. Example CB6000 form '#NET[F1, @{CM900}, P7262, ''#COM1[T1,"POWR1 \r"]''];'.
notes: Routes a command to a networked FrontRow device. Full #NET grammar not exhaustively documented in source.
# --- HTTP REST-style endpoints ---
- id: trigger_script_invoke
label: Invoke Trigger Script
kind: action
command: 'GET http://{server}/calypso/conductor/trigger/{name}'
params:
- name: server
type: string
description: Conductor server address (default 192.168.1.99)
- name: name
type: string
description: Trigger script name (no spaces allowed)
notes: URL is loadable into CB6000/CB2000 panels or Encore/Teacher Edition; bookmarkable on smartphones. If API security enabled, insert password as /:{password}/ before /trigger/.
- id: call_request
label: Send Call Request
kind: action
command: 'GET http://{server}/calypso/conductor/call/{device_ip}'
params:
- name: server
type: string
description: Conductor server address (default 192.168.1.99)
- name: device_ip
type: string
description: IP of audio device initiating the call (omit if sender is the audio device itself, e.g. Juno Connect)
notes: Sends a call request to Conductor Notifier.
- id: send_alert
label: Send Alert
kind: action
command: 'GET http://{server}/calypso/conductor/alert/{device_ip}/{message}'
params:
- name: server
type: string
description: Conductor server address (default 192.168.1.99)
- name: device_ip
type: string
description: IP of sending audio device (optional; shown as location in Notifier)
- name: message
type: string
description: Alert text shown in Notifier window (URL-encoded; %20 = space)
notes: Sends an alert to Conductor Notifier.
Feedbacks
# UNRESOLVED: source documents no response/acknowledgement strings or queryable state values
# for the Conductor control interface. Notifier-window display is a UI behavior, not a machine feedback.
Variables
# UNRESOLVED: no settable scalar parameters documented for the machine-control interface.
# Command parameters (e.g. PAS color index M1..M5) are enumerated action params, not device variables.
Events
# Conductor Notifier RECEIVES call requests and alerts (inbound HTTP to /call/ and /alert/),
# but the source does not document unsolicited notifications EMITTED by the Conductor to controllers.
# UNRESOLVED: no outbound event/notification protocol documented.
Macros
# Source describes "Trigger Scripts" as named super-macros combining one or more Actions
# (Control Command, Pause, System Command, Play Audio Sequence, Intercom, P.A., Email).
# These are user-defined at runtime via the Conductor UI, not fixed documented sequences.
# UNRESOLVED: no fixed/built-in macro sequences documented verbatim in source.
Safety
confirmation_required_for: []
interlocks: []
# NOTE: source mentions emergency/alert use cases (LOCKDOWN trigger scripts, relay pulse to
# automated locking systems, Priority Alerts) but documents NO explicit safety interlocks,
# power-on sequencing, or confirmation procedures for the control interface.
# UNRESOLVED: no safety/interlock procedures stated in source.
Notes
- Default server IP is 192.168.1.99, subnet 255.255.255.0; all Conductor audio-over-IP devices must share the same IP range. Default configuration-computer static IPs: 192.168.1.100 or 192.168.1.98.
- Control Command Actions support sending to a specified IP address; broadcast to all ezRooms by setting the last octet to 255.
- Trigger-script names cannot contain spaces.
- At least one Master device (e.g. CM900) is required for PA/Intercom. PTT mic (CB-65/CB-75) switches must be set to Momentary + PTT; recommended GPI Mode "Rotary + Button", Push-to-Talk Mode "Always (Never Handsfree)".
- Conductor can send text patterns to FrontRow Encore PCs for fullscreen pop-up alerts; firewall must allow inbound to Encore's receive port.
- Input said RS-232C but source docs HTTP/UDP control; serial only proxied via `#COM1` → flagged unresolved.
- Port 80 only from one URL example; UDP port not stated → null + UNRESOLVED.
- No voltage/power/firmware/protocol-version values invented.
- 9 distinct actions enumerated (6 FrontRoom commands + 3 HTTP endpoints), params shown verbatim from source.
## Provenance
```yaml
source_domains:
- boxlight.com
source_urls:
- https://boxlight.com/files/library/files/Documentation-and-support-pdfs/Audio-Setup-Guides/FrontRow-Conductor-Setup-Guide-1550-00002.pdf
- https://boxlight.com/files/library/files/Documentation-and-support-pdfs/Audio-Setup-Guides/FrontRow-Conductor-Alert-and-Response-Setup-Guide.pdf
retrieved_at: 2026-06-30T11:39:14.328Z
last_checked_at: 2026-07-07T11:04:07.360Z
```
## Verification Summary
```yaml
verdict: verified
checked_at: 2026-07-07T11:04:07.360Z
matched_actions: 9
action_count: 9
confidence: medium
summary: "All 9 spec actions matched exactly against source control commands; HTTP and UDP endpoints fully documented with literal syntax. (11 unresolved item(s) noted in Known Gaps.)"
```
## Known Gaps
```yaml
- "input hint specified RS-232C, but the source documents network (HTTP/UDP) control of the Conductor itself; serial is only referenced as a proxied output to attached devices via #COM1. No direct RS-232 control OF the Conductor is documented."
- "specific UDP port for Control Command Actions not stated (broadcast to x.x.x.255 noted, port number absent)."
- "response/acknowledgement formats for commands not documented."
- "UDP port number not stated in source"
- "no power, routing, level, or query commands for the Conductor itself are documented."
- "source documents no response/acknowledgement strings or queryable state values"
- "no settable scalar parameters documented for the machine-control interface."
- "no outbound event/notification protocol documented."
- "no fixed/built-in macro sequences documented verbatim in source."
- "no safety/interlock procedures stated in source."
- "Encore receive port, exact #NET/#AUD1 grammar variants, UDP control port, and response formats are not stated in the source."
```
---