Summary
Aurora Dxci 1 Sdi G4 SDI matrix/router controlled via RS-232 (main control port) or LAN via Telnet. Spec covers the serial/Telnet ASCII command set: input-to-output routing, presets, per-port serial and HDCP configuration, IP/TCP settings, main RS-232 setup, and status queries. Commands use ! prefix (action), ? prefix (query), ~ prefix (response), each terminated by <CR> (0x0D).
Transport
# Source documents RS-232 as "Main Control Port" and LAN "via Telnet commands".
# Same ASCII command set applies to both interfaces.
protocols:
- serial
- tcp
serial:
baud_rate: 115200 # recommended per source ("Recommended baud rate is 115k 8N1"); example 115200-8-1-N-O; configurable, max 115kbps
data_bits: 8
parity: none
stop_bits: 1
flow_control: null # UNRESOLVED: flow control not stated in source (the "O" in "115200-8-1-N-O" denotes RX on, not flow control)
addressing:
port: null # UNRESOLVED: default TCP port not explicitly stated; 1001 appears in !TcpPort command example and is user-configurable
base_url: null # N/A for serial/Telnet
auth:
type: none # inferred: no auth procedure documented for RS-232/Telnet control interface (web server has separate user/123456 creds)
Traits
# - routable (input->output route command !Rxtoz present)
# - queryable (many ? queries returning state present)
traits:
- routable
- queryable
Actions
# All 38 distinct command-bearing rows from SERIAL COMMANDS table.
# `!` = action command, `?` = query command (kind: query). Each terminated by <CR> (0x0D).
# Timing: wait >= 250ms between commands (firmware v2.2.6 and above).
# --- Action commands (!) ---
- id: route
label: Route Input to Output
kind: action
command: "!Rxtoz<CR>"
params:
- name: x
type: integer
description: "input port number (0-16; 0 = unroute)"
- name: z
type: string
description: "output port number(s) (1-16); comma-separated for multiple, e.g. 1,4,5"
- id: preset_recall
label: Recall Preset
kind: action
command: "!Px<CR>"
params:
- name: x
type: integer
description: "preset number (1-9)"
- id: preset_save
label: Save Preset
kind: action
command: "!Sx<CR>"
params:
- name: x
type: integer
description: "preset number (1-9)"
- id: baud_rate_setup_input
label: Set Input Card Baud Rate
kind: action
command: "!BRabINx<CR>"
params:
- name: a
type: string
description: "baud rate (2400, 4800, 9600, 19200, 38400)"
- name: b
type: string
description: "bits/parity/stop (8N1, 8E1, 8O1)"
- name: x
type: string
description: "input port number(s) (1-16), space-separated for multiple"
- id: baud_rate_setup_output
label: Set Output Card Baud Rate
kind: action
command: "!BRabOUTx<CR>"
params:
- name: a
type: string
description: "baud rate (2400, 4800, 9600, 19200, 38400)"
- name: b
type: string
description: "bits/parity/stop (8N1, 8E1, 8O1)"
- name: x
type: string
description: "output port number(s) (1-16), space-separated for multiple"
- id: serial_rx_input
label: Set Input Card Serial Receive
kind: action
command: "!RXaINx<CR>"
params:
- name: a
type: string
description: "OFF or ON"
- name: x
type: string
description: "input port number(s) (1-16), space-separated for multiple"
- id: serial_rx_output
label: Set Output Card Serial Receive
kind: action
command: "!RXaOUTx<CR>"
params:
- name: a
type: string
description: "OFF or ON"
- name: x
type: string
description: "output port number(s) (1-16), space-separated for multiple"
- id: serial_transmit_input
label: Serial Transmit to Input Port
kind: action
command: "!RSINxTXnns<CR>"
params:
- name: x
type: string
description: "input port number(s) (1-16), space-separated for multiple"
- name: nn
type: string
description: "byte count for string (00-99), double-digit ASCII, leading zero required"
- name: s
type: string
description: "ASCII string; non-printable chars allowed (URL-encoded, e.g. %0D = 0x0D counts as 1 byte)"
- id: serial_transmit_output
label: Serial Transmit to Output Port
kind: action
command: "!RSOUTxTXnns<CR>"
params:
- name: x
type: string
description: "output port number(s) (1-16), space-separated for multiple"
- name: nn
type: string
description: "byte count for string (00-99), double-digit ASCII, leading zero required"
- name: s
type: string
description: "ASCII string; non-printable chars allowed (URL-encoded, e.g. %0D = 0x0D counts as 1 byte)"
- id: hdcp_input_negotiation
label: Set HDCP Input Negotiation
kind: action
command: "!HDCPyINx<CR>"
params:
- name: y
type: string
description: "A = normal HDCP operation; W = HDCP disabled"
- name: x
type: string
description: "input port number(s) (1-16), space-separated for multiple"
- id: hdcp_forced_output
label: Set HDCP Forced Output
kind: action
command: "!HDCPyOUTx<CR>"
params:
- name: y
type: string
description: "A = output HDCP follows routed input; W = force HDCP on for faster switching"
- name: x
type: string
description: "output port number(s) (1-16), space-separated for multiple"
- id: set_ip_address
label: Set Main MCU IP Address
kind: action
command: "!IP:x<CR>"
params:
- name: x
type: string
description: "IP address in form xxx.xxx.xxx.xxx"
- id: set_subnet_mask
label: Set Main MCU Subnet Mask
kind: action
command: "!Mask:x<CR>"
params:
- name: x
type: string
description: "subnet mask in form xxx.xxx.xxx.xxx"
- id: set_gateway
label: Set Main MCU Gateway
kind: action
command: "!Gate:x<CR>"
params:
- name: x
type: string
description: "gateway in form xxx.xxx.xxx.xxx"
- id: set_tcp_port
label: Set Main MCU TCP Port
kind: action
command: "!TcpPort:x<CR>"
params:
- name: x
type: integer
description: "TCP port number"
- id: set_tcp_protocol
label: Set TCP Server or Client
kind: action
command: "!TcpProtocol:x<CR>"
params:
- name: x
type: string
description: "Server or Client"
- id: set_main_baud
label: Set Main RS-232 Baud Rate
kind: action
command: "!MBaud:x<CR>"
params:
- name: x
type: integer
description: "baud rate (9600, 19200, 38400, 57600, 115200)"
- id: set_main_data_bits
label: Set Main RS-232 Data Bits
kind: action
command: "!MDBits:x<CR>"
params:
- name: x
type: integer
description: "7 or 8"
- id: set_main_stop_bits
label: Set Main RS-232 Stop Bits
kind: action
command: "!MSBits:x<CR>"
params:
- name: x
type: integer
description: "1 or 2"
- id: set_main_parity
label: Set Main RS-232 Parity
kind: action
command: "!MParity:x<CR>"
params:
- name: x
type: string
description: "None, Even, or Odd"
# --- Query commands (?) ---
- id: query_hot_plug
label: Query Hot Plug
kind: query
command: "?HPx<CR>"
params:
- name: x
type: string
description: "IN or OUT"
- id: query_input_card_baud
label: Query Input Card Baud Rate
kind: query
command: "?BRINx<CR>"
params:
- name: x
type: string
description: "input port number(s) (1-16), space-separated for multiple"
- id: query_output_card_baud
label: Query Output Card Baud Rate
kind: query
command: "?BROUTx<CR>"
params:
- name: x
type: string
description: "output port number(s) (1-16), space-separated for multiple"
- id: query_input_card_serial_rx
label: Query Input Card Serial Receive
kind: query
command: "?RXINx<CR>"
params:
- name: x
type: string
description: "input port number(s) (1-16), space-separated for multiple"
- id: query_output_card_serial_rx
label: Query Output Card Serial Receive
kind: query
command: "?RXOUTx<CR>"
params:
- name: x
type: string
description: "output port number(s) (1-16), space-separated for multiple"
- id: query_firmware_input_card
label: Query Firmware Input Card
kind: query
command: "?FMINx<CR>"
params:
- name: x
type: integer
description: "port number (1-4)"
- id: query_firmware_output_card
label: Query Firmware Output Card
kind: query
command: "?FMOUTCx<CR>"
params:
- name: x
type: integer
description: "port number (1-4)"
- id: query_firmware_main
label: Query Firmware Main Processor
kind: query
command: "?FM0<CR>"
params: []
notes: "0 is default for main processor firmware query"
- id: query_input_route
label: Query Input Route
kind: query
command: "?RINx<CR>"
params:
- name: x
type: integer
description: "input port number (1-16); response lists all outputs the input is routed to (space-separated)"
- id: query_ip_address
label: Query Main MCU IP Address
kind: query
command: "?IP<CR>"
params: []
- id: query_subnet_mask
label: Query Subnet Mask
kind: query
command: "?Mask<CR>"
params: []
- id: query_gateway
label: Query Gateway
kind: query
command: "?Gate<CR>"
params: []
- id: query_tcp_port
label: Query TCP Port
kind: query
command: "?TcpPort<CR>"
params: []
- id: query_tcp_protocol
label: Query TCP Server or Client
kind: query
command: "?TcpProtocol<CR>"
params: []
- id: query_main_baud
label: Query Main RS-232 Baud Rate
kind: query
command: "?MBaud<CR>"
params: []
- id: query_main_data_bits
label: Query Main RS-232 Data Bits
kind: query
command: "?MDBits<CR>"
params: []
- id: query_main_stop_bits
label: Query Main RS-232 Stop Bits
kind: query
command: "?MSBits<CR>"
params: []
- id: query_main_parity
label: Query Main RS-232 Parity
kind: query
command: "?MParity<CR>"
params: []
Feedbacks
# Device echoes each successful command back as a response using ~ prefix, same case as command (e.g. !R5to1,2,3,4 -> ~R5to1,2,3,4).
- id: command_ack
type: string
description: "Echo of issued command with ~ prefix and same case; confirms command received/executed"
- id: hot_plug_state
type: string
description: "Response to ?HPIN/<CR>; per-port hot-plug state as digit string, e.g. ~HPIN1000010000<CR>"
Variables
# No settable continuous parameters beyond the discrete actions above.
# UNRESOLVED: no continuous variables (volume/gain/brightness) documented in source.
Events
# Unsolicited: serial strings received on input/output card ports are forwarded to the main RS-232 bus when that port's RX is ON, framed as ~RS{x}TX{nn}{string}<CR>. Example from DXW-2 wall plate button press: ~RSIN1TX05~BP1<CR>.
- id: serial_port_receive_forward
type: string
description: "Forwarded serial receive from a card port; format ~RS{IN|OUT}{ports}TX{bytecount}{string}<CR>"
Macros
# UNRESOLVED: no multi-step sequences described explicitly in source.
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings, interlock procedures, or power-on sequencing requirements stated in source.
Notes
- Command prefix convention:
!= action command,?= query command,~= response. All case-sensitive. All responses mirror the case of the issued command. - Every command/query terminated by
<CR>(carriage return, hex 0x0D / decimal 13). - Timing: wait at least 250ms between commands on firmware v2.2.6 and above.
- RS-232 connector: DB-9 Female. Pin 2 = TX, Pin 3 = RX, Pin 5 = GND.
- Recommended serial config 115200 8N1; main RS-232 params (baud/data/stop/parity) are runtime-configurable via front panel or the
!MBits/!MSBits/!MParity/!MBaudcommands. Max baud 115kbps. - Card-level RS-232 baud/format independently configurable per input/output port via
!BR...INx/!BR...OUTx. - Default web-server IP 192.168.2.175, subnet 255.255.255.0, web login user/
123456. These are web-server credentials, separate from the control interface (which has no documented auth). - Serial transmit byte count (
nn) must be double-digit ASCII with leading zero; URL-encoded hex (e.g.%0D) counts as a single byte toward the count.
Provenance
source_domains:
- web.archive.org
source_urls:
- https://web.archive.org/web/2018/https://auroramultimedia.com/assets/2016/05/DXM-G3-Series-Users-Guide-160515.pdf
retrieved_at: 2026-07-01T05:33:46.441Z
last_checked_at: 2026-07-07T11:00:12.224Z
Verification Summary
verdict: verified
checked_at: 2026-07-07T11:00:12.224Z
matched_actions: 38
action_count: 38
confidence: medium
summary: "All 38 spec actions matched literally against source table; baud/parity/stop-bit/protocol transport parameters verified; one-to-one command coverage. (9 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "source document is titled \"DXM G3 Series\" rear-panel / serial commands; exact model match to Dxci 1 Sdi G4 not confirmed in source text."
- "default TCP control port not explicitly stated; flow control not stated; firmware compatibility range not stated."
- "flow control not stated in source (the \"O\" in \"115200-8-1-N-O\" denotes RX on, not flow control)"
- "default TCP port not explicitly stated; 1001 appears in !TcpPort command example and is user-configurable"
- "no continuous variables (volume/gain/brightness) documented in source."
- "no multi-step sequences described explicitly in source."
- "no safety warnings, interlock procedures, or power-on sequencing requirements stated in source."
- "source text references \"DXM G3 Series\" rear panel and DXW-2 wall plate; model correspondence to \"Dxci 1 Sdi G4\" not explicitly stated in source."
- "default TCP control port not stated (1001 only in example); flow control not stated; firmware version compatibility range not stated."