Summary
Zone pre-amp / mixer with 2 zones, each supporting music level, microphone level, and source selection. RS-232 serial control at 19200 baud 8-N-1. ASCII command protocol with structured SET/GET/INC/DEC commands plus preset store/recall and Easywave RF integration. Autonomous feedback when VALFB is enabled.
Transport
protocols:
- serial
serial:
baud_rate: 19200 # default; configurable to 2400, 4800, 9600 via BAUDRATE command
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # POWER DOWN! event on power loss
- queryable # GET commands return attribute values
- levelable # MSCLVL, MICLVL, MIN/MAX limits support SET/INC/DEC
- routable # SELECT attribute switches source A/B/C/D per zone
Actions
- id: set_attribute
label: Set Attribute
kind: action
params:
- name: attribute
type: enum
values:
- MSCLVL
- MICLVL
- SELECT
- MINMSC
- MAXMSC
- MINMIC
- MAXMIC
- ECHO
- CR
- BS
- RESPONSE
- BAUDRATE
- DBLCLICK
- RFKEY
- VALFB
- name: zone
type: enum
values:
- ZONE1
- ZONE2
description: Zone target (required for MSCLVL, MICLVL, SELECT, MIN/MAX variants)
- name: value
type: union
description: Numeric 0-100 for level attributes; A/B/C/D for SELECT; ON/OFF for settings; SELECT/PRESET for RFKEY
- id: get_attribute
label: Get Attribute
kind: action
params:
- name: attribute
type: enum
values:
- MSCLVL
- MICLVL
- SELECT
- MINMSC
- MAXMSC
- MINMIC
- MAXMIC
- RFKEY
- INFO
- SERIAL
- HWVRSN
- SWVRSN
- name: zone
type: enum
values:
- ZONE1
- ZONE2
description: Required for zone-scoped attributes
- id: increase
label: Increment Attribute
kind: action
params:
- name: attribute
type: enum
values:
- MSCLVL
- MICLVL
- MINMSC
- MAXMSC
- MINMIC
- MAXMIC
- name: zone
type: enum
values:
- ZONE1
- ZONE2
- name: delta
type: integer
description: Increment amount (defaults to 1 if omitted)
- id: decrease
label: Decrement Attribute
kind: action
params:
- name: attribute
type: enum
values:
- MSCLVL
- MICLVL
- MINMSC
- MAXMSC
- MINMIC
- MAXMIC
- name: zone
type: enum
values:
- ZONE1
- ZONE2
- name: delta
type: integer
description: Decrement amount (defaults to 1 if omitted)
- id: recall_preset
label: Recall Preset
kind: action
params:
- name: zone
type: enum
values:
- ZONE1
- ZONE2
- null
description: Optional zone; null = both zones
- name: number
type: integer
description: Preset number 0-64
- id: store_preset
label: Store Preset
kind: action
params:
- name: zone
type: enum
values:
- ZONE1
- ZONE2
- null
description: Optional zone; null = both zones
- name: number
type: integer
description: Preset number 1-64
- id: clear_preset
label: Clear Preset(s)
kind: action
params:
- name: number
type: union
description: Preset number 1-64 or "ALL" to clear all
- id: learn_rf
label: Learn Easywave RF Switch
kind: action
params:
- name: zone
type: enum
values:
- ZONE1
- ZONE2
- id: clear_rf
label: Clear Easywave RF Switches
kind: action
params:
- name: target
type: enum
values:
- ALL
- id: help
label: List Commands and Attributes
kind: action
params: []
description: HELP or LST - both produce identical output listing all commands and attributes
Feedbacks
- id: level_feedback
label: Level Change Feedback
type: string
pattern: "{ATTR} {ZONE} {VALUE}"
description: Emitted when VALFB is on and any control changes. E.g. "MSCLVL ZONE1 75"
- id: remote_state
label: Remote Mode State
type: string
pattern: "REMOTE ZONEx {0|1}"
description: Emitted when REMOTE select on PM1122 is toggled. 0 = local, 1 = remote.
- id: power_down
label: Power Down
type: string
value: "POWER DOWN!"
description: Emitted when device loses power.
- id: info_response
label: INFO Response
type: string
description: Multi-line response to GET INFO listing all controls and values. Split across multiple receive packets; parse by splitting on \r\n.
- id: preset_recall_response
label: Preset Recall Acknowledgement
type: string
description: Device echoes STR/RCL command string back as confirmation.
- id: attribute_value
label: Attribute Value Response
type: string
pattern: "{ATTR} {ZONE} {VALUE}"
description: Response to GET commands returning attribute current value.
Variables
# Level limits are settable and persist per zone:
- id: min_msc_zone1
label: Minimum Music Level Z1
type: integer
range: [0, 100]
default: 0
- id: max_msc_zone1
label: Maximum Music Level Z1
type: integer
range: [0, 100]
default: 100
- id: min_mic_zone1
label: Minimum Microphone Level Z1
type: integer
range: [0, 100]
default: 0
- id: max_mic_zone1
label: Maximum Microphone Level Z1
type: integer
range: [0, 100]
default: 100
- id: min_msc_zone2
label: Minimum Music Level Z2
type: integer
range: [0, 100]
default: 0
- id: max_msc_zone2
label: Maximum Music Level Z2
type: integer
range: [0, 100]
default: 80 # observed default in INFO response
- id: min_mic_zone2
label: Minimum Microphone Level Z2
type: integer
range: [0, 100]
default: 0
- id: max_mic_zone2
label: Maximum Microphone Level Z2
type: integer
range: [0, 100]
default: 100
- id: source_select_zone1
label: Source Selection Z1
type: enum
values: [A, B, C, D]
- id: source_select_zone2
label: Source Selection Z2
type: enum
values: [A, B, C, D]
- id: music_level_zone1
label: Music Level Z1
type: integer
range: [0, 100]
- id: music_level_zone2
label: Music Level Z2
type: integer
range: [0, 100]
- id: mic_level_zone1
label: Microphone Level Z1
type: integer
range: [0, 100]
- id: mic_level_zone2
label: Microphone Level Z2
type: integer
range: [0, 100]
- id: valfb
label: Autonomous Value Feedback
type: boolean
description: When ON, device sends level_feedback on every control change
- id: echo_mode
label: Echo Received Characters
type: boolean
- id: cr_mode
label: CR Termination Mode
type: boolean
description: OFF = \n only, ON = \n\r
- id: bs_mode
label: Backspace Echo Mode
type: boolean
- id: response_mode
label: Command Response Mode
type: boolean
description: When OFF, device sends no reply to commands
- id: baudrate
label: Serial Baud Rate
type: enum
values: [2400, 4800, 9600, 19200]
default: 19200
- id: dblclick_mute
label: Easywave Double-Click Mute
type: boolean
- id: rfkey_mode
label: RF Key Mode
type: enum
values: [SELECT, PRESET]
description: Whether A-D buttons select source or recall preset
- id: serial_number
label: Serial Number
type: string
read_only: true
- id: hardware_version
label: Hardware Version
type: string
read_only: true
- id: software_version
label: Software Version
type: string
read_only: true
Events
- id: power_down_event
label: Power Down
type: string
value: "POWER DOWN!"
description: Sent when device loses AC power.
- id: remote_state_event
label: Remote State Change
type: string
pattern: "REMOTE {ZONE} {0|1}"
description: Sent when REMOTE select on PM1122 panel is toggled. 1 = remote mode active.
- id: control_change_event
label: Control Value Changed
type: string
pattern: "{ATTR} {ZONE} {VALUE}"
description: Sent whenever a control changes (level, source, etc.) when VALFB is ON.
Macros
- id: store_preset_both_zones
label: Store Preset Both Zones
description: |
Stores current state of both zones as a preset.
Example sequence:
SET SELECT ZONE1 <source><CR>
SET MSCLVL ZONE1 <level><CR>
SET MICLVL ZONE1 <level><CR>
SET SELECT ZONE2 <source><CR>
SET MSCLVL ZONE2 <level><CR>
SET MICLVL ZONE2 <level><CR>
STR PRESET <number><CR>
params:
- name: zone1_source
type: enum
values: [A, B, C, D]
- name: zone1_music
type: integer
- name: zone1_mic
type: integer
- name: zone2_source
type: enum
values: [A, B, C, D]
- name: zone2_music
type: integer
- name: zone2_mic
type: integer
- name: preset_number
type: integer
- id: recall_preset_both
label: Recall Preset Both Zones
params:
- name: preset_number
type: integer
- id: clear_all_presets
label: Clear All Presets
description: "CLR PRESET ALL<CR>"
Safety
confirmation_required_for: []
interlocks: []
# UNRESOLVED: no safety warnings or interlock procedures in source
Notes
- Command terminator is Carriage Return (, ASCII 13). Line feed () ignored.
- All commands are case-insensitive ASCII strings.
- String format:
COMMAND ATTRIBUTE [ZONE] [VALUE]<CR> - SET/GET/INC/DEC require space-separated parameters.
- Only baud rate is user-configurable; data bits, parity, stop bits, flow control are fixed at 8-N-1-none.
- BAUDRATE SET command accepts 2400, 4800, 9600, 19200. 19200 is factory default.
- Autonomous feedback (VALFB) must be explicitly enabled via
SET VALFB ON<CR>. - INFO response spans multiple receive packets — parse by splitting on
\r\n. - Easywave RF features require external hardware (optional receiver module).
- RSRFFU attribute is reserved and has no function.
- RS232 pinout: Pin 2 (TX), Pin 3 (RX), Pin 5 (GND). Straight-through cable.
- Preset 0 is factory reset (all levels minimum, source A) — recall-only, cannot be stored or cleared.
- Presets 1-12 can be recalled via rear-panel contacts; presets 1-4 and 7-10 via Easywave RF (if configured).
- INFO command requires VALFB enabled to produce a response.
Provenance
source_domains:
- apart-audio.info
- manualslib.com
source_urls:
- https://apart-audio.info/cat/predv_usiliteli/pm1122/pm1122-int/PM1122-INT_Manual_eng.pdf
- https://www.manualslib.com/manual/1564403/Apart-Pm1122-Int.html
retrieved_at: 2026-04-26T17:12:12.122Z
last_checked_at: 2026-07-12T08:45:02.677Z
Verification Summary
verdict: verified
checked_at: 2026-07-12T08:45:02.677Z
matched_actions: 10
action_count: 10
confidence: medium
summary: "All 10 spec actions found in source with correct parameter enums and transport values verified. (4 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "no REST, TCP, or IP control described — serial-only device"
- "no safety warnings or interlock procedures in source"
- "voltage/current/power specifications not stated in source"
- "firmware version compatibility ranges not stated in source"
From the AI4AV catalog (https://ai4av.net) · ODbL-1.0