Summary
RS232-controlled radio tuner. Complete command set via serial. Default baud 19200, supports 2400–38400. Stereo/AM/FM operation, preset storage, RDS reception.
Transport
protocols:
- serial
serial:
baud_rate: 19200
data_bits: 8
parity: none
stop_bits: 1
flow_control: none
auth:
type: none # inferred: no auth procedure in source
Traits
- powerable # standby command present
- routable # preset recall/store present
- queryable # get info, get rdsinf commands present
- levelable # frequency tuning, volume-related commands present
Actions
- id: set_echo
label: Set Echo
kind: action
params:
- name: state
type: enum
values: [on, off]
- id: set_standby
label: Set Standby
kind: action
params:
- name: state
type: enum
values: [on, off]
- id: set_baudrate
label: Set Baud Rate
kind: action
params:
- name: rate
type: enum
values: [2400, 4800, 9600, 19200, 38400]
- id: get_info
label: Get Info
kind: action
params: []
- id: rcl_preset
label: Recall Preset
kind: action
params:
- name: preset
type: integer
description: Preset number (1-based)
- id: str_preset
label: Store Preset
kind: action
params:
- name: preset
type: integer
description: Preset number (1-based)
- id: set_mantun
label: Set Manual Tune
kind: action
params:
- name: frequency
type: number
description: Frequency in MHz (e.g. 100.90)
- id: set_stereo
label: Set Stereo
kind: action
params:
- name: state
type: enum
values: [on, off]
- id: inc_search
label: Increment Search
kind: action
params: []
- id: dec_search
label: Decrement Search
kind: action
params: []
- id: set_modula
label: Set Modulation
kind: action
params:
- name: band
type: enum
values: [AM, FM]
- id: inc_mantun
label: Increment Manual Tune
kind: action
params: []
- id: dec_mantun
label: Decrement Manual Tune
kind: action
params: []
- id: get_rdsinf_ps
label: Get RDS Station Name
kind: action
params: []
- id: get_rdsinf_rt
label: Get RDS Radio Text
kind: action
params: []
Feedbacks
# UNRESOLVED: response strings not documented in source
Variables
# UNRESOLVED: no persistent parameters documented
Events
# UNRESOLVED: no unsolicited notifications documented
Macros
# UNRESOLVED: no multi-step sequences documented
Safety
confirmation_required_for: []
interlocks: []
Notes
Default serial settings: baud 19200, echo on, CR on, BS on, valfb on. Frequency step: FM 50 kHz, AM 9 kHz. Commands not in list are unsupported.
Provenance
source_domains:
- apart-audio.info
source_urls:
- https://apart-audio.info/cat/istochniki_signalov/pr1000/PR1000R_Manual_eng.pdf
retrieved_at: 2026-04-30T04:34:45.173Z
last_checked_at: 2026-06-02T21:39:43.406Z
Verification Summary
verdict: verified
checked_at: 2026-06-02T21:39:43.406Z
matched_actions: 15
action_count: 15
confidence: medium
summary: "Complete RS232 protocol with all tuner control and preset commands specified (6 unresolved item(s) noted in Known Gaps.)"
Known Gaps
- "model name not stated in source"
- "response strings not documented in source"
- "no persistent parameters documented"
- "no unsolicited notifications documented"
- "no multi-step sequences documented"
- "device model name not stated in source"